2332709.1 |
Sparc Servers : Replacing a Smaller Older Disk with a Newer Larger Capacity Disk |
2018-02-12
|
1906225.1 |
Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers: some insights for checking domain's console connection |
2018-05-09
|
1626702.1 |
Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Customer Actions: FRU Configured out of Solaris |
2014-07-28
|
1626690.1 |
Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Customer Actions: Multiple Domains Down |
2014-08-04
|
1626689.1 |
Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Customer Actions: Domain Down |
2018-05-08
|
1626688.1 |
Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Customer Actions: Platform Down |
2014-08-04
|
1624583.1 |
Reference Index of CVE IDs and XCP versions (Mx000 Servers) |
2017-10-11
|
1616314.1 |
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 - XSCF Patrol Diagnosis behaviour |
2017-10-11
|
1576115.1 |
How to investigate the Auto Service Request "ASR: Loss of input power" on External I/O Expansion Unit |
2016-07-01
|
1542111.1 |
SPARC Enterprise(R) M3000/M4000/M5000/M8000/M9000 Servers: ASR: SCF-8005-PX - XSCF has Detect a Solaris Domain has Panic'ed |
2017-04-27
|
1533747.1 |
M4000/M5000 Reference for Improving Remote Diagnosibility |
2014-06-26
|
1506017.1 |
SPARC Enterprise(R) M3000/M4000/M5000/M8000/M9000 Servers: SCF-8008-3U - Domain Reset Verification. |
2018-03-01
|
1456060.1 |
Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000: Solaris Hotplug Framework - S10U9 or 142909-17 |
2017-10-11
|
1399469.1 |
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: PCI Card Identification List |
2018-05-10
|
1380260.1 |
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 - XCP Firmware to Defect Cross Reference |
2018-01-09
|
1368688.1 |
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Archived Issues Page |
2014-01-09
|
1221043.1 |
SCF-8002-LX - I2C access failure to an I2C device. |
2017-11-29
|
1174849.1 |
SCF-8000-AE - ESM has exceeded its lifespan |
2017-11-29
|
1021936.1 |
SCF-8005-T5 - TTY buffer for a domain overflowed. |
2014-06-30
|
1021934.1 |
SCF-8005-RA - The XSCF could not determine whether POST is running correctly on a domain/XSB. |
2018-04-04
|
1021932.1 |
SCF-8005-Q2 - The XSB could not be successfully configured into a domain. |
2014-06-25
|
1021931.1 |
SCF-8005-PX - The XSCF has detected that a Solaris domain has panic'ed. |
2017-11-29
|
1021929.1 |
SCF-8005-NE - XSCF firmware is defective. |
2017-11-29
|
1021927.1 |
SCF-8008-3U - Hard-to-diagnose problem detected by OpenBoot PROM. |
2017-11-29
|
1021926.1 |
SCF-8005-LC - Correctable errors within a SC chip have exceeded an acceptable threshold. |
2016-05-25
|
1021919.1 |
SCF-8005-ED - Correctable errors on the interface between a CPU chip and a SC chip have exceeded an acceptable threshold. |
2017-05-09
|
1021914.1 |
SCF-8005-CA - Fatal error detected within a SC chip. |
2014-07-07
|
1021885.1 |
SCF-8004-MP - PSU detected a loss of AC power. |
2014-06-30
|
1021876.1 |
SCF-8006-YS - Hard-to-diagnose failure of the XSCF has occurred. |
2017-11-29
|
1021874.1 |
SCF-8004-G4 - A component in a FRU signaled it has failed. |
2017-11-29
|
1021871.1 |
SCF-8006-WP - Hardware problem detected within an XSCFU. |
2017-11-29
|
1021868.1 |
SCF-8004-DQ - An undervoltage or overvoltage warning from a device or FRU. |
2016-10-27
|
1021851.1 |
SCF-8004-45 - SC chip detected a power failure. |
2013-01-23
|
1021847.1 |
SCF-8003-S4 - Error detected within a MBC chip during self-test. |
2015-06-01
|
1021837.1 |
SCF-8006-3J - Over-temperature warning condition detected on platform. |
2017-08-03
|
1021834.1 |
SCF-8003-K5 - Non-fatal uncorrectable error occurred on the interface between a MBC chip and the XSCF. |
2017-12-21
|
1021833.1 |
SCF-8006-1X - Under-temperature condition detected by the inlet temperature sensor. |
2014-06-30
|
1021830.1 |
SCF-8005-YH - Fan rotation speed lower than its predefined threshold or fan stopped completely. |
2018-01-18
|
1021823.1 |
SCF-8003-0S - Correctable errors within the part of a MAC chip that controls a memory bank have exceeded an acceptable threshold. |
2014-05-19
|
1021517.1 |
SCF-8002-XS - Non-fatal uncorrectable error was detected within the part of a MAC chip that controls a memory bank. |
2014-05-19
|
1021515.1 |
SCF-8002-VP - Fatal error was detected within the part of a MAC chip that controls a memory bank. |
2014-06-12
|
1021503.1 |
SCF-8002-FA - Failure to boot Solaris on a domain using a device behind a PCI-Express/PCI-X bridge. |
2014-02-04
|
1021502.1 |
SCF-8002-ES - Failure to boot Solaris on a domain using a device in a PCI-Express slot. |
2014-06-30
|
1021500.1 |
SCF-8002-D5 - Failure to boot Solaris on a domain using a device in a PCI-X slot. |
2014-02-04
|
1021499.1 |
SCF-8002-CY - Failure to boot Solaris on a domain via GbE. |
2014-01-30
|
1021491.1 |
SCF-8002-3E - Non-fatal uncorrectable error occurred due to a PCI-X card in a PCI slot. |
2014-11-26
|
1021490.1 |
SCF-8002-2J - Non-fatal uncorrectable error occurred due to a PCI-Express card in a PCI-Express slot. |
2014-01-30
|
1021455.1 |
SCF-8001-VY - fatal error was detected within a Gigabit Ethernet (GbE) controller. |
2014-06-25
|
1021423.1 |
SCF-8001-SA - Fatal error was detected on a PCI-X card in a PCI slot. |
2014-06-30
|
1021422.1 |
SCF-8001-RP - Fatal error detected on a PCI-Express card in a PCI slot. |
2014-02-04
|
1021419.1 |
SCF-8001-P2 - Fatal error detected within an IOC chip. |
2012-10-08
|
1021415.1 |
SCF-8001-KC - Failure to boot Solaris on a domain via an internal disk drive on the SAS controller. |
2017-01-25
|
1021330.1 |
SCF-8001-4X - Number of uncorrectable and correctable errors on single DIMM exceeds an acceptable threshold. |
2017-11-17
|
1021329.1 |
SCF-8001-34 - Number of permanent correctable errors (PCE's) on single DIMM exceeds an acceptable threshold. |
2017-11-29
|
1021328.1 |
SCF-8001-2R - Permanent correctable memory error (PCE) has been detected. |
2014-09-08
|
1021326.1 |
SCF-8001-0Q - Uncorrectable memory error (UE) has been detected. |
2017-11-29
|
1021325.1 |
SCF-8000-YC - A fatal error in a DIMM detected by POST |
2014-09-08
|
1021220.1 |
PCI-8000-ED - PCI subsystem problem |
2017-09-19
|
1021179.1 |
SCF-8000-CJ - Internal fatal error within a CPU chip was detected. |
2015-03-17
|