Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Fujitsu M10 PCI Expansion Unit : Reference


Reference Synopsis Last Modified Date
2246209.1 M12-i2c.device_pcibox_fanbp - I2C access failure to I2C devices (temperature sensors) on a fan backplane in a PCI expansion box 2017-10-17
2219067.1 M12-device.fan.tooslow_pcibox - The rotation speed of a PCI Expansion Box fan (including fans in fan trays or in PSUs) is incorrect 2017-08-23
2219058.1 M12-i2c.device_pcibox_linkbrd - I2C access failure to I2C devices on an link board in a PCI expansion box 2017-10-17
2219056.1 M12-io.pciex.pcibox.fe - Fatal error detected on a linkcard in a PCI slot or a linkbrd in a PCI expansion box 2017-10-17
2219054.1 M12-io.pciex.pcibox.se_linkcable - Error detected on a link cable connecting a link card and a PCI expansion box 2017-10-17
2219053.1 M12-domain.fe-unexpected-trap - An unexpected trap with unknown cause was detected by a CPU chip on a PPAR 2017-10-17
2219052.1 M12-i2c.device_pcibox_psu - I2C access failure to I2C devices on a Power Supply Unit (PSU) 2017-10-17
2219051.1 M12-i2c.device_linkcard - I2C access failure to I2C devices on the link card 2017-10-17
2219049.1 M12-io.pciex.pcibox.se_iob - Error detected on an IOB in a PCI expansion box 2017-10-17
2219046.1 M12-io.pciex.pcibox.fe_slot - Fatal error detected on a PCI Express slot in a PCI expansion box 2017-10-17
2219043.1 M12-i2c.device_pcibox_iob - I2C access failure to I2C devices on an IOB in a PCI expansion box 2017-10-17
2219041.1 M12-io.pciex.pcibox.fe_iob - Fatal error detected on a IOB in a PCI expansion box 2017-10-17
2219039.1 M12-device.missing_pcibox_linkbrd_linkcable - PCI expansion box link cable not connected 2017-10-17
2219037.1 M12-upset_config.linkcable_pcibox_linkbrd_linkcable - An upset occurred during powerup 2017-10-17
2219036.1 M12-upset_pcibox.firmware - A hard-to-diagnose failure of the PCI expansion box occurred 2017-10-17
2219035.1 M12-upset_config.psu_pcibox - Insufficient operable PCI expansion box PSUs detected 2017-10-17
2219034.1 M12-upset_config.fan_pcibox - The number of fans in a PCI expansion box are insufficient 2017-10-17
2219033.1 M12-i2c.device_pcibox_linkbrd_linkcable - I2C access failure to I2C devices on a link cable when starting a PCI expansion box 2017-10-17
2219032.1 M12-i2c.device.seeprom-corrupt_pcibox - Invalid data checksums in a FRU SEEPROM in a PCI expansion box 2017-10-17
2219019.1 M12-io.pciex.linkcard.flash - Problem detected writing to flash memory on a link card 2017-10-17
2219016.1 M12-io.pciex.pcibox.se - Error detected by a link card or link board in a PCI expansion box 2017-10-17
2218803.1 M12-device.fan.toofast_pcibox - Rotation speed of a PCI Expansion box fan has risen above the threshold. 2017-09-12
2218801.1 M12-device.inserted - the presence of a FRU is unexpectedly detected 2017-09-12
2218788.1 M12-env.power.loss - A power supply (PSU) detected a loss of AC power 2017-09-12
2218787.1 M12-env.temp.over - An overtemperature condition is detected by a temperature sensor 2017-09-12
2218782.1 M12-device.misconfig_pcibox_psu - An incorrect PSU was detected in a PCI expansion box 2017-09-12
2218778.1 M12-env.temp.over-fail - Overtemperature fault 2017-10-16
2218777.1 M12-env.temp.over-warn - An overtemperature warning condition is detected by a temperature sensor 2017-10-16
2218774.1 M12-device.fail_pcibox_iob_ddc - A DDC on an IOB in PCI expansion box signaled that it has failed 2017-09-11
2218773.1 M12-device.removed - the presence of a FRU detect signal suddenly disappears 2017-09-12
2218766.1 M12-upset_config.power - An upset occurred during powerup 2017-09-12
2218717.1 M12-power.power-off_pcibox_psu - XSCF failed to turn off the power to a PSU in a PCI expansion Box 2017-08-14
2218716.1 M12-power.power-off_pcibox_iob_ddc - A fault occurred when the XSCF tried to turn off the power of the DDC on an IOB 2017-08-14
2218480.1 M12-power.overvoltage_pcibox_iob - Overvoltage failure detected on an IOB in PCI expansion Box 2017-08-14
2218459.1 M12-io.pciex.switch.se - An error was detected within a PCIe switch 2017-08-14
1933615.1 M10-device.fan.tooslow@pcibox - The rotation speed of a PCI Expansion Box fan (including fans in fan trays or in PSUs) is incorrect 2016-01-06
1571505.1 Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-upset_ppar.config 2013-10-14
1571504.1 Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-upset_domain.post 2013-10-14
1571503.1 Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-upset_domain.panic 2015-01-12
1571502.1 Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-upset_config.power 2013-10-14
1571501.1 Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-upset_config.linkcable_pcibox_linkbrd_linkcable 2013-10-14
1571498.1 Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-unmatch_xbbox-id Instructions 2013-10-14
1571497.1 Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-env.temp.over-fail Instructions 2013-10-14
1571496.1 Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-device.missing_psu Instructions 2013-10-14
1571495.1 Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-device.missing_pcibox_linkbrd_linkcable 2013-10-14
1571494.1 Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-device.misconfig_pcibox_psu 2013-10-14
1571493.1 Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-device.misconfig_cmu_dimm 2013-10-14
1571441.1 Fujitsu M10-1/M10-4/M10-4S Servers: DraftSR: M10-device.misconfig Instructions 2013-10-15
1539402.1 M10-upset_pcibox.firmware - A hard-to-diagnose failure of the PCI expansion box occurred 2015-12-31
1539401.1 M10-upset_config.linkcable_pcibox_linkbrd_linkcable - An upset occurred during powerup 2016-01-04
1539398.1 M10-device.missing_pcibox_linkbrd_linkcable - PCI expansion box link cable not connected 2015-12-30
1537683.1 M10-upset_config.psu_pcibox - Insufficient operable PCI expansion box PSUs detected 2017-03-21
1537682.1 M10-upset_config.fan_pcibox - The number of fans in a PCI expansion box are insufficient 2015-12-31
1537680.1 M10-i2c.device.seeprom-corrupt_pcibox - Invalid data checksums in a FRU SEEPROM in a PCI expansion box 2015-12-30
1537679.1 M10-i2c.device_pcibox_linkbrd_linkcable - I2C access failure to I2C devices on a link cable when starting a PCI expansion box 2016-01-06
1537513.1 M10-i2c.device_pcibox_psu - I2C access failure to I2C devices on a Power Supply Unit (PSU) 2015-12-30
1537511.1 M10-i2c.device_pcibox_linkbrd - I2C access failure to I2C devices on an link board in a PCI expansion box 2017-03-21
1537510.1 M10-i2c.device_pcibox_fanbp - I2C access failure to I2C devices (temperature sensors) on a fan backplane in a PCI expansion box 2017-03-21
1537507.1 M10-i2c.device_linkcard - I2C access failure to I2C devices on the link card 2015-12-30
1537504.1 M10-io.pciex.linkcard.flash - Problem detected writing to flash memory on a link card 2015-12-31
1537492.1 M10-io.pciex.pcibox.se_linkcable - Error detected on a link cable connecting a link card and a PCI expansion box 2015-12-31
1537490.1 M10-io.pciex.pcibox.se_iob - Error detected on an IOB in a PCI expansion box 2015-12-31
1537488.1 M10-io.pciex.pcibox.se - Error detected by a link card or link board in a PCI expansion box 2015-12-31
1537486.1 M10-io.pciex.pcibox.fe_slot - Fatal error detected on a PCI Express slot in a PCI expansion box 2015-12-31
1537483.1 M10-i2c.device_pcibox_iob - I2C access failure to I2C devices on an IOB in a PCI expansion box 2015-12-30
1537480.1 M10-io.pciex.pcibox.fe_iob - Fatal error detected on a IOB in a PCI expansion box 2015-12-31
1537479.1 M10-io.pciex.pcibox.fe - Fatal error detected on a linkcard in a PCI slot or a linkbrd in a PCI expansion box 2015-12-31
1537469.1 M10-domain.fe-unexpected-trap - An unexpected trap with unknown cause was detected by a CPU chip on a PPAR 2015-12-30
1535254.1 M10-env.temp.over-fail - Overtemperature fault 2016-02-08
1535238.1 M10-env.temp.over-warn - An overtemperature warning condition is detected by a temperature sensor 2016-12-21
1534924.1 M10-env.temp.over - An overtemperature condition is detected by a temperature sensor 2016-01-06
1534912.1 M10-device.fan.toofast_pcibox - Rotation speed of a fan has risen above the threshold. 2015-12-30
1534882.1 M10-env.power.loss - A power supply (PSU) detected a loss of AC power 2016-01-06
1534879.1 M10-upset_config.power - An upset occurred during powerup 2015-12-31
1534828.1 M10-device.removed - A FRU's presence detect signal suddenly disappears 2015-12-30
1534813.1 M10-device.inserted - A FRU's presence is unexpectedly detected 2015-12-30
1534807.1 M10-device.misconfig_pcibox_psu - An incorrect PSU was detected in a PCI expansion box 2016-12-29
1534751.1 M10-device.fail_pcibox_iob_ddc - A DDC on an IOB in PCI expansion box signaled that it has failed 2015-12-30
1534068.1 M10-power.power-off_pcibox_psu - XSCF failed to turn off the power to a PSU in a PCI expansion Box 2015-12-31
1534066.1 M10-power.power-off_pcibox_iob_ddc - A fault occurred when the XSCF tried to turn off the power of the DDC on an IOB 2015-12-31
1533831.1 M10-power.overvoltage_pcibox_iob - Overvoltage failure detected on an IOB in PCI expansion Box 2015-12-31
1533822.1 M10-power.undervoltage_pcibox_iob - Undervoltage failure from an IOB in PCI expansion Box 2015-12-31
1533667.1 M10-power.warning_pcibox_psu - Undervoltage warning or overvoltage warning detected on a PSU in PCI expansion box 2015-12-31
1533664.1 M10-power.warning_pcibox_iob - Undervoltage warning or overvoltage warning detected on an IOB in PCI expansion box 2015-12-31
1533634.1 M10-io.pciex.switch.se - An error was detected within a PCIe switch 2017-03-27
  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.