![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1600497.1 : Description: A Device Necessary To Support A Configuration Has Failed.
In this Document
Created from <SR 3-7997799041> Applies to:SPARC T5-4 - Version All Versions to All Versions [Release All Releases]SPARC T5-8 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsSPT-8000-1Q "Chassis Device Fail" triggered due to POST I2C test fault resulting in a generic FMA event; {DATE} 12:20:56 3de49102-1e0f-e8c8-dfd5-d63499590f17 SPT-8000-1Q Critical Problem Status : solved ---------------------------------------- FRU Description : A device located in the chassis that supports the blade server Response : The service required LED on the chassis that supports the blade Impact : Loss of power or cooling redundancy may have adverse impact on Action : Please refer to the associated reference document at CauseTest failure shown above which occurred when issuing a read request to a device on the I2C bus, reported by FMA on the Service Processor. {snapshot}/fma/@persist@faultdiags@ereports.log {DATE} ereport.chassis.post.dev.test-fail@/SYS/MB SolutionPower cycle the system on first event, if repeat event occurs escalate the issue to Oracle Support. Attachments This solution has no attachment |
||||||||||||||||
|