![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1680677.1 : Prerequisite Brocade firmware for D/H02.18 and higher microcode
In this Document
Applies to:Sun StorageTek VSM5 System - Version All Versions to All Versions [Release All Releases]Sun StorageTek VSM4 System - Version All Versions to All Versions [Release All Releases] Sun StorageTek VSM5 System Sun StorageTek VSM4 System Information in this document applies to any platform. SymptomsUpgrading to D/H02.18 microcode on the VSM4, VSM5 or VSM5C products can result in a significant degradation of recall performance for recalls being performed via a Brocade switch. Normal recall rates can be in the 18MB/s range but this problem can result in recall rates dropping to as low as about 1.9MB/s. ChangesAn upgrade to D/H02.18 code has been done. CauseOlder levels of Brocade firmware have an identified bug in the Brocade ‘Tape Pipelining’ feature that results in degraded legacy VSM recall performance. This is addressed in more recent Brocade firmware. SolutionWhen using Brocade switches, Brocade FOS Firmware v7.2.0d or higher is now a prerequisite to upgrading to D/H02.18 microcode. Attachments This solution has no attachment |
||||||||||||||||||
|