Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun SPARC Enterprise T5220 Server : Problem Documents


Problem Document Synopsis Last Modified Date
2368354.1 "Could not chdir to home directory : No such file or directory" in System firmware revision 7.4.10.a and 7.4.11 2018-03-02
2179850.1 Solaris Scsi Error - Sense Key: Aborted_Command - ASC: 0x44 (internal target failure), ASCQ: 0x0, FRU: 0x0 2018-03-07
2161328.1 ILOM BUI reports "Invalid session" after Firmware upgrade 2017-12-07
2153885.1 Error during POST on T5220 Server: /SYS/MB/CMP0/NIU0 or/and NIU1 Forced fail (POST) 2018-05-17
2135699.1 Cannot Log In To Service Processor (SP) On T3/T4/T5, T5x20, T5x40 Servers: Too many users are logged in 2018-03-06
2126841.1 Oracle Hardware Management Pack's (OHMP) fwupdate command fails to install older disk firmware patches. 2017-12-14
2112377.1 SunFire T5x0 : ILOM serial redirection fails: Certificates does not conform to algoritm 2018-02-06
2108027.1 Solaris 11 systems showing a different Serial Number when activating ASR 2016-02-23
2094200.1 T5120, T5220, T5140, T5240: Server powered itself off and refuses to power on due to "Chassis cover removed." 2018-03-06
2070764.1 300GB, 600GB, 900GB, and 1.2 TB Disk Firmware Upgrade to Address Unrecoverable Read Errors in SPARC Platforms. 2017-07-17
2022566.1 After creating a patched Alternate Boot Environment (ABE) via Live Upgrade, attempts to boot off ABE hang 2015-06-19
1988705.1 Does Solaris scadm ALOM control utility exist on T1000/T2000/T5120/T5220/T5140/T5240 Servers? 2018-05-17
1951504.1 DAT-72 - ASC: 0x0 ASCQ: 0x2 : Volume_Overflow, End-of-Media Detected, End of Partition/Medium Detected 2017-08-16
1950178.1 T5120/T5220/T5140/T5240 and Netras System Shuts Down Due to Sensor Errors on /T_TCORE and /T_BCORE 2017-05-01
1944663.1 T5xx0-T8 Servers: Service Processor Network connectivity lost without auto negotiation on Ethernet port 2018-03-13
1938327.1 Installing Solaris Via Install Server or Jumpstart Server Over VLAN Fails With "Connection timed out" 2018-03-06
1934733.1 "capi_get_sensors() failed, status = -1" error when running commands on the Service Processor 2017-10-05
1924599.1 I/O error : failed to load external entity "/var/runtime/conf/frud_config.xml" 2017-12-15
1909686.1 LDAP/SSL Groups Not Recognized Properly By ILOM 2017-04-20
1904115.1 System fails to boot due to FATAL: /packages/deblocker: Last Trap: Non-Resumable Error 2017-05-01
1671764.1 Replacement disk managed by LSI not recognised by OS 2018-02-26
1669799.1 T5xx0: DIMM service LED remains lit after DIMM replacement 2017-10-05
1642386.1 T5120/T5220/T5140/T5240 and Netras - System may not power on or report many errors on both power supplies 2017-05-01
1637953.1 T5x20/T5x40 Server: poweron and resetsc fails: Flash in progress 2018-05-17
1637803.1 Solaris 10 T2 series servers without FW 7.4.4.f or later can hang in shutdown due to a stuck fmd thread 2014-03-24
1632323.1 "Hot removal of HDDx" or "/HDDx/PRSNT :Device Absent" appears upon poweron or resetting SP with System Firmware 7.3.0 or later 2017-07-12
1631469.1 T5120/T5220/T5140/T5240/Netra T5220/Netra T5440 won't power on due to FATAL: Polling POK Status Time Out problem 2017-05-01
1627528.1 T-Series servers with LSI106x(e) (mpt driver) / LSI2x08 (mpt_sas driver) controllers reports "Command Timeout" for all internal disks (HDD/SSD) Caused by mpt/mpt_sas driver bug 2018-03-06
1623583.1 T5xxx: Wrong DIMM failed by system, poweron hangs and loops 2018-05-17
1620275.1 Servicetag service not working 2017-10-05
1616612.1 Firmware update fails with sysfwdownload: download failure - status = 2 2017-05-18
1609319.1 T5120/T5140/T5220/T5240/T5440, Service Processor network management port looks failed due to link speed negotiation failure with connected Gigabit Ethernet switch 2018-05-17
1603789.1 Disk under LSI Hardware Raid (HWRaid) shows as N/A instead of a target number 2018-01-31
1598815.1 Service Processor (ILOM ) reboots continuously reporting IO errors on T5x20 2017-06-06
1580033.1 SP Resets on T5xx0, T3, T4, T5 and M5 Systems May Overwrite a User-Land Solaris Memory Page Causing In-Memory Corruption 2018-01-22
1573754.1 Sun SPARC T5120/T5220 reports faulty DIMMs on non existent or DIMM wrong slot 2017-09-29
1570590.1 SC hangs due to sccd daemon shutdown on T5x20/T5x40 Systems 2017-10-05
1561282.1 Troubleshooting Power Supply Issues on the T5xx0 (Netra included) platform 2017-04-26
1546734.1 Fan's State Is Shown As "Warning" (T5220) while prtdiag show no issue with the fans 2017-04-06
1534963.1 How to verify a bad disk in a cougar controlled Raid 5 array 2017-05-01
1531113.1 T-Series Servers: Solaris messages files filled with SC Alert: Audit events (Open, Close, Activate Session) 2017-10-05
1525190.1 Unable To Exceed 2 TB Limit On, SAS RAID HBA (SGXPCIESAS-R-INT-Z, aka Cougar) Logicaldrive 2017-10-06
1503161.1 Overtemp conditions for the Internal 8-port SAS RAID HBA (Cougar) in T5x20 and T5x40 2017-10-05
1494101.1 "Unable To Determine Platform Id" error in ALOM on T5120/T5220 & T5140/T5240 systems 2018-01-08
1490986.1 Multiple Fans Reported as Failed on T5220 & T5240 2018-04-25
1013102.1 PSH: Diagnosis Issue for T5120 and T5220 (SUN4V-8000-E2) 2018-01-04
  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
 Feedback