Goal
Solution


Applies to:

Oracle Fabric Interconnect F1-15 - Version All Versions to All Versions [Release All Releases]
Oracle Fabric Interconnect F1-4 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

 How to troubleshoot suspected IB connectivity issues

Solution

 In Xsigo XgOS versions prior to 2.8.5 you have to login to the IO Director as user 'root' to run:

# ibcheckerrors
# ibclearerrors
 
In XgOS versions 2.8.5 and above you can login as user 'admin' and run these commands:

Command below will show 'ibcheckerrors' in output:
# show diagnostics ofed

This command is the same as 'ibclearerrors':
# set diagnostics ib-clear-counters

Show IB errors for server plus IO Card#:
# show diagnostics ib-path <servername> IOP#