Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1680677.1
Update Date:2014-12-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1680677.1 :   Prerequisite Brocade firmware for D/H02.18 and higher microcode  


Related Items
  • Sun StorageTek VSM4 System
  •  
  • Sun StorageTek VSM5 System
  •  
  • Sun StorageTek VSM4 System
  •  
  • Sun StorageTek VSM5 System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
  •  




In this Document
Symptoms
Changes
Cause
Solution


Applies to:

Sun StorageTek VSM5 System - Version All Versions to All Versions [Release All Releases]
Sun StorageTek VSM4 System - Version All Versions to All Versions [Release All Releases]
Sun StorageTek VSM5 System
Sun StorageTek VSM4 System
Information in this document applies to any platform.

Symptoms

 Upgrading to D/H02.18 microcode on the VSM4, VSM5 or VSM5C products can result in a significant degradation of recall performance for recalls being performed via a Brocade switch.

 Normal recall rates can be in the 18MB/s range but this problem can result in recall rates dropping to as low as about 1.9MB/s.

Changes

 An upgrade to D/H02.18 code has been done.

Cause

 Older levels of Brocade firmware have an identified bug in the Brocade ‘Tape Pipelining’ feature that results in degraded legacy VSM recall performance.  This is addressed in more recent Brocade firmware.

Solution

 When using Brocade switches, Brocade FOS Firmware v7.2.0d or higher is now a prerequisite to upgrading to D/H02.18 microcode. 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.