Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1642386.1
Update Date:2017-05-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  1642386.1 :   T5120/T5220/T5140/T5240 and Netras - System may not power on or report many errors on both power supplies  


Related Items
  • Sun Netra T5440 Server
  •  
  • Sun Fire X4140 Server
  •  
  • Sun SPARC Enterprise T5220 Server
  •  
  • Sun Netra T5220 Server
  •  
  • Sun SPARC Enterprise T5120 Server
  •  
  • Sun SPARC Enterprise T5240 Server
  •  
  • Sun SPARC Enterprise T5140 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5xx0
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-8689905931>

Applies to:

Sun SPARC Enterprise T5220 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5240 Server - Version Not Applicable to Not Applicable [Release NA]
Sun SPARC Enterprise T5140 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5120 Server - Version Not Applicable to Not Applicable [Release NA]
Sun Netra T5440 Server - Version Not Applicable to Not Applicable [Release NA]
Information in this document applies to any platform.

Symptoms

Server will not power on or it will power on but show PSU voltage errors in the ILOM logs (-> show /SP/logs/event/list or sc> showlogs -v).

 

Some of the errors seen:

50298  Wed Mar 19 12:55:52 2014  Chassis   Log       minor          Error getting OUTPUT current limit for PS1
50297  Wed Mar 19 12:55:52 2014  Chassis   Log       minor          Error getting OUTPUT current for PS1
50296  Wed Mar 19 12:55:52 2014  Chassis   Log       minor          Error getting OUTPUT voltage for PS1
50295  Wed Mar 19 12:55:52 2014  Chassis   Log       minor          Error getting INPUT current limit for PS1
50294  Wed Mar 19 12:55:52 2014  Chassis   Log       minor          Error getting INPUT current for PS1
50293  Wed Mar 19 12:55:52 2014  Chassis   Log       minor          Error getting INPUT voltage for PS1
50292  Wed Mar 19 12:55:52 2014  Chassis   Log       minor          Error getting warning data for PS1
50291  Wed Mar 19 12:55:51 2014  Chassis   Log       minor          Error getting shutdown data for PS1
50290  Wed Mar 19 12:55:51 2014  Chassis   Log       minor          Error getting status data for PS1
50289  Wed Mar 19 12:55:51 2014  Chassis   Log       minor          Error getting OUTPUT current limit for PS0
50288  Wed Mar 19 12:55:51 2014  Chassis   Log       minor          Error getting OUTPUT current for PS0
50287  Wed Mar 19 12:55:51 2014  Chassis   Log       minor          Error getting OUTPUT voltage for PS0
50286  Wed Mar 19 12:55:51 2014  Chassis   Log       minor          Error getting INPUT current limit for PS0
50285  Wed Mar 19 12:55:51 2014  Chassis   Log       minor          Error getting INPUT current for PS0
50284  Wed Mar 19 12:55:50 2014  Chassis   Log       minor          Error getting INPUT voltage for PS0
50283  Wed Mar 19 12:55:50 2014  Chassis   Log       minor          Error getting warning data for PS0
50282  Wed Mar 19 12:55:50 2014  Chassis   Log       minor          Error getting shutdown data for PS0
50281  Wed Mar 19 12:55:50 2014  Chassis   Log       minor          Error getting status data for PS0
50280  Wed Mar 19 12:55:03 2014  Chassis   Log       major          System poweron is disabled

And:

50258  Wed Mar 19 12:42:56 2014  Fault     Repair    minor          SP detected fault cleared at time Wed Mar 19 12:42:55 2014. Temperature fault at PS1 asserted
50257  Wed Mar 19 12:42:55 2014  Fault     Repair    minor          SP detected fault cleared at time Wed Mar 19 12:42:55 2014. Current fault at PS0 asserted
50256  Wed Mar 19 12:42:54 2014  Fault     Repair    minor          SP detected fault cleared at time Wed Mar 19 12:42:53 2014. Voltage fault at PS0 asserted
50255  Wed Mar 19 12:42:52 2014  Fault     Repair    minor          SP detected fault cleared at time Wed Mar 19 12:42:52 2014. Current fault at PS1 asserted
50254  Wed Mar 19 12:42:51 2014  Fault     Repair    minor          SP detected fault cleared at time Wed Mar 19 12:42:50 2014. Voltage fault at PS1 asserted
50253  Wed Mar 19 12:42:50 2014  Fault     Repair    minor          SP detected fault cleared at time Wed Mar 19 12:42:50 2014. Temperature fault at PS0 asserted
50252  Wed Mar 19 12:42:30 2014  IPMI      Log       minor          ID = 8eec : 03/19/2014 : 12:42:30 : Temperature : /PS1/VOLT_FAULT : State Deasserted
50251  Wed Mar 19 12:42:30 2014  IPMI      Log       minor          ID = 8eeb : 03/19/2014 : 12:42:30 : Current : /PS0/FAIL : State Deasserted
50250  Wed Mar 19 12:42:28 2014  IPMI      Log       minor          ID = 8eea : 03/19/2014 : 12:42:28 : Voltage : /PS0/DC_POK : State Deasserted
50249  Wed Mar 19 12:42:27 2014  IPMI      Log       minor          ID = 8ee9 : 03/19/2014 : 12:42:27 : Current : /PS1/AC_POK : State Deasserted
50248  Wed Mar 19 12:42:26 2014  IPMI      Log       minor          ID = 8ee8 : 03/19/2014 : 12:42:26 : Voltage : /PS1/DC_POK : State Deasserted
50247  Wed Mar 19 12:42:26 2014  IPMI      Log       minor          ID = 8ee7 : 03/19/2014 : 12:42:26 : Temperature : /PS0/VOLT_FAULT : State Deasserted
50246  Wed Mar 19 12:42:06 2014  Fault     Fault     critical       SP detected fault at time Wed Mar 19 12:42:06 2014. Current fault at PS0 asserted
50245  Wed Mar 19 12:42:04 2014  Fault     Fault     critical       SP detected fault at time Wed Mar 19 12:42:04 2014. Voltage fault at PS0 asserted
50244  Wed Mar 19 12:41:24 2014  Fault     Fault     critical       SP detected fault at time Wed Mar 19 12:41:24 2014. Temperature fault at PS0 asserted
50243  Wed Mar 19 12:41:04 2014  IPMI      Log       critical       ID = 8ee6 : 03/19/2014 : 12:41:04 : Temperature : /PS0/VOLT_FAULT : State Asserted
50242  Wed Mar 19 12:41:02 2014  IPMI      Log       critical       ID = 8ee5 : 03/19/2014 : 12:41:02 : Current : /PS0/FAIL : State Asserted
50241  Wed Mar 19 12:41:01 2014  IPMI      Log       critical       ID = 8ee4 : 03/19/2014 : 12:41:01 : Voltage : /PS0/DC_POK : State Asserted
50240  Wed Mar 19 12:40:57 2014  Fault     Fault     critical       SP detected fault at time Wed Mar 19 12:40:57 2014. Temperature fault at PS1 asserted
50239  Wed Mar 19 12:40:55 2014  Fault     Fault     critical       SP detected fault at time Wed Mar 19 12:40:55 2014. Current fault at PS1 asserted
50238  Wed Mar 19 12:40:53 2014  Fault     Fault     critical       SP detected fault at time Wed Mar 19 12:40:53 2014. Voltage fault at PS1 asserted
50237  Wed Mar 19 12:40:36 2014  IPMI      Log       critical       ID = 8ee3 : 03/19/2014 : 12:40:36 : Temperature : /PS1/VOLT_FAULT : State Asserted
50236  Wed Mar 19 12:40:34 2014  IPMI      Log       critical       ID = 8ee2 : 03/19/2014 : 12:40:34 : Current : /PS1/AC_POK : State Asserted
50235  Wed Mar 19 12:40:33 2014  IPMI      Log       critical       ID = 8ee1 : 03/19/2014 : 12:40:33 : Voltage : /PS1/DC_POK : State Asserted

You may also encounter backplane errors:

50321  Wed Mar 19 13:08:33 2014  IPMI      Log       minor          ID = 8f00 : 03/19/2014 : 13:08:32 : Entity Presence : /SASBP/PRSNT : Device Present
50320  Wed Mar 19 13:08:26 2014  IPMI      Log       minor          ID = 8eff : 03/19/2014 : 13:08:26 : Entity Presence : /SASBP/PRSNT : Device Absent
50316  Wed Mar 19 13:04:26 2014  IPMI      Log       minor          ID = 8efe : 03/19/2014 : 13:04:26 : Entity Presence : /SASBP/PRSNT : Device Present
50315  Wed Mar 19 13:04:15 2014  IPMI      Log       minor          ID = 8efd : 03/19/2014 : 13:04:15 : Entity Presence : /SASBP/PRSNT : Device Absent
50314  Wed Mar 19 13:03:57 2014  IPMI      Log       minor          ID = 8efc : 03/19/2014 : 13:03:57 : Entity Presence : /SASBP/PRSNT : Device Present
50313  Wed Mar 19 13:03:52 2014  IPMI      Log       minor          ID = 8efb : 03/19/2014 : 13:03:52 : Entity Presence : /SASBP/PRSNT : Device Absent
50312  Wed Mar 19 13:03:22 2014  IPMI      Log       minor          ID = 8efa : 03/19/2014 : 13:03:22 : Entity Presence : /SASBP/PRSNT : Device Present
50311  Wed Mar 19 13:03:04 2014  IPMI      Log       minor          ID = 8ef9 : 03/19/2014 : 13:03:03 : Entity Presence : /SASBP/PRSNT : Device Absent
50310  Wed Mar 19 13:02:02 2014  IPMI      Log       minor          ID = 8ef8 : 03/19/2014 : 13:02:02 : Entity Presence : /SASBP/PRSNT : Device Present
50302  Wed Mar 19 13:01:22 2014  IPMI      Log       minor          ID = 8ef7 : 03/19/2014 : 13:01:22 : Entity Presence : /SASBP/PRSNT : Device Absent
50301  Wed Mar 19 12:58:55 2014  IPMI      Log       minor          ID = 8ef6 : 03/19/2014 : 12:58:55 : Entity Presence : /SASBP/PRSNT : Device Present
50300  Wed Mar 19 12:58:39 2014  IPMI      Log       minor          ID = 8ef5 : 03/19/2014 : 12:58:39 : Entity Presence : /SASBP/PRSNT : Device Absent

Cause

This is most likely a hardware issue. Could be a problem with the power distribution board.

Solution

 Please perform the following:

1) Make sure your firmware is up to date to the latest. Firmware can fix many false positive problems and also sensor thresholds.

2) Make sure both power supplies are seated properly and that they are receiving ample power from the cords; make sure the power cables and outlet are working properly as intended

 

If the above doesn't resolve the issue, please open an SR with Oracle Support

 

The above issue was fixed by replacing the PDB. The customer also managed to open the box and verify that the Ribbon Cable is seated properly, but not all customers may be willing to check that themselves.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback