Asset ID: |
1-79-1021415.1 |
Update Date: | 2017-01-25 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1021415.1
:
SCF-8001-KC - Failure to boot Solaris on a domain via an internal disk drive on the SAS controller.
Related Items |
- Sun SPARC Enterprise M8000 Server
- Sun SPARC Enterprise M4000 Server
- Sun SPARC Enterprise M3000 Server
- Sun SPARC Enterprise M9000-32 Server
- Sun SPARC Enterprise M5000 Server
- Sun SPARC Enterprise M9000-64 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
SCF-8001-KC
Applies to:
Sun SPARC Enterprise M4000 Server - Version All Versions and later
Sun SPARC Enterprise M5000 Server - Version All Versions and later
Sun SPARC Enterprise M8000 Server - Version All Versions and later
Sun SPARC Enterprise M9000-32 Server - Version All Versions and later
Sun SPARC Enterprise M9000-64 Server - Version All Versions and later
All Platforms
Purpose
Provide additional information for message ID: SCF-8001-KC
Scope
Details
Predictive Self-Healing Article
Failure to boot Solaris on a domain via an internal disk drive on the SAS controller.
Type
- upset
- upset.chassis.SPARC-Enterprise.io.disk.boot
Severity
- Critical
Description
- Failure to boot Solaris on a domain via an internal disk drive on the SAS controller.
Automated Response
- Nothing is deconfigured.
Impact
- The domain drops to the OpenBoot PROM 'ok' prompt.
Suggested Action for System Administrator
- The platform administrator should investigate the cause of the boot problem and schedule a service action, if necessary. Please consult the detail section of the knowledge article for additional information.
Details
- Failure to boot Solaris on a domain via an internal disk drive on the SAS controller.
This message is informational in nature and not a diagnosis.
The OpenBoot PROM fcode did not detect any fault with the device
and the XSCF software was unable to determine cause.
The domain drops to the OpenBoot PROM 'ok' prompt.
Potential causes may include, but are not limited to the following:
Poor physical connection;
No power to device;
Missing disk label;
Corrupted boot image;
Booting from the wrong partition on the device;
Attempting to boot from the wrong device;
Device path missing;
Path to device is deconfigured;
External or application issues such as volume management;
Difficult to diagnose hardware issues.
If you require further assistance, proceed with the steps below.
Step 1. Collect the fault message (use one of the following methods):
Single-line fault message displayed on the XSCF console:
Mar 20 21:13:06 san-ff2-21-0 fmd: SOURCE: sde, REV: 1.12, CSN: 7860000772
EVENT-ID: a6f09f62-f00a-46b7-8912-39114607792a
Refer to http://www.sun.com/msg/SCF-8001-KC for detailed information.
Complete fault message using 'fmdump -m' on the XSCF console:
MSG-ID: SCF-8001-KC, TYPE: upset, VER: 1, SEVERITY: Critical
EVENT-TIME: Tue Mar 20 21:13:05 UTC 2007
PLATFORM: SPARC-Enterprise, CSN: 7860000772, HOSTNAME: san-ff2-21-0
SOURCE: sde, REV: 1.12
EVENT-ID: a6f09f62-f00a-46b7-8912-39114607792a
DESC: Failure to boot Solaris on a domain via an internal disk drive on the SAS controller.
Refer to http://www.sun.com/msg/SCF-8001-KC for more information.
AUTO-RESPONSE: Nothing is deconfigured.
IMPACT: The domain drops to the OpenBoot PROM 'ok' prompt.
REC-ACTION: The platform administrator should investigate the cause of the boot problem
and schedule a service action, if necessary.
Please consult the detail section of the knowledge article for additional information.
Step 2. Collect the output from the 'fmdump -v -u EVENT_ID' command
SPARC Enterprise platform example:
xscf> fmdump -v -u a6f09f62-f00a-46b7-8912-39114607792a
TIME UUID MSG-ID
Mar 20 21:13:05.9610 a6f09f62-f00a-46b7-8912-39114607792a SCF-8001-KC
100% upset.chassis.SPARC-Enterprise.io.disk.boot
Problem in: hc:///chassis=0/iou=0/ioc=0/ch=0/leaf=0/pci_br=0/sas=0/disk=0
Affects: -
FRU: hc://:product-id=SPARC-Enterprise:chassis-id=7860000772:
server-id=san-ff2-21-0/component=/HDD#0
Step 3. Contact your Authorized Service Provider.
Attachments
This solution has no attachment