Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1519048.1
Update Date:2016-07-01
Keywords:

Solution Type  Technical Instruction Sure

Solution  1519048.1 :   How to change Oracle Fabric Interconnect vHBA Timeout value  


Related Items
  • Oracle Fabric Interconnect F1-15
  •  
  • Oracle Fabric Interconnect F1-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Oracle Virtual Networking
  •  




In this Document
Goal
Fix


Applies to:

Oracle Fabric Interconnect F1-4 - Version All Versions and later
Oracle Fabric Interconnect F1-15 - Version All Versions and later
Information in this document applies to any platform.

Goal

How to change Oracle Fabric Interconnect vHBA Timeout value

Fix

Login to the Oracle Fabric Interconnect Chassis as user 'admin' and run the commands below:

set fc-port {* | <slot>/<port>} -fc-link-down-timeout={<number> | default}
set fc-port {* | <slot>/<port>} -fc-target-port-down-timeout={<number> | default}

The default timeout value is listed below with the command:

admin@xavier[xsigo] show fc-port 1/2 -detail
-------------------------------------------------------------------------------
name 1/2
type sanFcPort
state up/up
descr
wwnn 50:01:39:71:00:0B:90:03
wwpn 50:01:39:70:00:0B:90:03
rate auto/4Gbps
frame-size 2048/2048
exec-throttle 65535
int-delay 1000
fc-link-down-timeout 30
login-retry 8
login-timeout 4
fc-target-port-down-timeout 30
topo F
loop-delay 5
tape-support true
sfp-type 4G
vhbas 7
-------------------------------------------------------------------------------
1 record displayed

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback