In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-7354065201>

Applies to:

Sun StorageTek VSM5 System - Version All Versions and later
Sun StorageTek VSM4 System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Cannot do Guided Fru Replacement (GFR) on a Power Distribution Unit (PDU) after loosing AC input.

Cause

 

Lost AC input from the customer environment

The VSM Power Distribution Unit (PDU) is faulty

GFR no replace is not clearing the fenced PDU due to ISP (VSM Support Processor card) requiring to be switched

Solution

 Steps to clear a fenced PDU after AC power is lost.

1. Check with the customer and insure that the  AC power is back.

2. The following steps needs to be done by a Oracle field engineer, open a service request.

3. Do a GFR, No Replace of the failing PDU.

4. If the GFR fails, the ISP may need to be switched to standby and then back to primary ISP.

5. If the ISP switch does not help, the PDU may be faulty.  Make a new task on the existing SR, and order a replacement PDU.

References

<NOTE:1306541.1> - How to Remove and Replace a VSM Fenced FRU:ATR:897:4