Asset ID: |
1-79-1021936.1 |
Update Date: | 2014-06-30 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1021936.1
:
SCF-8005-T5 - TTY buffer for a domain overflowed.
Related Items |
- Sun SPARC Enterprise M8000 Server
- Sun SPARC Enterprise M4000 Server
- Sun SPARC Enterprise M3000 Server
- Sun SPARC Enterprise M9000-32 Server
- Sun SPARC Enterprise M5000 Server
- Sun SPARC Enterprise M9000-64 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
SCF-8005-T5
Applies to:
Sun SPARC Enterprise M3000 Server - Version All Versions and later
Sun SPARC Enterprise M4000 Server - Version All Versions and later
Sun SPARC Enterprise M5000 Server - Version All Versions and later
Sun SPARC Enterprise M8000 Server - Version All Versions and later
Sun SPARC Enterprise M9000-32 Server - Version All Versions and later
All Platforms
Purpose
Provide additional information for message ID: SCF-8005-T5
Details
Predictive Self-Healing Article
TTY buffer for a domain overflowed.
Type
- Upset
- upset.chassis.domain.tty-overflow
Severity
- Minor
Description
- TTY buffer for a domain overflowed, resulting in lost domain console data.
Automated Response
- No action is taken as a result of this fault.
Impact
- Domain console data is lost.
Suggested Action for System Administrator
- None. Please consult the detail section of the knowledge article for additional information.
Details
- TTY buffer for a domain overflowed, resulting in lost domain console data.
Domain console data is lost.
No action is taken as a result of this fault and no service action is required.
This could be the result of problems with a telnet client.
If the problem persists, proceed with the steps outlined below.
Step 1. Collect the fault message:
Single-line fault message displayed on the XSCF console:
Mar 20 21:41:49 san-ff2-21-0 fmd: SOURCE: sde, REV: 1.12, CSN: 7860000772
EVENT-ID: 2d8c40d6-4810-4e9c-99c9-1a7eadbc54ee
Refer to http://www.sun.com/msg/SCF-8005-T5 for detailed information.
Step 2. Collect the output from the 'fmdump -v -u EVENT_ID' command
SPARC Enterprise platform example:
xscf> fmdump -v -u 2d8c40d6-4810-4e9c-99c9-1a7eadbc54ee
TIME UUID MSG-ID
Mar 20 21:41:49.1759 2d8c40d6-4810-4e9c-99c9-1a7eadbc54ee SCF-8005-T5
100% upset.chassis.domain.tty-overflow
Problem in: hc:///chassis=0/domain=0
Affects: -
FRU: hc://:product-id=SPARC-Enterprise:chassis-id=7860000772:
server-id=san-ff2-21-0/component=CHASSIS
Step 3. Collect a snapshot from the xscfu and contact your Authorized Service Provider.
Attachments
This solution has no attachment