![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1623583.1 : T5xxx: Wrong DIMM failed by system, poweron hangs and loops
Chassis | major: Sep 27 15:16:07 ERROR: could not find key dimmc Chassis | major: Nov 20 14:03:58 ERROR: could not find key dimma In this Document
Applies to:Sun SPARC Enterprise T5220 Server - Version All Versions and laterInformation in this document applies to any platform. SymptomsT5220 fails to poweron and loops with error messages
Example 1 sc> poweron -c
Enter #. to return to ALOM. Chassis | major: Host has been powered on Chassis | major: Nov 20 15:26:08 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Fault | critical: SP detected fault at time Tue Nov 20 15:26:09 2012. /SYS/MB/CMP0/BR1/CH0/D1 Forced fail (DRAM init) Chassis | major: Nov 20 15:26:35 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 15:27:01 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 15:27:28 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 15:27:54 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 15:28:20 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 15:28:45 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 15:29:12 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 15:29:37 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 15:30:05 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 15:30:30 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 15:30:57 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 15:31:22 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 15:31:49 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 15:32:16 ERROR: MB/CMP0/BR1/CH1/D0 initialization failed: DRAM init, disabled / The system will then loop with a spinning chevron outputting the above error and poweron does not complete. In above example there are no D1 DIMMs installed and the bad DIMM is located in SYS/MB/CMP0/BR1/CH1/D0.
Example 2 sc> poweron -c
Enter #. to return to ALOM. Chassis | major: Host has been powered on Chassis | major: Nov 20 14:03:58 ERROR: MB/CMP0/BR2/CH1/D0 initialization failed: DRAM init, disabled Chassis | major: Nov 20 14:03:58 ERROR: could not find key dimma / The system will then loop with a spinning chevron outputting the above error and poweron does not complete. In above example notice the event "could not find key dimma", other events may report "could not find key dimmc" and the bad DIMM is located in /SYS/MB/CMP0/BR2/CH1/D0. CauseIn example 1, the root cause is Bug 16738856: Wrong DIMM failed by POST and system fails to poweron In example 2, the root cause is Bug 17593160: Faulty DIMM not disabled and does not allow poweron
SolutionExample 1 is resolved in Firmware 7.4.8 (147307-11: FIRMWARE: SPARC Enterprise T5120+T5220 - Sun System Firmware 7.4.8)
More details about the fix are: - Bug 16738856: WRONG DIMM FAILED BY POST AND SYSTEM FAILS TO POWERON
Fixed in Product Version: 1.10.3 (147307-10: FIRMWARE: SPARC Enterprise T5120+T5220 - Sun System Firmware 7.4.7) - Bug 17593160 : FAULTY DIMM NOT DISABLED AND DOES NOT ALLOW POWERON Fixed in Product Version: 1.10.3 (147307-10: FIRMWARE: SPARC Enterprise T5120+T5220 - Sun System Firmware 7.4.7) - Bug 18249666 : FIXES FOR BUGS 17593160 / 16738856 NOT WORKING IN FIRMWARE 7.4.7 Fixed in Product Version: 1.10.3 (147307-11: FIRMWARE: SPARC Enterprise T5120+T5220 - Sun System Firmware 7.4.8) - 147307-11: FIRMWARE: SPARC Enterprise T5120+T5220 - Sun System Firmware 7.4.8 (Aug/22/2014) 18249666 Fixes for bugs 17593160 / 16738856 not working in Firmware 7.4.7 and other affected systems are: - 147307-11:FIRMWARE: SPARC Enterprise T5120+T5220 - Sun System Firmware 7.4.8 (Aug/22/2014)
18249666 Fixes for bugs 17593160 / 16738856 not working in Firmware 7.4.7 - 147308-09:FIRMWARE: Sun Blade T6320+T6320-G2 Server Module - Sun System Firmware 7.4.8 (Aug/22/2014) 18249666 Fixes for bugs 17593160 / 16738856 not working in Firmware 7.4.7 - 147309-10:FIRMWARE: Netra T5220 - Sun System Firmware 7.4.8 (Aug/22/2014) 18249666 Fixes for bugs 17593160 / 16738856 not working in Firmware 7.4.7 - 147310-11:FIRMWARE: SPARC Enterprise T5140+T5240 - Sun System Firmware 7.4.8 (Aug/22/2014) 18249666 Fixes for bugs 17593160 / 16738856 not working in Firmware 7.4.7 - 147311-09:FIRMWARE: SPARC Enterprise T5440 - Sun System Firmware 7.4.8 (Aug/22/2014) 18249666 Fixes for bugs 17593160 / 16738856 not working in Firmware 7.4.7 - 147312-10:FIRMWARE: Sun Blade T6340 Server Module - Sun System Firmware 7.4.8 (Aug/22/2014) 18249666 Fixes for bugs 17593160 / 16738856 not working in Firmware 7.4.7 - 147313-11:FIRMWARE: Netra T5440 - Sun System Firmware 7.4.8 (Aug/22/2014) 18249666 Fixes for bugs 17593160 / 16738856 not working in Firmware 7.4.7 - 147314-10:FIRMWARE: Netra T6340 - Sun System Firmware 7.4.8 (Aug/22/2014) 18249666 Fixes for bugs 17593160 / 16738856 not working in Firmware 7.4.7 and keep in mind, that the issues described in below doc might be applicable too: How to recognize DIMMs faulting for sense transistor failure in Netra & commercial T5xx0, Tx000, V2xx, V44x, V125, U25, U45 servers & in the T6300, Netra CP3060, CP2500 blades (Doc ID 1533010.1)
and for the used DIMMs in CMT systems look at below doc: DIMMs used in CMT Products (Doc ID 1411086.1)
Attachments This solution has no attachment |
||||||||||||||||||
|