Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1021329.1
Update Date:2017-11-29
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1021329.1 :   SCF-8001-34 - Number of permanent correctable errors (PCE's) on single DIMM exceeds an acceptable threshold.  


Related Items
  • Sun SPARC Enterprise M8000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
  • Sun SPARC Enterprise M3000 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M9000-64 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  

PreviouslyPublishedAs
SCF-8001-34


Applies to:

Sun SPARC Enterprise M4000 Server - Version All Versions and later
Sun SPARC Enterprise M3000 Server - Version All Versions and later
Sun SPARC Enterprise M5000 Server - Version All Versions and later
Sun SPARC Enterprise M8000 Server - Version All Versions and later
Sun SPARC Enterprise M9000-32 Server - Version All Versions and later
All Platforms

Purpose

Provide additional information for message ID: SCF-8001-34

Scope

 

Details

Predictive Self-Healing Article
Number of permanent correctable errors (PCE's) on single DIMM exceeds an acceptable threshold.

Type

Fault
  fault.chassis.SPARC-Enterprise.memory.dimm.pce

Severity

Minor

Description

The number of permanent correctable errors (PCE's) on single DIMM exceeds an acceptable threshold.

Automated Response

No immediate action is taken and nothing is deconfigured.

Impact

Minimal impact to system.

Suggested Action for System Administrator

Schedule a repair action to replace the affected Field Replaceable Unit (FRU), the identity of which can be determined using fmdump -v -u EVENT_ID. Please consult the detail section of the knowledge article for additional information.

Details

The number of permanent correctable errors (PCE's) on a single DIMM exceeds an acceptable threshold.

No immediate action is taken and nothing is deconfigured.


The recommended service action for this event is to schedule the replacement of the affected FRU.


Step 1. Collect the fault message (use one of the following methods):


   Single-line fault message displayed on the XSCF console:

   Mar 20 21:23:50 san-ff2-21-0 fmd: SOURCE: sde, REV: 1.12, CSN: 7860000772  
   EVENT-ID: eaee181f-9de1-4105-a7c0-635b52381bad
   Refer to http://www.sun.com/msg/ SCF-8001-34 for detailed information.


   Complete fault message using 'fmdump -m' on the XSCF console:

   MSG-ID:  SCF-8001-34, TYPE: Fault, VER: 1, SEVERITY: Minor
   EVENT-TIME: Tue Mar 20 21:23:50 UTC 2007
   PLATFORM: SPARC-Enterprise, CSN: 7860000772, HOSTNAME: san-ff2-21-0
   SOURCE: sde, REV: 1.12
   EVENT-ID: eaee181f-9de1-4105-a7c0-635b52381bad
   DESC: The number of permanent correctable errors (PCE's) on single DIMM exceeds an
   acceptable threshold.
   Refer to http://www.sun.com/msg/SCF-8001-34 for more information.
   AUTO-RESPONSE: No immediate action is taken and nothing is deconfigured.
   IMPACT: Minimal impact to system.
   REC-ACTION: Schedule a repair action to replace the affected Field Replaceable Unit (FRU),
   the identity of which can be determined using fmdump -v -u EVENT_ID.
   Please consult the detail section of the knowledge article for additional information.


Step 2. Collect the output from the 'fmdump -v -u EVENT_ID' command

   SPARC Enterprise platform example:
 
   xscf> fmdump -v -u eaee181f-9de1-4105-a7c0-635b52381bad

         TIME                 UUID                                 MSG-ID
         Mar 20 21:23:50.1300 eaee181f-9de1-4105-a7c0-635b52381bad SCF-8001-34
           100%  fault.chassis.SPARC-Enterprise.memory.dimm.pce

                 Problem in: hc:///chassis=0/cmu=0/mem=0
                    Affects: hc:///chassis=0/cmu=0/mem=0
                        FRU: hc://:product-id=SPARC-Enterprise:chassis-id=7860000772:
                             server-id=san-ff2-21-0:serial=04126711:
                             part=72T128000HR3.7A:revision=252b/component=/MBU_B/MEMB#0/MEM#3A


Step 3. Contact your Authorized Service Provider.

If you require additional information, please refer to Document 1002526.1.

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback