Solution Type  Predictive Self-Healing Sure

Solution  1021936.1 :   SCF-8005-T5 - TTY buffer for a domain overflowed.  


Related Items
  • Sun SPARC Enterprise M8000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
  • Sun SPARC Enterprise M3000 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M9000-64 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  

PreviouslyPublishedAs
SCF-8005-T5


Applies to:

Sun SPARC Enterprise M3000 Server - Version All Versions and later
Sun SPARC Enterprise M4000 Server - Version All Versions and later
Sun SPARC Enterprise M5000 Server - Version All Versions and later
Sun SPARC Enterprise M8000 Server - Version All Versions and later
Sun SPARC Enterprise M9000-32 Server - Version All Versions and later
All Platforms

Purpose

Provide additional information for message ID: SCF-8005-T5

Details

Predictive Self-Healing Article
TTY buffer for a domain overflowed.

Type

Upset
  upset.chassis.domain.tty-overflow

Severity

Minor

Description

TTY buffer for a domain overflowed, resulting in lost domain console data.

Automated Response

No action is taken as a result of this fault.

Impact

Domain console data is lost.

Suggested Action for System Administrator

None. Please consult the detail section of the knowledge article for additional information.

Details

TTY buffer for a domain overflowed, resulting in lost domain console data.

Domain console data is lost.

No action is taken as a result of this fault and no service action is required.

This could be the result of problems with a telnet client.


   If the problem persists, proceed with the steps outlined below.


Step 1. Collect the fault message:


   Single-line fault message displayed on the XSCF console:

   Mar 20 21:41:49 san-ff2-21-0 fmd: SOURCE: sde, REV: 1.12, CSN: 7860000772  
   EVENT-ID: 2d8c40d6-4810-4e9c-99c9-1a7eadbc54ee
   Refer to http://www.sun.com/msg/SCF-8005-T5 for detailed information.


Step 2. Collect the output from the 'fmdump -v -u EVENT_ID' command

   
   SPARC Enterprise platform example:
 
   xscf> fmdump -v -u 2d8c40d6-4810-4e9c-99c9-1a7eadbc54ee

         TIME                 UUID                                 MSG-ID
         Mar 20 21:41:49.1759 2d8c40d6-4810-4e9c-99c9-1a7eadbc54ee SCF-8005-T5
           100%  upset.chassis.domain.tty-overflow

                 Problem in: hc:///chassis=0/domain=0
                    Affects: -
                        FRU: hc://:product-id=SPARC-Enterprise:chassis-id=7860000772:
                             server-id=san-ff2-21-0/component=CHASSIS


Step 3. Collect a snapshot from the xscfu and contact your Authorized Service Provider.