Solution Type  Predictive Self-Healing Sure

Solution  1021847.1 :   SCF-8003-S4 - Error detected within a MBC chip during self-test.  


Related Items
  • Sun SPARC Enterprise M8000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
  • Sun SPARC Enterprise M3000 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M9000-64 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  

PreviouslyPublishedAs
SCF-8003-S4


Applies to:

Sun SPARC Enterprise M3000 Server - Version All Versions and later
Sun SPARC Enterprise M4000 Server - Version All Versions and later
Sun SPARC Enterprise M5000 Server - Version All Versions and later
Sun SPARC Enterprise M8000 Server - Version All Versions and later
Sun SPARC Enterprise M9000-32 Server - Version All Versions and later
All Platforms

Purpose

Provide additional information for message ID: SCF-8003-S4

Details

Predictive Self-Healing Article
Error detected within a MBC chip during self-test.

Type

Fault
  fault.chassis.SPARC-Enterprise.asic.mbc.test

Severity

Major

Description

An error was detected within the section of a MBC chip dealing with a specific XSB. This error is detected during self-test.

Automated Response

The XSB is deconfigured.

Impact

No immediate impact. The XSB is deconfigured.

Suggested Action for System Administrator

Schedule a repair action to replace the affected Field Replaceable Unit (FRU), the identity of which can be determined using fmdump -v -u EVENT_ID. Please consult the detail section of the knowledge article for additional information.

Details

An error was detected within the section of a MBC chip dealing with a specific XSB.

This error is detected during self-test.

This fault occurs while the MBC chip is being tested during:
 
   Board configuration (changing from Uni-XSB mode to Quad-XSB mode, or vice versa);
   Domain startup;
   Dynamic reconfiguration operations when the XSB is being DR-ed into a domain.

The XSB being tested is deconfigured.

Domains are unaffected by this fault, as no domains are using this XSB chip.


 

The recommended service action for this event is to schedule the replacement of the affected FRU.


Step 1. Collect the fault message (use one of the following methods):


   Single-line fault message displayed on the XSCF console:

   Mar 20 21:23:21 san-ff2-21-0 fmd: SOURCE: sde, REV: 1.12, CSN: 7860000772  
   EVENT-ID: c0a6595c-bf10-4c5b-a7aa-b62ce29f725f
   Refer to http://www.sun.com/msg/ SCF-8003-S4 for detailed information.


   Complete fault message using 'fmdump -m' on the XSCF console:

   MSG-ID:  SCF-8003-S4, TYPE: Fault, VER: 1, SEVERITY: Major
   EVENT-TIME: Tue Mar 20 21:23:21 UTC 2007
   PLATFORM: SPARC-Enterprise, CSN: 7860000772, HOSTNAME: san-ff2-21-0
   SOURCE: sde, REV: 1.12
   EVENT-ID: c0a6595c-bf10-4c5b-a7aa-b62ce29f725f
   DESC: An error was detected within the section of a MBC chip dealing with a specific
   XSB. This error is detected during self-test.
   Refer to http://www.sun.com/msg/SCF-8003-S4 for more information.
   AUTO-RESPONSE: The XSB is deconfigured.
   IMPACT: No immediate impact. The XSB is deconfigured.
   REC-ACTION: Schedule a repair action to replace the affected Field Replaceable Unit (FRU),
   the identity of which can be determined using fmdump -v -u EVENT_ID.
   Please consult the detail section of the knowledge article for additional information.


Step 2. Collect the output from the 'fmdump -v -u EVENT_ID' command

   
   SPARC Enterprise platform example:
 
   xscf> fmdump -v -u c0a6595c-bf10-4c5b-a7aa-b62ce29f725f

         TIME                 UUID                                 MSG-ID
         Mar 20 21:23:21.3206 c0a6595c-bf10-4c5b-a7aa-b62ce29f725f SCF-8003-S4
           100%  fault.chassis.SPARC-Enterprise.asic.mbc.test

                 Problem in: hc:///chassis=0/cmu=0/mbc=0
                    Affects: hc:///chassis=0/cmu=0/xsb=0
                        FRU: hc://:product-id=SPARC-Enterprise:chassis-id=7860000772:
                             server-id=san-ff2-21-0:
                             part=CA20393-B50X 001AA:revision=0101/component=/MBU_B


Step 3. Contact your Authorized Service Provider.