FSC3E40 Subsystem is out of Conditional Capacity
Related Items |
- Sun StorageTek VSM System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VSM
- _Old GCS Categories>Announcements>All Product Lines>Support Systems
|
In this Document
Applies to:
Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]
Information in this document applies to any platform.
Symptoms
Customer's system receives FSC3E40 when subsystem is out of conditional capacity. The VSM has reached 100%. The VTDs start receiving intervention required messages and can not mount VTVs
Changes
Cause
The VTSS reached 100%. The box is full of data and can not either recall any VTVs or create new VTVs.
Solution
The customer should monitor their subsystem and work data off as soon as possible.
Commands to keep abreast of when this issue happens:
VT D A DET - Verify the particular VSM has Active migrates
VT D Q DET - Verify the particular VSM does not have queued processes
VT D VTSS - Display the VSM to verify the DBU percentage
VT D RTD - Review RTDs to verify if there are hardware issues
If this does not bring anything up that is the cause, it may be necessary to pause initiators so jobs do not request those VTDs on the VSM until the DBU has had time to work down.
References
<NOTE:1332413.1> - VSM - FSC3E41 & FSC3E42 Production Partition Conditional Capacity Low Threshold Reached