![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1013826.1 : VSM - Message SLS6675E Configuration Error RC=00000004 after Changing VTD Device Addresses
PreviouslyPublishedAs 219772 Applies to:Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]All Platforms SymptomsErrors received during VTCS initialization ChangesVTD device addresses were changed in the VTCS CONFIG for an existing VTSS. CauseThe VTD addresses were not changed in the HCD / IODEF to reflect the change. SolutionUpdate the HCD / IODEF with the correct VTD device addresses. Attachments This solution has no attachment |
||||||||||||
|