![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1517137.1 : OVN (Formerly Xsigo) How To Perform Firmware Upgrade of Mellanox FabricIT IS5030 (IS36-SWITCH-QDR-MG) Switch
In this Document
Applies to:Oracle Fabric Interconnect F1-15 - Version All Versions and laterOracle Fabric Interconnect F1-4 - Version All Versions and later Information in this document applies to any platform. GoalTo learn how to upgrade External IS36 IB Expansion Switch Firmware SolutionIf switch already has an IP address skip to section. "Starting a WebUI Connection to the Switch" Managed (Internally managed) Switches Step 1. Connect the host PC RS232 connector to the CONSOLE port of the switch using the supplied cable Step 2. Configure a serial terminal program (for example, HyperTerminal, Minicom, or Tera Term) on your host PC with the settings described in Table 1.
Step 3. Login (from serial terminal program) as admin and use admin as password. This starts the Mellanox configuration wizard. Step 4. Go through the Mellanox configuration wizard. Table 4 shows an example of a wizard session. Step 4. Go through the Mellanox configuration wizard. Table 2 shows an example of a wizard session. Starting a WebUI Connection to the Switch Step 1. Set up an Ethernet connection between the switch and a local network machine ("the remote machine" henceforth) using a standard RJ-45 connector. Step 2. Start a Web browse – Internet Explorer 7.0 or Mozilla Firefox 3.0. Step 3.Enter as URL the following: http://<switch_IP_address> where <switch_IP_address> is the IP address of the switch or its DNS name. Step 5. Select FabricIT Upgrade Step 6. Download the current firmware img file from the following URL. http://support.mellanox.com/ftp/versions/current/Software/FabricIT/EFM/M405EX/Current/ Step 7. Under Install New Image to (non-active) Partition n
Attachments This solution has no attachment |
||||||||||||||
|