![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1581137.1 : System Fan Running At Full Speed Every 5 Min
In this Document
Created from <SR 3-7566729561> Applies to:SPARC T5-8 - Version All Versions and laterSPARC T5-4 - Version All Versions and later Information in this document applies to any platform. SymptomsHigh fan speed reported on a single SPARC T5-4 system CauseThe Intelligent Fan Controller (IFC) prior to System FW 9.0.2.g would increase system fan speeds to 100% in response to environmental changes, causing fan tach oscillations. From System FW 9.0.2.g onwards the Intelligent Fan Controller (IFC) will increment fan speed changes instead. SolutionInstall System FW 9.0.2.g (patchID 17019069) or later References<NOTE:1581135.1> - Oracle VM guest bind failure due to Direct I/O device in an Unknown (UNK) state.<BUG:16887730> - IMPROVE T5-8 AND T5-4 IFC FAN CONTROL ALGORITHM FOR BETTER FAN SPEED CONTROL Attachments This solution has no attachment |
||||||||||||||||||
|