Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1528198.1
Update Date:2017-01-12
Keywords:

Solution Type  Technical Instruction Sure

Solution  1528198.1 :   How To Identify the HCA Firmware and XgBOOT Version of a Running Host that is Connected to the Oracle Fabric Interconnect Device  


Related Items
  • Oracle Fabric Interconnect F1-15
  •  
  • Oracle Fabric Interconnect F1-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
  •  




In this Document
Goal
Solution


Applies to:

Oracle Fabric Interconnect F1-4 - Version All Versions to All Versions [Release All Releases]
Oracle Fabric Interconnect F1-15 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

Determine the version of Firmware/XG Boot

Solution

From a root prompt use following command:
 
/opt/xsigo/xsigos/current/ofed/bin/xg_flint -d lid-<LID> query

1. Find the LID of a HCA using:

admin@kentucky[xsigo] show diagnostics ib-path george 1

name                   lid/port    width/speed    SymErrs    LnkRcov    LnkDwnd    RxErrs    RxSwErr    TxDisc    TxPkts     RxPkts     XmtWait

-------------------------------------------------------------------------------------------------------------------------------------------------------------

george HCA-1           6/2         4X/2.5 Gbps    0          0          11         0         0          8         5892473    5891129    0

Xsigo Leaf 2 Switch    83/13       4X/2.5 Gbps    0          0          0          8         0          0         37342      37412      0

Xsigo Leaf 2 Switch    83/1        4X/5.0 Gbps    0          0          0          0         0          0         40546      39461      0

Xsigo Core Switch      81/13       4X/5.0 Gbps    0          0          0          0         0          0         39463      40553      0

Xsigo Core Switch      81/5        4X/5.0 Gbps    0          0          0          0         0          0         72858      34488      0

Xsigo Leaf 1 Switch    82/17       4X/5.0 Gbps    0          0          0          0         0          0         34495      72872      0

Xsigo Leaf 1 Switch    82/1        4X/5.0 Gbps    0          0          0          0         1          0         35         36         0

slot=1 vh2x8gcard      88/1        4X/5.0 Gbps    0          0          0          0         0          0         36         35         0

8 records displayed

 

2. Login as root to chassis and execute command using LID.

kentucky:~# /opt/xsigo/xsigos/current/ofed/bin/xg_flint -d lid-6 query

-W- Failed to get ROM Version: Mellanox version string (mlxsign:) not found in ROM section.

Image type:      ConnectX
FW Version:      2.9.1000 ß Firmware Version
Rom Info:        N/A
Device ID:       26418
Chip Revision:   A0
Description:     Node             Port1            Port2            Sys image
GUIDs:           0002c90300028e9c 0002c90300028e9d 0002c90300028e9e 0002c90300028e9f
MACs:                                 0002c9028e9d     0002c9028e9e
Board ID:        XgBoot_Version_2.8.7
VSD:             XgBoot_Version_2.8.7
PSID:            MT_0A50120005


Attachments