Solution Type  Problem Resolution Sure

Solution  1614157.1 :   SPARC T5-4/T5-8 Servers may see "Ops failing fault.ops.chassis.voltage.fail on FRU /SYS/MB" when Upgrading to System Firmware 9.1.1  


Related Items
  • SPARC T5-4
  •  
  • SPARC T5-8
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

SPARC T5-8 - Version All Versions to All Versions [Release All Releases]
SPARC T5-4 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

SPARC T5-4/T5-8 Servers may see the following ereport messages in the ILOM snapshot under the fma directory:

 

2014-01-08/14:10:41  ereport.chassis.tli.ok@/SYS


2014-01-08/14:11:57  ereport.chassis.voltage-unc-ghi@/SYS/MB
                         detector  = /SYS/MB/V_+12V_3V3_STBY_OBPS
                         hidden    = true
                         reading   = 11.9404
                         threshold = 11.844

2014-01-08/14:13:49  ereport.chassis.voltage-unc-ghi@/SYS/MB
                         detector  = /SYS/MB/V_+12V_3V3_STBY_OBPS
                         hidden    = true
                         reading   = 11.9385
                         threshold = 11.844

2014-01-08/14:14:15  ereport.chassis.voltage-unc-ghi@/SYS/MB
                         detector  = /SYS/MB/V_+12V_3V3_STBY_OBPS
                         hidden    = true
                         reading   = 11.9385
                         threshold = 11.844

2014-01-08/14:19:07  ereport.chassis.tli.ok@/SYS

2014-01-08/14:19:28  ereport.sp.boot-cold@/SYS/MB/SP

2014-01-08/14:20:23  ereport.chassis.voltage-unc-ghi@/SYS/MB
                         detector  = /SYS/MB/V_+12V_3V3_STBY_OBPS
                         hidden    = true
                         reading   = 11.9434
                         threshold = 11.844

Cause

ILOM software regression.  Issue only seen with System Firmware 9.1.1

 

This is related to bug 18070361

Solution

Fixed in system firmware to 9.1.2.d


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback