Goal
Solution


Applies to:

Oracle Fabric Interconnect F1-4 - Version All Versions to All Versions [Release All Releases]
Oracle Fabric Interconnect F1-15 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

 Learn how to perform IB diagnostic steps on Oracle Fabric Interconnect during Fabric setup.

Solution

 Here is a rough guideline of how to bring-up a fabric.

1. Cable the IB fabric.
2. Power on a "manageable section" of the fabric.
3. Clear counters when logged into Fabric Director as user 'admin':

#set diagnostics ib-clear-counters

4. Watch the SM (Subnet Manager) sweep and look for errors.  Run the command 'showlog opensm.log' to watch SM sweep.  Additionally run this command:

#show diagnostics ofed

Look for section titled 'ibnetdiscover', in the output of above command and note any symbol or other errors as well as any 'linkwidth' issues.  Any linkwidth negotiating at 1x instead of 4x means a possible bad IB cable, bad IB port, bad HCA, or poorly seated IB cable or HCA.


5. If the SM sees errors on an idle fabric, fix errors, go back to step "3".
6. Clear counters.

#set diagnostics ib-clear-counters


7. Run traffic on all nodes powered on (ideally to all other nodes).
8. Watch the SM log and sweep and look for errors - (showlog opensm.log)
9. If errors, fix the errors, and go back to step "5".

10. If the fabric is not all powered on, power on an additional "manageable section" of the fabric, go to step 3.
11. Done!