Asset ID: 1-71-1528122.1
Update Date:2017-05-31
Keywords:

Solution Type  Technical Instruction Sure

Solution  1528122.1 :   How to Change the Management IP Address of the Oracle Fabric Interconnect Chassis from the CLI  


Related Items
  • Oracle Fabric Interconnect F1-15
  •  
  • Oracle Fabric Interconnect F1-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
  •  




In this Document
Goal
Solution


Applies to:

Oracle Fabric Interconnect F1-15 - Version All Versions and later
Oracle Fabric Interconnect F1-4 - Version All Versions and later
Information in this document applies to any platform.

Goal

I need to change the management IP address of the  Oracle Fabric Interconnect chassis from the CLI. How do I do it?

Solution

Log on to the OVN chassis via a console session, and login as admin and use the following commands -

#set system management-interface -address="IP address/netmask (e.g.  192.168.3.56/24)" -default-gateway="Default gateway IP address" -ipconfig="default/static/dhcp" -netmask= "IP netmask (e.g 255.255.255.0)" -ntpservers="List of NTP servers (hostnames, comma separated)"

 

The below command will display the new IP address/netmask. It is recommended that the IP address is changed via a console session, as modifying the IP address via a SSH session will disconnect the session.

#show system interfaces

 