| Asset ID: |
1-71-1517163.1 |
| Update Date: | 2017-08-01 |
| Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1517163.1
:
How to Get Host Channel Adapter (HCA) Board ID Connected to Oracle Virtual Networking (OVN - Formerly Xsigo) Fabric Interconnects
| Related Items |
- Oracle Fabric Interconnect F1-15
- Oracle Fabric Interconnect F1-4
|
| Related Categories |
- PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
|
In this Document
Applies to:
Oracle Fabric Interconnect F1-4 - Version All Versions and later
Oracle Fabric Interconnect F1-15 - Version All Versions and later
Information in this document applies to any platform.
Goal
Learn how to find the Server HCA Board ID in order to identify which F/W or OptionROM version to install.
Solution
This process requires logging into the Fabric director as admin, then as root. Please note that the root account should not be used in normal administrative tasks on the Fabric Director.
1. Find the LID of a HCA using:
admin@kentucky[xsigo] show diagnostics ib-path george 1 ?
Here george is a server with a connectX HCA.
name lid/port width/speed SymErrs LnkRcov LnkDwnd RxErrs RxSwErr TxDisc TxPkts RxPkts XmtWait
-------------------------------------------------------------------------------------------------------------------------------------------------------------
george HCA-1 6/2 4X/2.5 Gbps 0 0 11 0 0 8 5892473 5891129 0
Xsigo Leaf 2 Switch 83/13 4X/2.5 Gbps 0 0 0 8 0 0 37342 37412 0
Xsigo Leaf 2 Switch 83/1 4X/5.0 Gbps 0 0 0 0 0 0 40546 39461 0
Xsigo Core Switch 81/13 4X/5.0 Gbps 0 0 0 0 0 0 39463 40553 0
Xsigo Core Switch 81/5 4X/5.0 Gbps 0 0 0 0 0 0 72858 34488 0
Xsigo Leaf 1 Switch 82/17 4X/5.0 Gbps 0 0 0 0 0 0 34495 72872 0
Xsigo Leaf 1 Switch 82/1 4X/5.0 Gbps 0 0 0 0 1 0 35 36 0
slot=1 vh2x8gcard 88/1 4X/5.0 Gbps 0 0 0 0 0 0 36 35 0
8 records displayed
2. Login as root to the chassis and execute command using LID:
kentucky:~# /opt/xsigo/xsigos/current/ofed/bin/xg_flint -d lid-6 query
-W- Failed to get ROM Version: Mellanox version string (mlxsign:) not found in ROM section.
Image type: ConnectX
FW Version: 2.9.1000 <-- Firmware Version
Rom Info: N/A
Device ID: 26418
Chip Revision: A0
Description: Node Port1 Port2 Sys image
GUIDs: 0002c90300028e9c 0002c90300028e9d 0002c90300028e9e 0002c90300028e9f
MACs: 0002c9028e9d 0002c9028e9e
Board ID: XgBoot_Version_2.8.7 (MT_0A50120005) <<-------------------- HCA Board ID (in parenthesis)
VSD: XgBoot_Version_2.8.7 <-- OptionROM Version
PSID: MT_0A50120005 <<-------------------- HCA Board ID
Attachments