How To
|
Non CAP Knowledge Documents
|
Last Modified Date
|
2179703.1 |
SAN Cisco Switch Interoperability Matrix - Compatibility With Oracle FS1-2 Storage and OPCA (Xsigo , OVN) |
2018-03-07
|
2123295.1 |
Oracle Virtual Networking (OVN/Xsigo) Environment Maintenance Activities |
2017-06-22
|
2104901.1 |
Fabric Interconnect (Xsigo) 1x10GE Ethernet Card Failed |
2017-10-02
|
2081967.1 |
XgOS 4.0 and Gen 1 Front Panels |
2015-11-24
|
2036979.1 |
How to Create a Remastered ISO With OVN (Xsigo) Drivers Slipstreamed in for VMware ESXi 6.0 |
2017-08-01
|
1958743.1 |
OSSI Product Installation: B62004 Storage - Switches - Group III BF1-4, Sun Datacenter Switch 36, 32-80 Port Switch Installations |
2017-04-10
|
1929995.1 |
Where to find the Source RPMs for Oracle Virtual Networking (OVN) Linux drivers |
2016-05-20
|
1574329.1 |
How to Install OVN Host Driver for Solaris 10 Update 11 |
2017-07-11
|
1574299.1 |
How to Install and Remove Oracle Virtual Networking (OVN) Host Drivers for Solaris 11 Update 1 Hosts |
2017-07-11
|
1565020.1 |
Oracle Virtual Networking (OVN) How to Install and Remove OVN Solaris 11 Drivers on SPARC and X86 Machine |
2017-07-11
|
1529319.1 |
How to Confirm if the OVN (Formerly Xsigo) Modules and Services are Running on Linux Machines |
2017-10-05
|
1528904.1 |
Changing the MTU of a vNIC |
2017-07-11
|
1528888.1 |
How to Add Oracle Virtual Network Linux Drivers to a Redhat Boot Disk |
2015-07-06
|
1528876.1 |
How to Inject OVN (Formerly Xsigo) ESXi 5.0 Host Drivers into VMware ESXi 5.0 Media |
2017-07-31
|
1528222.1 |
How to Verify that the Bootloader (GRUB) is Installed correctly |
2017-07-11
|
1528198.1 |
How To Identify the HCA Firmware and XgBOOT Version of a Running Host that is Connected to the Oracle Fabric Interconnect Device |
2017-01-12
|
1528122.1 |
How to Change the Management IP Address of the Oracle Fabric Interconnect Chassis from the CLI |
2017-05-31
|
1528072.1 |
Oracle Fabric Interconnect (Formerly Xsigo) :: Troubleshooting Suspected IB Connectivity Issues |
2017-08-01
|
1527256.1 |
How to Enable or Disable an IB Port on the Oracle Fabric Interconnect |
2017-09-04
|
1527051.1 |
How to Install and Remove OVN Host Drivers in ESXi 5.x |
2017-06-14
|
1526788.1 |
How to Determine if the IB Subnet Manager is Running on the Oracle Fabric Interconnect |
2017-07-03
|
1526480.1 |
How to Display the IP Address Given to a VLAN Tagged vNIC Interface |
2017-04-26
|
1526479.1 |
How to Collect Diagnostic Data From VMware ESX/ESXi and VirtualCenter Server |
2016-08-04
|
1526063.1 |
How to Configure Redundant vNIC Interfaces for a VMware ESX Host Connected to Oracle Fabric Interconnects (Formerly Xsigo) Chassis |
2017-08-01
|
1526062.1 |
How to Identify VMware ESX/ESXi and VMware VirtualCenter Server Versions |
2017-12-20
|
1519733.1 |
How to Inject ESX 5.2.1 Host Drivers into VMware ESXi 5.0U1 Media |
2017-07-11
|
1519308.1 |
How to Create an Oracle Virtual Networking SR (XSigo Product-Set) |
2015-12-18
|
1519048.1 |
How to change Oracle Fabric Interconnect vHBA Timeout value |
2016-07-01
|
1519043.1 |
ESXi 5.0 VMotion Configuration Best Practices for Oracle Virtual Networking (OVN -- Formerly Xsigo) Fabric Interconnnect Chassis |
2017-08-01
|
1519027.1 |
How to Upgrade the Oracle Fabric Interconnect Chassis Operating System |
2015-08-12
|
1519018.1 |
How to Install and Configure SNMP Traps and Log the Traps onto a Log File |
2017-06-26
|
1518946.1 |
How to Find the Version of OVN (Formerly Xsigo) Drivers Installed in Servers |
2017-08-01
|
1518936.1 |
How to Display FC Switches B2B (Buffer to Buffer) Credits |
2017-06-01
|
1518914.1 |
How to Collect Logs from a Linux Server that is Connected to Oracle Fabric Interconnect Chassis |
2017-07-17
|
1518906.1 |
HOWTO :: Check / Change IO Port Speed on the Oracle Fabric Interconnect (Formerly Xsigo) Device |
2017-08-01
|
1518900.1 |
Oracle Fabric Interconnect: How to Enable/Disable IGMP Snooping on a Ethernet IO Card |
2017-07-11
|
1518879.1 |
How to Generate Oracle Fabric Director Logs From Within Oracle Fabric Manager |
2017-07-11
|
1518875.1 |
How to Collect Logs from a Windows Server connected to Oracle Fabric Interconnect Chassis |
2017-07-11
|
1518873.1 |
How to Obtain the Host Server HCA Firmware Version from a Server running Windows Connected to Oracle Fabric Interconnect Chassis? |
2016-02-09
|
1518871.1 |
HOWTO :: Back up the Oracle Fabric Interconnect config and send the config to a remote archive location |
2017-07-11
|
1518868.1 |
With Xsigo Drivers, Link Speed Displays as Zero on the Windows 2008 R2 Hosts |
2017-07-11
|
1518857.1 |
How to Create a Remastered VMware ESX/ESXi 4.x ISO Containing Oracle Fabric Director Host Drivers |
2017-07-11
|
1518855.1 |
How to Tune xsvhba Queue Depth below or above Default Value of 16 |
2017-05-02
|
1518781.1 |
How to collect logs on ESX/i VMware Servers? |
2017-06-14
|
1518410.1 |
Best Practice for Moving a vnic From a 1GE IO Module to 10GE IO Module or Between Different Ports on an IO Module in Oracle Virtual Network (OVN - Formerly Xsigo) Fabric Interconnects |
2017-08-01
|
1518305.1 |
How to Create an ESXi 5.1 Remastered ISO Containing Oracle Virtual Networking (OVN) / Xsigo Drivers |
2017-08-01
|
1518181.1 |
Oracle Virtual Networking (OVN - Formerly Xsigo) How to Find Specific Configuration information Using ESXi 5.x Generated Logs |
2017-08-01
|
1517744.1 |
How to Configure Date and Time on Oracle Fabric Directors |
2017-07-11
|
1517733.1 |
How To Change 'admin' Password |
2017-07-11
|
1517712.1 |
How To Find HCA Firmware Version of a Host Connected to Oracle Fabric interconnects (Formerly Xsigo) |
2017-09-13
|
1517601.1 |
Oracle Fabric Interconenct (Formerly Xsigo) How to Change the Speed / Duplex Setting of a vNIC (Across all Operating Systems) |
2017-08-01
|
1517372.1 |
How to change the Root Password on the Oracle Fabric Interconnect Chassis (Formerly Xsigo) |
2017-08-07
|
1517366.1 |
How to Create/Upload Diagnostic Log File Bundle for an Oracle Fabric Interconnect (Formerly Xsigo) |
2017-08-01
|
1517356.1 |
What Level of Service is Needed to Configure a Syslog Server on the Oracle Fabric Interconnect (Formerly Xsigo)? |
2017-08-01
|
1517165.1 |
How to Find System UUID of a Host Connected to Oracle Fabric Interconnects (Formerly Xsigo Fabric Directors) |
2017-08-07
|
1517163.1 |
How to Get Host Channel Adapter (HCA) Board ID Connected to Oracle Virtual Networking (OVN - Formerly Xsigo) Fabric Interconnects |
2017-08-01
|
1517121.1 |
How to Enable Debugging for vhba/vn Agent Issues |
2017-07-11
|
1516700.1 |
How to Find ESXi 5.x Host Driver Version Installed |
2016-02-01
|
1516501.1 |
Do Oracle Fabric Interconnects (Formerly Xsigo) Support IPMI (Intelligent Platform Management Interface) |
2017-10-05
|
1516499.1 |
How To View Enable/Disable Confirmation Messages Before Deleting or Bringing Down a Port or Virtual Resource on Oracle Fabric Director CLI |
2017-07-11
|
1516497.1 |
How to Find MAC Address of Ethernet Port and IO Port of Oracle Fabric Interconnects (Formerly Xsigo Fabric Directors) |
2017-10-05
|
1516495.1 |
How to Find the HCA Firmware Versions on ESX/ESXi Hosts in Oracle Virtual Networking (OVN - Formerly Xsigo) Connected Hosts |
2017-10-05
|
1516493.1 |
OVN (Formerly Xsigo) How to Understand Operating System and Host Driver Version Along with HCA Firmware Version and HCA Driver Version in Displayed "physical-server" Output |
2017-07-31
|
1516478.1 |
How to Change the 'admin' password of Oracle Fabric Director from Oracle Fabric Manager |
2017-07-11
|
1516077.1 |
How to Globally Set CLI Idle Timeout |
2017-07-11
|
1516022.1 |
How to Detect a Bad (Failed) Front Panel HCA in Oracle Fabric Interconnects (OVN) Formerly Xsigo Fabric Director |
2018-03-01
|
1515049.1 |
OVN (Formerly Xsigo) How to Restart 'vhbaagent' Without Resetting IOP (IO Processor) |
2017-10-05
|
1514956.1 |
How to Restart MIMM Process on Oracle Fabric Interconnect (Formerly Xsigo Fabric Director) System Control Processor (SCP) |
2017-08-01
|
1514675.1 |
How To Back up Oracle Fabric Director Configuration Prior to Updating |
2017-10-19
|
1514611.1 |
How to Clear Screen When Logged in as 'admin' on Oracle Fabric Director |
2017-07-11
|