![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1614157.1 : SPARC T5-4/T5-8 Servers may see "Ops failing fault.ops.chassis.voltage.fail on FRU /SYS/MB" when Upgrading to System Firmware 9.1.1
In this Document
Applies to:SPARC T5-8 - Version All Versions to All Versions [Release All Releases]SPARC T5-4 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsSPARC T5-4/T5-8 Servers may see the following ereport messages in the ILOM snapshot under the fma directory:
2014-01-08/14:10:41 ereport.chassis.tli.ok@/SYS
CauseILOM software regression. Issue only seen with System Firmware 9.1.1
This is related to bug 18070361 SolutionFixed in system firmware to 9.1.2.d Attachments This solution has no attachment |
||||||||||||||||
|