Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1581137.1
Update Date:2017-10-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  1581137.1 :   System Fan Running At Full Speed Every 5 Min  


Related Items
  • SPARC T5-8
  •  
  • SPARC T5-4
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-7566729561>

Applies to:

SPARC T5-8 - Version All Versions and later
SPARC T5-4 - Version All Versions and later
Information in this document applies to any platform.

Symptoms

High fan speed reported on a single SPARC T5-4 system

Cause

The Intelligent Fan Controller (IFC) prior to System FW 9.0.2.g would increase system fan speeds to 100% in response to environmental changes, causing fan tach oscillations.

From System FW 9.0.2.g onwards the Intelligent Fan Controller (IFC) will increment fan speed changes instead.

Solution

Install System FW 9.0.2.g (patchID 17019069) or later

References

<NOTE:1581135.1> - Oracle VM guest bind failure due to Direct I/O device in an Unknown (UNK) state.
<BUG:16887730> - IMPROVE T5-8 AND T5-4 IFC FAN CONTROL ALGORITHM FOR BETTER FAN SPEED CONTROL

Attachments
This solution has no attachment