![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1460028.1 : VSM - VTSS event log filliing up with FSCD0A0 and FSCD123
Trouble shooting FSC D0A0 and or D123 In this Document
Created from <SR 3-5720576221> Applies to:Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]Information in this document applies to any platform. SymptomsVTSS event log filling up with FSCD0A0 and FSCD123 CauseVTSS microcode D02.12.08.xx is incorrectly logging many FSCD0A0 FSCD123 events. The VTSS has IFF3 cards and active IP links to another VTSS and or VLE. SolutionD02.14.32.00 microcode minimizes the number of these FSCs.