![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 1516495.1 : How to Find the HCA Firmware Versions on ESX/ESXi Hosts in Oracle Virtual Networking (OVN - Formerly Xsigo) Connected Hosts
In this Document
Applies to:Oracle Fabric Interconnect F1-15 - Version All Versions and laterOracle Fabric Interconnect F1-4 - Version All Versions and later Information in this document applies to any platform. GoalUnderstand two methods used for finding the HCA Firmware version on ESX/ESXi hosts Solution1st method Any one of the ports under XCPM folder should give you the Device FW version - On the ESXi host as user root, run command below: #cat /proc/driver/xscore/xcpm/ports/<2c903000f3f20>
Device name: mlx4_0 Device FW Version: 2.9.1000 Port: 2 Port GUID: 0x2c903000f3f20 Port PhysState: 5: Link Up Port State: PORT_ACTIVE Port LID: 28 Port SM LID: 1 Port MTU: 4 (2048) Port Link Layer: Infiniband Port XDS LID: 24 Port XDS GUID: 0x139702010002f1 ------------------------------------------------------
/proc/driver/mlx4/0000:05:00.0 # cat FW_Ver 0x2000903e8
Attachments This solution has no attachment |
||||||||||||||
|