Asset ID: 1-71-1517163.1
Update Date:2017-08-01
Keywords:

Solution Type  Technical Instruction Sure

Solution  1517163.1 :   How to Get Host Channel Adapter (HCA) Board ID Connected to Oracle Virtual Networking (OVN - Formerly Xsigo) Fabric Interconnects  


Related Items
  • Oracle Fabric Interconnect F1-15
  •  
  • Oracle Fabric Interconnect F1-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
  •  




In this Document
Goal
Solution


Applies to:

Oracle Fabric Interconnect F1-4 - Version All Versions and later
Oracle Fabric Interconnect F1-15 - Version All Versions and later
Information in this document applies to any platform.

Goal

 Learn how to find the Server HCA Board ID in order to identify which F/W or OptionROM version to install.

Solution

This process requires logging into the Fabric director as admin, then as root. Please note that the root account should not be used in normal administrative tasks on the Fabric Director.

1. Find the LID of a HCA using:

 

admin@kentucky[xsigo] show diagnostics ib-path george 1 ?

Here george is a server with a connectX HCA.

name                   lid/port    width/speed    SymErrs    LnkRcov    LnkDwnd    RxErrs    RxSwErr    TxDisc    TxPkts     RxPkts     XmtWait
-------------------------------------------------------------------------------------------------------------------------------------------------------------
george HCA-1           6/2         4X/2.5 Gbps    0          0          11         0         0          8         5892473    5891129    0
Xsigo Leaf 2 Switch    83/13       4X/2.5 Gbps    0          0          0          8         0          0         37342      37412      0
Xsigo Leaf 2 Switch    83/1        4X/5.0 Gbps    0          0          0          0         0          0         40546      39461      0
Xsigo Core Switch      81/13       4X/5.0 Gbps    0          0          0          0         0          0         39463      40553      0
Xsigo Core Switch      81/5        4X/5.0 Gbps    0          0          0          0         0          0         72858      34488      0
Xsigo Leaf 1 Switch    82/17       4X/5.0 Gbps    0          0          0          0         0          0         34495      72872      0
Xsigo Leaf 1 Switch    82/1        4X/5.0 Gbps    0          0          0          0         1          0         35         36         0
slot=1 vh2x8gcard      88/1        4X/5.0 Gbps    0          0          0          0         0          0         36         35         0
8 records displayed

 

 

2. Login as root to the chassis and execute command using LID:

 

kentucky:~# /opt/xsigo/xsigos/current/ofed/bin/xg_flint -d lid-6 query

-W- Failed to get ROM Version: Mellanox version string (mlxsign:) not found in ROM section.


Image type:      ConnectX
FW Version:      2.9.1000 <-- Firmware Version
Rom Info:        N/A
Device ID:       26418
Chip Revision:   A0
Description:     Node             Port1            Port2            Sys image
GUIDs:           0002c90300028e9c 0002c90300028e9d 0002c90300028e9e 0002c90300028e9f
MACs:                                 0002c9028e9d     0002c9028e9e
Board ID:        XgBoot_Version_2.8.7 (MT_0A50120005) <<-------------------- HCA Board ID (in parenthesis)
VSD:             XgBoot_Version_2.8.7 <-- OptionROM Version
PSID:            MT_0A50120005 <<-------------------- HCA Board ID


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.