![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1014359.1 : VSM - Message SLS6675E Configuration Error RC=00000004 - VTSS Name On Box Does Not Match CONFIG
PreviouslyPublishedAs 221057 Applies to:Sun StorageTek VSM System - Version 4 to 5C [Release 4.0 to 5.0]StorageTek Virtual Storage Manager System 6 (VSM6) - Version All Versions and later Sun StorageTek Enterprise Library Software (ELS) - Version 7.0 and later IBM z/OS on System z SymptomsVTSS reporting errors CauseThe subsystem name between the VTSS box and the VTCS Config do not match. The subsystem name in the box is incorrect. This could occur at a DR site where the same hardware is used by different customers using different naming techniques. This could also occur if a customer is changing the name of their existing production VTSS box or installing a new box that had previously been at a different site. SolutionContact Oracle and have an SR created to send the local Field Service Engineer (FSE) on site to verify whether the the name in the VTSS box is incorrect. If it is, the FSE can reset the name. Attachments This solution has no attachment |
||||||||||||
|