Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

SPARC T5-4 : Problem Documents


Problem Document Synopsis Last Modified Date
2391782.1 ILOM Out-of-Memory due to Nessus security scan 2018-04-26
2370600.1 ILOM webgo corefiles + fault ILOM-8000-JV 2018-04-20
2368595.1 T4/T5 S11 System faults on the PCI/SCSI bus with a PCIEX-8000-0A and MPTSAS firmware errors 2018-03-05
2313453.1 SNMP fails after OHMP upgrade to 2.4.1 2017-10-02
2301011.1 ILOM Reboots due to Out of Memory or Hangs after ILOM 3.2.4 fixes 2018-05-07
2286032.1 Panic Due To mutex_destroy: not owner When Attempting To Offline, Hotplug, Or Unconfigure An Emulex Fibre Channel HBA Shutdown Due To Adapter Hardware Error 2018-01-17
2273241.1 SPARC T5-4 stuck on Reconfiguring System (Hostconfig) after passing POST 2017-06-08
2246285.1 T5-4/T5-8 I2C bus sensor on a PCI Carrier may cause fans to run at max RPM 2017-03-24
2213399.1 A number of SPARC T5 servers shipped without fully completing the factory's sys-unconfig process. This resulted in failure to setup the HOST preinstalled OS 2018-03-28
2211740.1 Failing to add a new host config to SP using ldm add-config command 2018-05-01
2208651.1 Troubleshooting high fan speed in T-series systems 2018-05-22
2189960.1 Firmware upgrade with existing faults from prior ILOM rev 3.2.6 to after results in misclassified Subsystem on T4-x, T5-x, & T7-x 2018-01-12
2164409.1 SPARC: SMF-8000-YX: system/management/firmware-check:default is unavailable 2017-10-05
2136834.1 M10-x, Mx-32,T4-x, T5-x Servers: ldmd_start Fails with Error "timeout waiting for op HVctl_op_hello" 2018-02-12
2135699.1 Cannot Log In To Service Processor (SP) On T3/T4/T5, T5x20, T5x40 Servers: Too many users are logged in 2018-03-06
2108027.1 Solaris 11 systems showing a different Serial Number when activating ASR 2016-02-23
2079496.1 FC HBA PCI Card Not Detected by Solaris After T5-4 Firmware Upgrade 2018-03-07
2070764.1 300GB, 600GB, 900GB, and 1.2 TB Disk Firmware Upgrade to Address Unrecoverable Read Errors in SPARC Platforms. 2017-07-17
2061696.1 VTS tests exit with exit code 93 when Hardware Management Pack prior revision 2.3.2.4 installed 2017-05-02
2019196.1 LUN creation on an IBM Storage DS8000 can be delayed recognized by the server 2018-03-07
1999001.1 LUN Status Failed From OPs Center 2018-02-08
1986390.1 Solaris 11 - 16GB Qlogic FC HBA - WARNING: qlt(x): unknown devid(2031), failing attach 2018-05-22
1982289.1 SPARC T5-4 systems may suffer a power glitch during an ac power cord cycle (disconnecting/connecting power cables) when parallel boot and host auto power on are been enabled (which are the default values) 2018-03-08
1944663.1 T5xx0-T8 Servers: Service Processor Network connectivity lost without auto negotiation on Ethernet port 2018-03-13
1938327.1 Installing Solaris Via Install Server or Jumpstart Server Over VLAN Fails With "Connection timed out" 2018-03-06
1930869.1 GM / vbsc.log flooded with "DEBUG: failed to check for data on "ipmi" LDC because it reset" 2018-04-04
1924039.1 How To Set Qlogic CNA Personality - Sun Storage Qlogic 16Gb FC HBA Universal / 10GB FCoE - Report SFP: Invalid, Reason: 1000 at the OBP 2018-04-03
1923776.1 Oracle Critical Thread (CT) Optimizations in SPARC Sun4v Based Servers to Enhance Single-Threaded Performance 2017-12-04
1915487.1 HV Abort on guest domain shutdown 2017-10-05
1901609.1 T5-4 : SPT-8000-1Q : FMD faults on multiple components after firmware upgrade. 2017-09-13
1672818.1 Troubleshooting "Fatal error has occured in: PCIe fabric" panics on TX-X servers 2017-10-04
1669763.1 SPARC T5 Running Solaris 10 May Panic When Connecting An External USB Tape Drive 2018-02-06
1645197.1 ILOM NET MGT Does Not Connect To Network 2017-08-16
1643847.1 Primary disk label corrupt 2017-03-17
1643464.1 [SPARC T3/T4/T5 and T7] OBP reports "One or more resources have been retired, please run 'show faulty' on the SP" on console 2017-10-05
1643445.1 [SPARC T4/T5] ILOM 3.2.1.7: WEB GUI : Maintenance Firmware Upgrade fails on IE10 2017-10-05
1642066.1 ixgbe interface faulted because of message "Problem: Network adapter has been stopped because it has overheated" 2017-07-11
1634139.1 Non-Oracle GBIC (transceiver) causes no OS NIC data or improper operation 2017-12-13
1627528.1 T-Series servers with LSI106x(e) (mpt driver) / LSI2x08 (mpt_sas driver) controllers reports "Command Timeout" for all internal disks (HDD/SSD) Caused by mpt/mpt_sas driver bug 2018-03-06
1626351.1 [SPARC T5] "virtinfo -a" displays "unknown" Control Domain and Chassis Serial# 2017-07-26
1621104.1 Solaris 11 ISC DHCP: SPARC T5/T4 and T3 server fails network boot/network AI install at OBP with BOOTP/DHCP timeout 2017-10-05
1620574.1 SPARC T5:S10 U11: SPT-8000-KQ :Identifying which Power Supply has a faulty fan in Solaris 2017-10-05
1617956.1 I/O SERD threshold values are set too low and may result in PCIEX-8000-J5, PCIEX-8000-YJ and PCIEX-8000-KP faults. 2017-08-22
1614738.1 [SPARC T4/T5/M5 and M6] FMA I/O retirement : PCI devices can be seen from OBP but disappear when System Boots up into Solaris 2018-05-01
1614157.1 SPARC T5-4/T5-8 Servers may see "Ops failing fault.ops.chassis.voltage.fail on FRU /SYS/MB" when Upgrading to System Firmware 9.1.1 2017-11-15
1613667.1 ILOM 3.2 NO LONGER sends the ILOM hostname to DHCP server on SPARC T3-x, SPARC T4-x, and SPARC T5-x servers 2017-11-14
1613206.1 SPARC T5-X at System Firmware 9.1.1 Downgrade or Re-flash firmware using BUI method may fail. 2017-05-09
1612672.1 SPARC T5 System :FMA reports SUNOS-8000-FU or SUNOS-8000-J0 due to ereport.io.pciex.rc.ce-msg 2018-05-01
1604929.1 PCIEX-8000-MH causing AMBER LED On, on T5-x Systems 2017-08-16
1603333.1 Identify cause of PCIEX-8000-0A PCIe event 2017-10-05
1600497.1 Description: A Device Necessary To Support A Configuration Has Failed. 2017-10-05
1594669.1 Minimum Solaris version for Oracle VM for SPARC 3.1 on SPARC T5 2017-10-05
1588217.1 ILOM: Status of Hard Drives Not Available on SPARC T3/T4/T5 Systems 2017-12-13
1586616.1 Solaris 10 T4/T5 server with KU 147440-04 or later can hang or have performance issue with DISM 2017-09-23
1586490.1 Unable To configure ILOM Net MGMT port - Unable to get network management property 2018-01-22
1581137.1 System Fan Running At Full Speed Every 5 Min 2017-10-05
1581135.1 Oracle VM guest bind failure due to Direct I/O device in an Unknown (UNK) state. 2017-10-05
1580033.1 SP Resets on T5xx0, T3, T4, T5 and M5 Systems May Overwrite a User-Land Solaris Memory Page Causing In-Memory Corruption 2018-01-22
1578024.1 ereport.io.usb.epse USB endpoint stall event 2017-10-05
1574004.1 SPARC T5 fails to power on with ILOM FMA diagnosing SPSUN4V-8000-RQ / fault.chassis.no-cpus-signed-on 2018-05-01
1568920.1 SPARC T5-4/T5-8 persistently generates the following event PCIEX-8000-V2 even after replacing the HBA card 2018-04-25
1567072.1 Workaround Options for Guest Domains Running Solaris 11.1.7.5.0 (or greater) on T5 and M5 Systems and Live Migration 2016-09-08
1559361.1 T5-4/T5-8 : PCIE fabric error panic or/and ereports on QLogic Fiber Channel HBA (Pallene) populated slots 2018-04-25
1549537.1 SP Filesystem Full, SPT-8000-ED reported 2017-10-05
1531113.1 T-Series Servers: Solaris messages files filled with SC Alert: Audit events (Open, Close, Activate Session) 2017-10-05
1517032.1 T3-x, T4-x, T5-x, T7-x: Unrecognized Chassis: This Module Is Installed In An Unknown Or Unsupported Chassis. 2018-03-05
  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.