Asset ID: |
1-71-1528198.1 |
Update Date: | 2017-01-12 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1528198.1
:
How To Identify the HCA Firmware and XgBOOT Version of a Running Host that is Connected to the Oracle Fabric Interconnect Device
Related Items |
- Oracle Fabric Interconnect F1-15
- Oracle Fabric Interconnect F1-4
|
Related Categories |
- PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
|
In this Document
Applies to:
Oracle Fabric Interconnect F1-4 - Version All Versions to All Versions [Release All Releases]
Oracle Fabric Interconnect F1-15 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
Determine the version of Firmware/XG Boot
Solution
From a root prompt use following command:
/opt/xsigo/xsigos/current/ofed/bin/xg_flint -d lid-<LID> query
1. Find the LID of a HCA using:
admin@kentucky[xsigo] show diagnostics ib-path george 1
name lid/port width/speed SymErrs LnkRcov LnkDwnd RxErrs RxSwErr TxDisc TxPkts RxPkts XmtWait
-------------------------------------------------------------------------------------------------------------------------------------------------------------
george HCA-1 6/2 4X/2.5 Gbps 0 0 11 0 0 8 5892473 5891129 0
Xsigo Leaf 2 Switch 83/13 4X/2.5 Gbps 0 0 0 8 0 0 37342 37412 0
Xsigo Leaf 2 Switch 83/1 4X/5.0 Gbps 0 0 0 0 0 0 40546 39461 0
Xsigo Core Switch 81/13 4X/5.0 Gbps 0 0 0 0 0 0 39463 40553 0
Xsigo Core Switch 81/5 4X/5.0 Gbps 0 0 0 0 0 0 72858 34488 0
Xsigo Leaf 1 Switch 82/17 4X/5.0 Gbps 0 0 0 0 0 0 34495 72872 0
Xsigo Leaf 1 Switch 82/1 4X/5.0 Gbps 0 0 0 0 1 0 35 36 0
slot=1 vh2x8gcard 88/1 4X/5.0 Gbps 0 0 0 0 0 0 36 35 0
8 records displayed
2. Login as root to chassis and execute command using LID.
kentucky:~# /opt/xsigo/xsigos/current/ofed/bin/xg_flint -d lid-6 query
-W- Failed to get ROM Version: Mellanox version string (mlxsign:) not found in ROM section.
Image type: ConnectX
FW Version: 2.9.1000 ß Firmware Version
Rom Info: N/A
Device ID: 26418
Chip Revision: A0
Description: Node Port1 Port2 Sys image
GUIDs: 0002c90300028e9c 0002c90300028e9d 0002c90300028e9e 0002c90300028e9f
MACs: 0002c9028e9d 0002c9028e9e
Board ID: XgBoot_Version_2.8.7
VSD: XgBoot_Version_2.8.7
PSID: MT_0A50120005
Attachments