Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1021422.1
Update Date:2014-02-04
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1021422.1 :   SCF-8001-RP - Fatal error detected on a PCI-Express card in a PCI slot.  


Related Items
  • Sun SPARC Enterprise M8000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
  • Sun SPARC Enterprise M3000 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M9000-64 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  

PreviouslyPublishedAs
SCF-8001-RP


Applies to:

Sun SPARC Enterprise M3000 Server - Version All Versions and later
Sun SPARC Enterprise M4000 Server - Version All Versions and later
Sun SPARC Enterprise M5000 Server - Version All Versions and later
Sun SPARC Enterprise M8000 Server - Version All Versions and later
Sun SPARC Enterprise M9000-32 Server - Version All Versions and later
All Platforms

Purpose

Provide additional information for message ID: SCF-8001-RP

Details

Predictive Self-Healing Article
Fatal error detected on a PCI-Express card in a PCI slot.

Type

Fault
  fault.chassis.SPARC-Enterprise.io.pciex.card.fe

Severity

Critical

Description

A fatal error was detected on a PCI-Express card in a PCI slot.

Automated Response

The PCI-Express card is deconfigured.

Impact

The domain using the PCI slot is reset.

Suggested Action for System Administrator

Schedule a repair action to replace the affected Field Replaceable Unit (FRU), the identity of which can be determined using fmdump -v -u EVENT_ID. Please consult the detail section of the knowledge article for additional information.

Details

This message indicates a diagnosis of a fatal error detected on a PCI-Express card in a PCI slot.

The domain using the PCI slot is reset and the PCI-Express card is deconfigured.

The deconfiguration is not persistent across platform power cycles
or across Dynamic Reconfiguration operations.


The recommended service action for this event is to replace the PCI-Express card.

   If the problem persists, proceed with the steps outlined below.


Step 1. Collect the fault message (use one of the following methods):


   Single-line fault message displayed on the XSCF console:

   Apr 12 16:42:36 san-dc3-1-0 fmd: SOURCE: sde, REV: 1.12, CSN: BE80601000  
   EVENT-ID: 5195e088-6f68-48fe-b97b-6e818a337a07
   Refer to http://www.sun.com/msg/SCF-8001-RP for detailed information.

   Complete fault message using 'fmdump -m' on the XSCF console:

   MSG-ID: SCF-8001-RP, TYPE: Fault, VER: 1, SEVERITY: Critical    
   EVENT-TIME: Thu Apr 12 16:42:36 PDT 2007    
   PLATFORM: SPARC-Enterprise, CSN: BE80601000, HOSTNAME: san-dc3-1-0    
   SOURCE: sde, REV: 1.12    
   EVENT-ID:5195e088-6f68-48fe-b97b-6e818a337a07   
   DESC: A fatal error was detected on a PCI-Express card in a PCI slot.    
   Refer to http://www.sun.com/msg/SCF-8001-RP for more information.    
   AUTO-RESPONSE: The PCI-Express card is deconfigured.    
   IMPACT: The domain using the PCI slot is reset.    
   REC-ACTION: Schedule a repair action to replace the affected Field Replaceable Unit (FRU),
   the identity of which can be determined using fmdump -v -u EVENT_ID.    
   Please consult the detail section of the knowledge article for additional information.


Step 2. Collect the output from the 'fmdump -v -u EVENT_ID' command
   

   SPARC Enterprise platform example:
 
   xscf> fmdump -v -u 5195e088-6f68-48fe-b97b-6e818a337a07

         TIME                 UUID                                 MSG-ID
         Apr 12 16:42:36.7013 5195e088-6f68-48fe-b97b-6e818a337a07 SCF-8001-RP            
           100%  fault.chassis.SPARC-Enterprise.io.pciex.card.fe                   
                 
                 Problem in: hc:///chassis=0/iou=0/pcislot=0                     
                    Affects: -                         
                        FRU: hc://:product-id=SPARC-Enterprise:chassis-id=BE80601000:
                                   server-id=san-dc3-1-0/component=/IOU#0/PCI#0


Step 3. Contact your Authorized Service Provider.



If you require additional information, please refer to Document 1002526.1.



Product
z-Other Server Models 1000-9999

Product_uuid
41751310-63d5-11d7-9179-89d0596b661d


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback