Asset ID: |
1-79-1021823.1 |
Update Date: | 2014-05-19 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1021823.1
:
SCF-8003-0S - Correctable errors within the part of a MAC chip that controls a memory bank have exceeded an acceptable threshold.
Related Items |
- Sun SPARC Enterprise M4000 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
SCF-8003-0S
Applies to:
Sun Microsystems > Servers
Sun SPARC Enterprise M4000 Server
All Platforms
Purpose
Provide additional information for message ID: SCF-8003-0S
Details
Predictive Self-Healing Article
Correctable errors within the part of a MAC chip that controls a memory bank have exceeded an acceptable threshold.
Type
- Fault
- fault.chassis.SPARC-Enterprise.asic.mac.bank.ce
Severity
- Major
Description
- The number of correctable errors detected within the part of a MAC chip that controls a memory bank has exceeded an acceptable threshold.
Automated Response
- Memory associated with the memory bank will be deconfigured after the platform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.
Impact
- No immediate impact. Memory associated with the memory bank will be deconfigured after the platform is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.
Suggested Action for System Administrator
- Schedule a repair action to replace the affected Field Replaceable Unit (FRU), the identity of which can be determined using fmdump -v -u EVENT_ID. Please consult the detail section of the knowledge article for additional information.
Details
- The number of correctable errors detected within the part of a MAC chip
that controls a memory bank has exceeded an acceptable threshold.
SPARC Enterprise M3000 platform:
There is no MAC chip on a M3000 platform.
The JSC chip provides the same functionality as the MAC chip and is located on the MBU.
Domain using the memory bank will be reset.
Memory associated with the memory bank will be deconfigured after the platform is power cycled
or after the domain reboots or after a Dynamic Reconfiguration operation is performed.
SPARC Enterprise M4000/M5000 platforms:
The MAC Chip is located on the Memory board.
Domain using the memory bank will be reset.
Memory associated with the memory bank will be deconfigured after the platform is power cycled
or after the domain reboots or after a Dynamic Reconfiguration operation is performed.
SPARC Enterprise M8000/M9000 platforms:
The MAC Chip us located on the CMU.
Domain using the memory bank will be reset.
Memory associated with the memory bank will be deconfigured after the platform is power cycled
or after the domain reboots or after a Dynamic Reconfiguration operation is performed.
The recommended service action for this event is to schedule the replacement of the affected FRU.
LEGEND
RED = SUNW-MSG-ID
BLUE = EVENT_ID
GREEN = FRU
Step 1. Collect the fault message (use one of the following methods):
Single-line fault message displayed on the XSCF console:
Mar 20 21:19:15 san-ff2-21-0 fmd: SOURCE: sde, REV: 1.12, CSN: 7860000772
EVENT-ID: 0b0ac2ad-6d03-4b8d-b05a-d80d8f3841b9
Refer to http://www.sun.com/msg/ SCF-8003-0S for detailed information.
Complete fault message using 'fmdump -m' on the XSCF console:
MSG-ID: SCF-8003-0S, TYPE: Fault, VER: 1, SEVERITY: Major
EVENT-TIME: Tue Mar 20 21:19:15 UTC 2007
PLATFORM: SPARC-Enterprise, CSN: 7860000772, HOSTNAME: san-ff2-21-0
SOURCE: sde, REV: 1.12
EVENT-ID: 0b0ac2ad-6d03-4b8d-b05a-d80d8f3841b9
DESC: The number of correctable errors detected within the part of a MAC chip that controls a memory
bank has exceeded an acceptable threshold.
Refer to http://www.sun.com/msg/SCF-8003-0S for more information.
AUTO-RESPONSE: Memory associated with the memory bank will be deconfigured after the platform is power cycled or after
the domain reboots or after a Dynamic Reconfiguration operation is performed.
IMPACT: No immediate impact. Memory associated with the memory bank will be deconfigured after the platform
is power cycled or after the domain reboots or after a Dynamic Reconfiguration operation is performed.
REC-ACTION: Schedule a repair action to replace the affected Field Replaceable Unit (FRU),
the identity of which can be determined using fmdump -v -u EVENT_ID.
Please consult the detail section of the knowledge article for additional information.
Step 2. Collect the output from the 'fmdump -v -u EVENT_ID' command
SPARC Enterprise platform example:
xscf> fmdump -v -u 0b0ac2ad-6d03-4b8d-b05a-d80d8f3841b9
TIME UUID MSG-ID
Mar 20 21:19:15.4243 0b0ac2ad-6d03-4b8d-b05a-d80d8f3841b9 SCF-8003-0S
100% fault.chassis.SPARC-Enterprise.asic.mac.bank.ce
Problem in: hc:///chassis=0/cmu=0/mac=0/bank=0
Affects: hc:///chassis=0/cmu=0/mac=0/bank=0
FRU: hc://:product-id=SPARC-Enterprise:chassis-id=7860000772:
server-id=san-ff2-21-0:
part=CA20393-B54X 001AA:revision=0101/component=/MBU_B/MEMB#0
Step 3. Contact your Authorized Service Provider.
If you require additional information, please refer to Document 1002526.1.
Product
Other Server Models 1000-9999
Product_uuid
41751310-63d5-11d7-9179-89d0596b661d
Attachments
This solution has no attachment