![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1518906.1 : HOWTO :: Check / Change IO Port Speed on the Oracle Fabric Interconnect (Formerly Xsigo) Device
In this Document
Applies to:Oracle Fabric Interconnect F1-15 - Version All Versions to All Versions [Release All Releases]Oracle Fabric Interconnect F1-4 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalCheck or change IO Port Speed on the Oracle Fabric Interconnect SolutionThe below command will help you confirm the port speed on the IO Director: admin@chassis[xsigo] show diagnostics iop <IOP> port-info <port_number>
Look for the values: admin@chassis[xsigo] set vnic <vnicname.serverprofile> -if=none
admin@chassis[xsigo] set ethernet-port <card / port> up -rate=? Possible completions: [Available values] 100m 10g 1g autoNegotiate admin@chassis[xsigo] set ioport <card / port> down
admin@chassis[xsigo] set ioport <card / port> up
Attachments This solution has no attachment |
||||||||||||||
|