Asset ID: |
1-79-1021329.1 |
Update Date: | 2017-11-29 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1021329.1
:
SCF-8001-34 - Number of permanent correctable errors (PCE's) on single DIMM exceeds an acceptable threshold.
Related Items |
- Sun SPARC Enterprise M8000 Server
- Sun SPARC Enterprise M4000 Server
- Sun SPARC Enterprise M3000 Server
- Sun SPARC Enterprise M9000-32 Server
- Sun SPARC Enterprise M5000 Server
- Sun SPARC Enterprise M9000-64 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
SCF-8001-34
Applies to:
Sun SPARC Enterprise M4000 Server - Version All Versions and later
Sun SPARC Enterprise M3000 Server - Version All Versions and later
Sun SPARC Enterprise M5000 Server - Version All Versions and later
Sun SPARC Enterprise M8000 Server - Version All Versions and later
Sun SPARC Enterprise M9000-32 Server - Version All Versions and later
All Platforms
Purpose
Provide additional information for message ID: SCF-8001-34
Scope
Details
Predictive Self-Healing Article
Number of permanent correctable errors (PCE's) on single DIMM exceeds an acceptable threshold.
Type
- Fault
- fault.chassis.SPARC-Enterprise.memory.dimm.pce
Severity
- Minor
Description
- The number of permanent correctable errors (PCE's) on single DIMM exceeds an acceptable threshold.
Automated Response
- No immediate action is taken and nothing is deconfigured.
Impact
- Minimal impact to system.
Suggested Action for System Administrator
- Schedule a repair action to replace the affected Field Replaceable Unit (FRU), the identity of which can be determined using fmdump -v -u EVENT_ID. Please consult the detail section of the knowledge article for additional information.
Details
- The number of permanent correctable errors (PCE's) on a single DIMM exceeds an acceptable threshold.
No immediate action is taken and nothing is deconfigured.
The recommended service action for this event is to schedule the replacement of the affected FRU.
Step 1. Collect the fault message (use one of the following methods):
Single-line fault message displayed on the XSCF console:
Mar 20 21:23:50 san-ff2-21-0 fmd: SOURCE: sde, REV: 1.12, CSN: 7860000772
EVENT-ID: eaee181f-9de1-4105-a7c0-635b52381bad
Refer to http://www.sun.com/msg/ SCF-8001-34 for detailed information.
Complete fault message using 'fmdump -m' on the XSCF console:
MSG-ID: SCF-8001-34, TYPE: Fault, VER: 1, SEVERITY: Minor
EVENT-TIME: Tue Mar 20 21:23:50 UTC 2007
PLATFORM: SPARC-Enterprise, CSN: 7860000772, HOSTNAME: san-ff2-21-0
SOURCE: sde, REV: 1.12
EVENT-ID: eaee181f-9de1-4105-a7c0-635b52381bad
DESC: The number of permanent correctable errors (PCE's) on single DIMM exceeds an
acceptable threshold.
Refer to http://www.sun.com/msg/SCF-8001-34 for more information.
AUTO-RESPONSE: No immediate action is taken and nothing is deconfigured.
IMPACT: Minimal impact to system.
REC-ACTION: Schedule a repair action to replace the affected Field Replaceable Unit (FRU),
the identity of which can be determined using fmdump -v -u EVENT_ID.
Please consult the detail section of the knowledge article for additional information.
Step 2. Collect the output from the 'fmdump -v -u EVENT_ID' command
SPARC Enterprise platform example:
xscf> fmdump -v -u eaee181f-9de1-4105-a7c0-635b52381bad
TIME UUID MSG-ID
Mar 20 21:23:50.1300 eaee181f-9de1-4105-a7c0-635b52381bad SCF-8001-34
100% fault.chassis.SPARC-Enterprise.memory.dimm.pce
Problem in: hc:///chassis=0/cmu=0/mem=0
Affects: hc:///chassis=0/cmu=0/mem=0
FRU: hc://:product-id=SPARC-Enterprise:chassis-id=7860000772:
server-id=san-ff2-21-0:serial=04126711:
part=72T128000HR3.7A:revision=252b/component=/MBU_B/MEMB#0/MEM#3A
Step 3. Contact your Authorized Service Provider.
If you require additional information, please refer to Document 1002526.1.
Attachments
This solution has no attachment