Asset ID: |
1-79-1021422.1 |
Update Date: | 2014-02-04 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1021422.1
:
SCF-8001-RP - Fatal error detected on a PCI-Express card in a PCI slot.
Related Items |
- Sun SPARC Enterprise M8000 Server
- Sun SPARC Enterprise M4000 Server
- Sun SPARC Enterprise M3000 Server
- Sun SPARC Enterprise M9000-32 Server
- Sun SPARC Enterprise M5000 Server
- Sun SPARC Enterprise M9000-64 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
SCF-8001-RP
Applies to:
Sun SPARC Enterprise M3000 Server - Version All Versions and later
Sun SPARC Enterprise M4000 Server - Version All Versions and later
Sun SPARC Enterprise M5000 Server - Version All Versions and later
Sun SPARC Enterprise M8000 Server - Version All Versions and later
Sun SPARC Enterprise M9000-32 Server - Version All Versions and later
All Platforms
Purpose
Provide additional information for message ID: SCF-8001-RP
Details
Predictive Self-Healing Article
Fatal error detected on a PCI-Express card in a PCI slot.
Type
- Fault
- fault.chassis.SPARC-Enterprise.io.pciex.card.fe
Severity
- Critical
Description
- A fatal error was detected on a PCI-Express card in a PCI slot.
Automated Response
- The PCI-Express card is deconfigured.
Impact
- The domain using the PCI slot is reset.
Suggested Action for System Administrator
- Schedule a repair action to replace the affected Field Replaceable Unit (FRU), the identity of which can be determined using fmdump -v -u EVENT_ID. Please consult the detail section of the knowledge article for additional information.
Details
- This message indicates a diagnosis of a fatal error detected on a PCI-Express card in a PCI slot.
The domain using the PCI slot is reset and the PCI-Express card is deconfigured.
The deconfiguration is not persistent across platform power cycles
or across Dynamic Reconfiguration operations.
The recommended service action for this event is to replace the PCI-Express card.
If the problem persists, proceed with the steps outlined below.
Step 1. Collect the fault message (use one of the following methods):
Single-line fault message displayed on the XSCF console:
Apr 12 16:42:36 san-dc3-1-0 fmd: SOURCE: sde, REV: 1.12, CSN: BE80601000
EVENT-ID: 5195e088-6f68-48fe-b97b-6e818a337a07
Refer to http://www.sun.com/msg/SCF-8001-RP for detailed information.
Complete fault message using 'fmdump -m' on the XSCF console:
MSG-ID: SCF-8001-RP, TYPE: Fault, VER: 1, SEVERITY: Critical
EVENT-TIME: Thu Apr 12 16:42:36 PDT 2007
PLATFORM: SPARC-Enterprise, CSN: BE80601000, HOSTNAME: san-dc3-1-0
SOURCE: sde, REV: 1.12
EVENT-ID:5195e088-6f68-48fe-b97b-6e818a337a07
DESC: A fatal error was detected on a PCI-Express card in a PCI slot.
Refer to http://www.sun.com/msg/SCF-8001-RP for more information.
AUTO-RESPONSE: The PCI-Express card is deconfigured.
IMPACT: The domain using the PCI slot is reset.
REC-ACTION: Schedule a repair action to replace the affected Field Replaceable Unit (FRU),
the identity of which can be determined using fmdump -v -u EVENT_ID.
Please consult the detail section of the knowledge article for additional information.
Step 2. Collect the output from the 'fmdump -v -u EVENT_ID' command
SPARC Enterprise platform example:
xscf> fmdump -v -u 5195e088-6f68-48fe-b97b-6e818a337a07
TIME UUID MSG-ID
Apr 12 16:42:36.7013 5195e088-6f68-48fe-b97b-6e818a337a07 SCF-8001-RP
100% fault.chassis.SPARC-Enterprise.io.pciex.card.fe
Problem in: hc:///chassis=0/iou=0/pcislot=0
Affects: -
FRU: hc://:product-id=SPARC-Enterprise:chassis-id=BE80601000:
server-id=san-dc3-1-0/component=/IOU#0/PCI#0
Step 3. Contact your Authorized Service Provider.
If you require additional information, please refer to Document 1002526.1.
Product
z-Other Server Models 1000-9999
Product_uuid
41751310-63d5-11d7-9179-89d0596b661d
Attachments