Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1021868.1
Update Date:2016-10-27
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1021868.1 :   SCF-8004-DQ - An undervoltage or overvoltage warning from a device or FRU.  


Related Items
  • Sun SPARC Enterprise M8000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
  • Sun SPARC Enterprise M3000 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M9000-64 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  

PreviouslyPublishedAs
SCF-8004-DQ


Applies to:

Sun SPARC Enterprise M3000 Server - Version All Versions and later
Sun SPARC Enterprise M4000 Server - Version All Versions and later
Sun SPARC Enterprise M5000 Server - Version All Versions and later
Sun SPARC Enterprise M8000 Server - Version All Versions and later
Sun SPARC Enterprise M9000-32 Server - Version All Versions and later
All Platforms

Purpose

Provide additional information for message ID: SCF-8004-DQ
 

Scope

 

Details

Predictive Self-Healing Article
An undervoltage or overvoltage warning from a device or FRU.

Type

Fault
  fault.chassis.power.warning

Severity

Minor

Description

An undervoltage or overvoltage warning was detected by a device or FRU.

Automated Response

Nothing is deconfigured and no action is taken as a result of this warning.

Impact

None.

Suggested Action for System Administrator

Schedule a repair action to replace the affected Field Replaceable Unit (FRU), the identity of which can be determined using fmdump -v -u EVENT_ID. Please consult the detail section of the knowledge article for additional information.

Details

An undervoltage or overvoltage warning was detected by a device or FRU.
 
The FRU or device with the undervoltage or overvoltage warning
can be identified from the FMRI of the fault report.

The following section provides a list of the potential FRUs and devices that can
detect an undervoltage or overvoltage warning, and specifies the impact and automated
actions taken by the platform or domain in response to the fault.


  SPARC Enterprise M3000 platform:


      Fan Backplane (FANBP_B):
      Motherboard Unit (MBU):

         No immediate action is taken because of this fault.
         Nothing is deconfigured.



   SPARC Enterprise M4000/M5000 platforms:


      Fan Backplane (FANBP_B):
      Fan Backplane (FANBP_C):
      DDC_A on a Motherboard:
      DDC_A on an IOU:
      DDC_B on a Motherboard:
      DDC_B on a DDC Riser:
      DDC Riser (DDCR) on an IO Unit (IOU):
      IO Unit (IOU):
      Memory Board (MEMB):
      CPU Module (CPUM):
      CPU/Memory Unit (CMU):
      Crossbar Unit (XBU):

         No immediate action is taken because of this fault.
         Nothing is deconfigured.



   SPARC Enterprise M8000/M9000 platforms:


      DDC_A on a Backplane (BP_A):
      IO Unit (IOU):
      CPU Module (CPUM):
      CPU/Memory Unit (CMU):
      Crossbar Unit (XBU):
      Backplane (BP_A):
      Switch Backplane (SWBP):
      Media Backplane (MEDBP):
      DVD Unit (DVDU):
      Tape Unit (TAPEU):

         No immediate action is taken because of this fault.
         Nothing is deconfigured.

 
      Clock Unit (CLKU):

         No immediate action is taken because of this fault.
         
         If the Clock Unit is the active Clock Unit,
         then the administrator should use the "clockboard" command
         to switch to the standby clockboard at the next platform powerup.




The recommended service action for this event is to schedule the replacement of the affected FRU.


Step 1. Collect the Fault Message  (two methods)


   Single-line fault message displayed on the XSCF console:

   Mar 27 15:15:58 nwk-dc2-1-sc0 fmd: SOURCE: sde, REV: 1.12, CSN: nwk-dc2-1  
   EVENT-ID: e76aee42-721c-4800-a1c1-b09410e56ac4
   Refer to http://www.sun.com/msg/SCF-8004-DQ for detailed information.



   Complete fault message using 'fmdump -m' on the XSCF console:

   MSG-ID: SCF-8004-DQ, TYPE: Fault, VER: 1, SEVERITY: Minor
   EVENT-TIME: Tue Mar 27 15:15:58 PDT 2007
   PLATFORM: SPARC-Enterprise, CSN: nwk-dc2-1, HOSTNAME: nwk-dc2-1-sc0
   SOURCE: sde, REV: 1.12
   EVENT-ID: e76aee42-721c-4800-a1c1-b09410e56ac4
   DESC: An undervoltage or overvoltage warning was detected by a device or FRU.
   Refer to http://www.sun.com/msg/SCF-8004-DQ for more information.
   AUTO-RESPONSE: Nothing is deconfigured and no action is taken as a result of this warning.
   IMPACT: None.
   REC-ACTION: Schedule a repair action to replace the affected Field Replaceable Unit (FRU),
   the identity of which can be determined using fmdump -v -u EVENT_ID.
   Please consult the detail section of the knowledge article for additional information.


Step 2. Collect the output from the 'fmdump  -v  -u  ' command
 


   SPARC Enterprise platform example:

   xscf> fmdump -v -u e76aee42-721c-4800-a1c1-b09410e56ac4

         TIME                 UUID                                 MSG-ID
         Mar 27 15:15:58.4661 e76aee42-721c-4800-a1c1-b09410e56ac4 SCF-8004-DQ
  100%  fault.chassis.power.warning

        Problem in: hc:///chassis=0/cmu=0/cpum=0
           Affects: hc:///chassis=0/cmu=0/cpum=0
               FRU: hc://:product-id=SPARC-Enterprise:chassis-id=nwk-dc2-1:
                    server-id=nwk-dc2-1-sc0:serial=PP0640S689:
                    part=CA06620-D021 A6:revision=0201/component=/CMU#0/CPUM#0


Step 3. Collect a snapshot from the XSCFU.  See doc 2097446.1 for instructions on gathering snapshot.
Step 4. Contact your Authorized Service Provider.



If you require additional information, please refer to Document 1002526.1.

References

<NOTE:2097446.1> - SRDC – SPARC Mx000 and M10-x systems: Simple Instructions to Collect an XCP Snapshot

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback