Applies to:Oracle Fabric Interconnect F1-15 - Version All Versions and laterOracle Fabric Interconnect F1-4 - Version All Versions and later Information in this document applies to any platform. GoalLearn how to find the HCA Firmware version on a host with Xsigo Host drivers installed and also from the Oracle Fabric Director CLI. SolutionThis solution lists the commands to display the HCA Firmware version from both the Oracle Fabric Director and the Host itself. #cd /proc/driver/xscore/xcpm/ports/
/proc/driver/xscore/xcpm/ports # ls 2c903000f6d4f 2c903000f6d50
/proc/driver/xscore/xcpm/ports # cat 2c903000f6d4f
Device name: mlx4_0 Device FW Version: 2.7.0 Port: 1
From the Oracle Fabric Director: admin@karnataka[xsigo] show physical-server LOGO2 name guid descr port os version server-profile ------------------------------------------------------------------------------------------------------------------------------------------------------------ LOGO2 2c9030010d345 karnataka:ServerPort12 Windows/6.0.6001/x64-3.0.6.2 2.7.0/2.1.1 1 record displayed admin@karnataka[xsigo]
-- OR -- admin@karnataka[xsigo] show physical-server LOGO2 hca lid guid board-id firmware-version hardware-version option-version ------------------------------------------------------------------------------------------------------------------------------------------------------------ lid-31 0002c9030010d344 MT_0A50120005 2.7.0 A0 unknown 1 record displayed admin@karnataka[xsigo]