Solution Type  Technical Instruction Sure

Solution  2104901.1 :   Fabric Interconnect (Xsigo) 1x10GE Ethernet Card Failed  


Related Items
  • Oracle Fabric Interconnect F1-15
  •  
  • Oracle Fabric Interconnect F1-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
  •  




In this Document
Goal
Solution
References


Created from <SR 3-11089269761>

Applies to:

Oracle Fabric Interconnect F1-4 - Version All Versions to All Versions [Release All Releases]
Oracle Fabric Interconnect F1-15 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

Diagnose a suspected Ethernet card failure
 

Solution

IO Card reset after receiving 5 of the errors below, which indicates the card is rebooted only if spi4_snk_payld_dip4_err happens more than 5 times . The spi4_snk_payld_dip4_err does indicate something wrong on data path between XT and EZchip - which provided justification to replace this IO Module per OVN Engineering:

syslog.log:Jul 16 01:30:20 iop-4 klogd: [27834244.980000] XT: 399173:30:19:572629 =>[!!! XT Fatal]: xdev->xtstat.spi4_snk_payld_dip4_err

syslog.log:Jul 22 05:28:19 iop-4 klogd: [28366838.180000] XT: 399321:28:18:382692 =>[!!! XT Fatal]: xdev->xtstat.spi4_snk_payld_dip4_err

syslog.log.2:May 14 00:41:24 iop-4 klogd: [22388983.540000] XT: 397660:41:23:851489 =>[!!! XT Fatal]: xdev->xtstat.spi4_snk_payld_dip4_err

syslog.log.4:Dec 14 01:35:28 iop-4 klogd: [9351525.350000] XT: 394038:35:27:341652 =>[!!! XT Fatal]: xdev->xtstat.spi4_snk_payld_dip4_err

syslog.log.6:Jul 26 17:56:11 iop-4 klogd: [28439843.460000] XT: 390669:56:11:343276 =>[!!! XT Fatal]: xdev->xtstat.spi4_snk_payld_dip4_err

syslog.log.6:Aug 11 15:56:54 iop-4 klogd: [29815077.910000] XT: 391051:56:54:416926 =>[!!! XT Fatal]: xdev->xtstat.spi4_snk_payld_dip4_err

 



 

References

<BUG:21489339> - 1X10 GE IO MOD RESET DUE TO FATAL XT_EVENT_SPI_FAILURE
<NOTE:1517366.1> - How to Create/Upload Diagnostic Log File Bundle for an Oracle Fabric Interconnect