Problem Document
|
Synopsis
|
Last Modified Date
|
2368354.1 |
"Could not chdir to home directory : No such file or directory" in System firmware revision 7.4.10.a and 7.4.11 |
2018-03-02
|
2179850.1 |
Solaris Scsi Error - Sense Key: Aborted_Command - ASC: 0x44 (internal target failure), ASCQ: 0x0, FRU: 0x0 |
2018-03-07
|
2161328.1 |
ILOM BUI reports "Invalid session" after Firmware upgrade |
2017-12-07
|
2153885.1 |
Error during POST on T5220 Server: /SYS/MB/CMP0/NIU0 or/and NIU1 Forced fail (POST) |
2018-05-17
|
2135699.1 |
Cannot Log In To Service Processor (SP) On T3/T4/T5, T5x20, T5x40 Servers: Too many users are logged in |
2018-03-06
|
2126841.1 |
Oracle Hardware Management Pack's (OHMP) fwupdate command fails to install older disk firmware patches. |
2017-12-14
|
2112377.1 |
SunFire T5x0 : ILOM serial redirection fails: Certificates does not conform to algoritm |
2018-02-06
|
2108027.1 |
Solaris 11 systems showing a different Serial Number when activating ASR |
2016-02-23
|
2094200.1 |
T5120, T5220, T5140, T5240: Server powered itself off and refuses to power on due to "Chassis cover removed." |
2018-03-06
|
2070764.1 |
300GB, 600GB, 900GB, and 1.2 TB Disk Firmware Upgrade to Address Unrecoverable Read Errors in SPARC Platforms. |
2017-07-17
|
2022566.1 |
After creating a patched Alternate Boot Environment (ABE) via Live Upgrade, attempts to boot off ABE hang |
2015-06-19
|
1988705.1 |
Does Solaris scadm ALOM control utility exist on T1000/T2000/T5120/T5220/T5140/T5240 Servers? |
2018-05-17
|
1951504.1 |
DAT-72 - ASC: 0x0 ASCQ: 0x2 : Volume_Overflow, End-of-Media Detected, End of Partition/Medium Detected |
2017-08-16
|
1950178.1 |
T5120/T5220/T5140/T5240 and Netras System Shuts Down Due to Sensor Errors on /T_TCORE and /T_BCORE |
2017-05-01
|
1944663.1 |
T5xx0-T8 Servers: Service Processor Network connectivity lost without auto negotiation on Ethernet port |
2018-03-13
|
1938327.1 |
Installing Solaris Via Install Server or Jumpstart Server Over VLAN Fails With "Connection timed out" |
2018-03-06
|
1934733.1 |
"capi_get_sensors() failed, status = -1" error when running commands on the Service Processor |
2017-10-05
|
1924599.1 |
I/O error : failed to load external entity "/var/runtime/conf/frud_config.xml" |
2017-12-15
|
1909686.1 |
LDAP/SSL Groups Not Recognized Properly By ILOM |
2017-04-20
|
1904115.1 |
System fails to boot due to FATAL: /packages/deblocker: Last Trap: Non-Resumable Error |
2017-05-01
|
1671764.1 |
Replacement disk managed by LSI not recognised by OS |
2018-02-26
|
1669799.1 |
T5xx0: DIMM service LED remains lit after DIMM replacement |
2017-10-05
|
1642386.1 |
T5120/T5220/T5140/T5240 and Netras - System may not power on or report many errors on both power supplies |
2017-05-01
|
1637953.1 |
T5x20/T5x40 Server: poweron and resetsc fails: Flash in progress |
2018-05-17
|
1637803.1 |
Solaris 10 T2 series servers without FW 7.4.4.f or later can hang in shutdown due to a stuck fmd thread |
2014-03-24
|
1632323.1 |
"Hot removal of HDDx" or "/HDDx/PRSNT :Device Absent" appears upon poweron or resetting SP with System Firmware 7.3.0 or later |
2017-07-12
|
1631469.1 |
T5120/T5220/T5140/T5240/Netra T5220/Netra T5440 won't power on due to FATAL: Polling POK Status Time Out problem |
2017-05-01
|
1627528.1 |
T-Series servers with LSI106x(e) (mpt driver) / LSI2x08 (mpt_sas driver) controllers reports "Command Timeout" for all internal disks (HDD/SSD) Caused by mpt/mpt_sas driver bug |
2018-03-06
|
1623583.1 |
T5xxx: Wrong DIMM failed by system, poweron hangs and loops |
2018-05-17
|
1620275.1 |
Servicetag service not working |
2017-10-05
|
1616612.1 |
Firmware update fails with sysfwdownload: download failure - status = 2 |
2017-05-18
|
1609319.1 |
T5120/T5140/T5220/T5240/T5440, Service Processor network management port looks failed due to link speed negotiation failure with connected Gigabit Ethernet switch |
2018-05-17
|
1603789.1 |
Disk under LSI Hardware Raid (HWRaid) shows as N/A instead of a target number |
2018-01-31
|
1598815.1 |
Service Processor (ILOM ) reboots continuously reporting IO errors on T5x20 |
2017-06-06
|
1580033.1 |
SP Resets on T5xx0, T3, T4, T5 and M5 Systems May Overwrite a User-Land Solaris Memory Page Causing In-Memory Corruption |
2018-01-22
|
1573754.1 |
Sun SPARC T5120/T5220 reports faulty DIMMs on non existent or DIMM wrong slot |
2017-09-29
|
1570590.1 |
SC hangs due to sccd daemon shutdown on T5x20/T5x40 Systems |
2017-10-05
|
1561282.1 |
Troubleshooting Power Supply Issues on the T5xx0 (Netra included) platform |
2017-04-26
|
1546734.1 |
Fan's State Is Shown As "Warning" (T5220) while prtdiag show no issue with the fans |
2017-04-06
|
1534963.1 |
How to verify a bad disk in a cougar controlled Raid 5 array |
2017-05-01
|
1531113.1 |
T-Series Servers: Solaris messages files filled with SC Alert: Audit events (Open, Close, Activate Session) |
2017-10-05
|
1525190.1 |
Unable To Exceed 2 TB Limit On, SAS RAID HBA (SGXPCIESAS-R-INT-Z, aka Cougar) Logicaldrive |
2017-10-06
|
1503161.1 |
Overtemp conditions for the Internal 8-port SAS RAID HBA (Cougar) in T5x20 and T5x40 |
2017-10-05
|
1494101.1 |
"Unable To Determine Platform Id" error in ALOM on T5120/T5220 & T5140/T5240 systems |
2018-01-08
|
1490986.1 |
Multiple Fans Reported as Failed on T5220 & T5240 |
2018-04-25
|
1013102.1 |
PSH: Diagnosis Issue for T5120 and T5220 (SUN4V-8000-E2) |
2018-01-04
|