![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1570590.1 : SC hangs due to sccd daemon shutdown on T5x20/T5x40 Systems
In this Document
Created from <SR 3-7539981261> Applies to:Sun SPARC Enterprise T5120 Server - Version All Versions to All Versions [Release All Releases]Sun SPARC Enterprise T5140 Server - Version All Versions to All Versions [Release All Releases] Sun SPARC Enterprise T5220 Server - Version All Versions to All Versions [Release All Releases] Sun SPARC Enterprise T5240 Server - Version All Versions to All Versions [Release All Releases] Sun SPARC Enterprise T5440 Server - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. Symptoms ssh <sc-hostname>
CauseThe most likely root cause is: system firmware BUG 6856163 After set defaults without LAN cable to NET MGT, sccd daemon shutdown Solution1. Power cycle the server with removing the power cords for at least 2 minutes 3. If the hard reset or updating the firmware has not resolved the issue, this may be an actual ILOM problem. Please open a ticket with Oracle Support to evaluate further action. Attachments This solution has no attachment |
||||||||||||||||
|