Solution Type  Problem Resolution Sure

Solution  1570590.1 :   SC hangs due to sccd daemon shutdown on T5x20/T5x40 Systems  


Related Items
  • Sun SPARC Enterprise T5240 Server
  •  
  • Sun Netra T5220 Server
  •  
  • Sun SPARC Enterprise T5220 Server
  •  
  • Sun SPARC Enterprise T5120 Server
  •  
  • Sun SPARC Enterprise T5440 Server
  •  
  • Sun SPARC Enterprise T5140 Server
  •  
  • Sun Netra T5440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5xx0
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-7539981261>

Applies to:

Sun SPARC Enterprise T5120 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5140 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5220 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5240 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5440 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

ssh <sc-hostname>
Password:

Waiting for daemons to initialize...

Timed out waiting for daemons to start
sccd daemon has shutdown

Sun(TM) Integrated Lights Out Manager

Version 3.0.6.1.d r48331

Copyright 2009 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.

->

-------
Sun System Firmware 7.2.4.e 2009/09/21 09:50

 

Cause

The most likely root cause is: system firmware BUG 6856163 After set defaults without LAN cable to NET MGT, sccd daemon shutdown
 

Solution

1. Power cycle the server with removing the power cords for at least 2 minutes

2. Update the firmware - ideally to the most recent version
    see: Firmware Downloads and Release History for Sun Systems  

3. If the hard reset or updating the firmware has not resolved the issue, this may be an actual ILOM problem. Please open a ticket with Oracle Support to evaluate further action.