Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1368688.1
Update Date:2014-01-09
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1368688.1 :   Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Archived Issues Page  


Related Items
  • Sun SPARC Enterprise M9000-64 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M8000 Server
  •  
  • Sun SPARC Enterprise M3000 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Mx000
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>OPL Servers
  •  




In this Document
Purpose
Details
 Hardware
 XCP Issue
 IO Issue
 DR Issue
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Internal Only Information

Applies to:

Sun SPARC Enterprise M9000-32 Server - Version Not Applicable and later
Sun SPARC Enterprise M3000 Server - Version Not Applicable and later
Sun SPARC Enterprise M5000 Server - Version Not Applicable and later
Sun SPARC Enterprise M8000 Server - Version Not Applicable and later
Sun SPARC Enterprise M9000-64 Server - Version Not Applicable and later
Information in this document applies to any platform.

Purpose

This document provides a listing of archived issue known to affect the OPL platform.
Current and Active issues are at 1315765.1
Also check the XCP release notes for known issues.

Details

Sparc Home Product Issues   Patches/Firmware   Training/Knowledge    I/O Expansion
Documentation  M3000 M4000 M5000 M8000 M9000
SSH M3000
M4000 M5000 M8000 M9000

 

Hardware

IssueStatusDocumentsCR/SRResolution Updated
Power Cord Retaining Clip on M4000 and M5000 Loose Resolved 1019255.1   Work Around: Tie Wrap or Velcro the Clip in place so the cord will not pull out.
Good Clip  Bad Clip Workaround Clip
05/21/2008
M8000 and M9000 PSUBP connector shoulder screws should be inspected upon PSU failure Resolved 1018989.1 <BUG 15414000> See FAB 1018989.1 02/12/2008
Customers complain about fans being too noisy in M4000 / M5000 systems. Resolved     See document 1339901.1 for Noisy Fan Troubleshooting information. 01/05/2009
Dual Redundancy Power ( DPF ) wired incorrectly. Resolved     DPF fix documentation
OPS augmented processes to test both grids
01/05/2009
M4000 Input Wiring is incorrect Resolved in the factory by additional testing. Collaborate if found on a new system.     M4000 Input Wiring Fix 02/03/2009
M8000 and M9000 fan trays come loose and down platform Resolved 1019704.1 <BUG 15488439> XCP includes software fix which mitigates the loss of a fan tray. Sun Alert internal section is revised with available field retaining arm retrofit kit. 09/17/2009
M5000 - MBC failures SCF-8003-LS and/or SCF-8003-HA
Specifically looking for cases that have a fatal error immediately before the serious error.
Deferred     Still under investigation by engineering.  Current action is to replace the faulted MBU.

10-Oct-2011

Archived 09-Jan2014

 


XCP Issue

IssueStatusDocumentsCR/SRResolutionUpdated
showstatus indicates no failure, but Check LED(on OPNL) is turned on. Fixed in XCP1070   <BUG 15449915>    -
Front panel LED still shows amber light after clear all faulty components. Closed as dupe of 6645828 "Could not write FRU-ID status" is detected   <BUG 15451103>    -
"Could not write FRU-ID status" is detected Fixed in xcp 1071 None <BUG 15447970>   04/20/2008
           

 


IO Issue

IssueStatusDocumentsCR/SRResolutionUpdated
IOU SAS WWID becoming unprogrammed Closed / Will not fix                 <BUG 15478532>

Workaround - Powercycle the affected IOU twice.

06/03/08

 


DR Issue

IssueStatusDocumentsCR/SRResolutionUpdated
Deleteboard / moveboard - delete_memory thread is hanging on kphysm_del_cleanup during dr testing. Fix Delivered - Fixed in S10_u6 / snv_87 1019090.1      <BUG 15429433> The DR deleteboard or moveboard operations might hang if either of the following condition exists:
- A DIMM on the target board has disabled memory and the board being
DR'ed has permanent memory assigned to it.
- The system board that is being deleted via DR has
permanent memory and the memory are being migrated
to a system board with smaller amount of memory installed.
Workaround: Don't use DR in the above situation.
02/25/2008

References

<BUG:15414000> - SUNBT6588111 OPL DC: SCREWS BREAKING ON ACSBP ASSEMBLY
<BUG:15447970> - SUNBT6645828 "COULD NOT WRITE FRU-ID STATUS" IS DETECTED
<BUG:15449915> - SUNBT6649341 SHOWSTATUS INDICATES NO FAILURE, BUT CHECK LED(ON OPNL) IS LIT
<BUG:15451103> - SUNBT6651370 FRONT PANEL LED STILL SHOWS AMBER LIGHT AFTER CLEAR ALL FAULTY COMP
<BUG:15478532> - SUNBT6698399 IOU SAS WWID BECOMING UNPROGRAMMED
<BUG:15488439> - SUNBT6716245-XCP107A XSCF SHOULD SHUTDOWN PLATFORM BY EXCEEDED TEMPERATURES RATH
<NOTE:1002631.1> - Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000 XSCF Control Package (XCP) Firmware Image Software Version Matrix Information
<BUG:15429433> - SUNBT6614737-SOLARIS_11 DELETE_MEMORY THREAD IS HANGING ON KPHYSM_DEL_CLEANUP DU
<NOTE:1018989.1> - M8000 and M9000 PSUBP connector shoulder screws should be inspected upon PSU failure.
<NOTE:1019090.1> - Solaris 10 Under Certain Conditions, Dynamic Reconfiguration (DR) "deleteboard" and "moveboard" Operations May Hang on a SPARC Enterprise M4000/M5000/M8000/M9000
<NOTE:1019255.1> - Sun SPARC Enterprise M4000/M5000 Power Cord Clips not fully engaging
<NOTE:1019704.1> - Sun SPARC Enterprise M8000 and M9000 Servers With Certain Firmware May Experience Unexpected Platform Outage
<NOTE:1315765.1> - Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Current Issues Page
<NOTE:1339901.1> - Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000: Troubleshooting a Noisy FAN on OPL Servers