T5120/T5220/T5140/T5240 and Netras - System may not power on or report many errors on both power supplies
Related Items |
- Sun Netra T5440 Server
- Sun Fire X4140 Server
- Sun SPARC Enterprise T5220 Server
- Sun Netra T5220 Server
- Sun SPARC Enterprise T5120 Server
- Sun SPARC Enterprise T5240 Server
- Sun SPARC Enterprise T5140 Server
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5xx0
|
In this Document
Created from <SR 3-8689905931>
Applies to:
Sun SPARC Enterprise T5220 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5240 Server - Version Not Applicable to Not Applicable [Release NA]
Sun SPARC Enterprise T5140 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5120 Server - Version Not Applicable to Not Applicable [Release NA]
Sun Netra T5440 Server - Version Not Applicable to Not Applicable [Release NA]
Information in this document applies to any platform.
Symptoms
Server will not power on or it will power on but show PSU voltage errors in the ILOM logs (-> show /SP/logs/event/list or sc> showlogs -v).
Some of the errors seen:
50298 Wed Mar 19 12:55:52 2014 Chassis Log minor Error getting OUTPUT current limit for PS1
50297 Wed Mar 19 12:55:52 2014 Chassis Log minor Error getting OUTPUT current for PS1
50296 Wed Mar 19 12:55:52 2014 Chassis Log minor Error getting OUTPUT voltage for PS1
50295 Wed Mar 19 12:55:52 2014 Chassis Log minor Error getting INPUT current limit for PS1
50294 Wed Mar 19 12:55:52 2014 Chassis Log minor Error getting INPUT current for PS1
50293 Wed Mar 19 12:55:52 2014 Chassis Log minor Error getting INPUT voltage for PS1
50292 Wed Mar 19 12:55:52 2014 Chassis Log minor Error getting warning data for PS1
50291 Wed Mar 19 12:55:51 2014 Chassis Log minor Error getting shutdown data for PS1
50290 Wed Mar 19 12:55:51 2014 Chassis Log minor Error getting status data for PS1
50289 Wed Mar 19 12:55:51 2014 Chassis Log minor Error getting OUTPUT current limit for PS0
50288 Wed Mar 19 12:55:51 2014 Chassis Log minor Error getting OUTPUT current for PS0
50287 Wed Mar 19 12:55:51 2014 Chassis Log minor Error getting OUTPUT voltage for PS0
50286 Wed Mar 19 12:55:51 2014 Chassis Log minor Error getting INPUT current limit for PS0
50285 Wed Mar 19 12:55:51 2014 Chassis Log minor Error getting INPUT current for PS0
50284 Wed Mar 19 12:55:50 2014 Chassis Log minor Error getting INPUT voltage for PS0
50283 Wed Mar 19 12:55:50 2014 Chassis Log minor Error getting warning data for PS0
50282 Wed Mar 19 12:55:50 2014 Chassis Log minor Error getting shutdown data for PS0
50281 Wed Mar 19 12:55:50 2014 Chassis Log minor Error getting status data for PS0
50280 Wed Mar 19 12:55:03 2014 Chassis Log major System poweron is disabled
And:
50258 Wed Mar 19 12:42:56 2014 Fault Repair minor SP detected fault cleared at time Wed Mar 19 12:42:55 2014. Temperature fault at PS1 asserted
50257 Wed Mar 19 12:42:55 2014 Fault Repair minor SP detected fault cleared at time Wed Mar 19 12:42:55 2014. Current fault at PS0 asserted
50256 Wed Mar 19 12:42:54 2014 Fault Repair minor SP detected fault cleared at time Wed Mar 19 12:42:53 2014. Voltage fault at PS0 asserted
50255 Wed Mar 19 12:42:52 2014 Fault Repair minor SP detected fault cleared at time Wed Mar 19 12:42:52 2014. Current fault at PS1 asserted
50254 Wed Mar 19 12:42:51 2014 Fault Repair minor SP detected fault cleared at time Wed Mar 19 12:42:50 2014. Voltage fault at PS1 asserted
50253 Wed Mar 19 12:42:50 2014 Fault Repair minor SP detected fault cleared at time Wed Mar 19 12:42:50 2014. Temperature fault at PS0 asserted
50252 Wed Mar 19 12:42:30 2014 IPMI Log minor ID = 8eec : 03/19/2014 : 12:42:30 : Temperature : /PS1/VOLT_FAULT : State Deasserted
50251 Wed Mar 19 12:42:30 2014 IPMI Log minor ID = 8eeb : 03/19/2014 : 12:42:30 : Current : /PS0/FAIL : State Deasserted
50250 Wed Mar 19 12:42:28 2014 IPMI Log minor ID = 8eea : 03/19/2014 : 12:42:28 : Voltage : /PS0/DC_POK : State Deasserted
50249 Wed Mar 19 12:42:27 2014 IPMI Log minor ID = 8ee9 : 03/19/2014 : 12:42:27 : Current : /PS1/AC_POK : State Deasserted
50248 Wed Mar 19 12:42:26 2014 IPMI Log minor ID = 8ee8 : 03/19/2014 : 12:42:26 : Voltage : /PS1/DC_POK : State Deasserted
50247 Wed Mar 19 12:42:26 2014 IPMI Log minor ID = 8ee7 : 03/19/2014 : 12:42:26 : Temperature : /PS0/VOLT_FAULT : State Deasserted
50246 Wed Mar 19 12:42:06 2014 Fault Fault critical SP detected fault at time Wed Mar 19 12:42:06 2014. Current fault at PS0 asserted
50245 Wed Mar 19 12:42:04 2014 Fault Fault critical SP detected fault at time Wed Mar 19 12:42:04 2014. Voltage fault at PS0 asserted
50244 Wed Mar 19 12:41:24 2014 Fault Fault critical SP detected fault at time Wed Mar 19 12:41:24 2014. Temperature fault at PS0 asserted
50243 Wed Mar 19 12:41:04 2014 IPMI Log critical ID = 8ee6 : 03/19/2014 : 12:41:04 : Temperature : /PS0/VOLT_FAULT : State Asserted
50242 Wed Mar 19 12:41:02 2014 IPMI Log critical ID = 8ee5 : 03/19/2014 : 12:41:02 : Current : /PS0/FAIL : State Asserted
50241 Wed Mar 19 12:41:01 2014 IPMI Log critical ID = 8ee4 : 03/19/2014 : 12:41:01 : Voltage : /PS0/DC_POK : State Asserted
50240 Wed Mar 19 12:40:57 2014 Fault Fault critical SP detected fault at time Wed Mar 19 12:40:57 2014. Temperature fault at PS1 asserted
50239 Wed Mar 19 12:40:55 2014 Fault Fault critical SP detected fault at time Wed Mar 19 12:40:55 2014. Current fault at PS1 asserted
50238 Wed Mar 19 12:40:53 2014 Fault Fault critical SP detected fault at time Wed Mar 19 12:40:53 2014. Voltage fault at PS1 asserted
50237 Wed Mar 19 12:40:36 2014 IPMI Log critical ID = 8ee3 : 03/19/2014 : 12:40:36 : Temperature : /PS1/VOLT_FAULT : State Asserted
50236 Wed Mar 19 12:40:34 2014 IPMI Log critical ID = 8ee2 : 03/19/2014 : 12:40:34 : Current : /PS1/AC_POK : State Asserted
50235 Wed Mar 19 12:40:33 2014 IPMI Log critical ID = 8ee1 : 03/19/2014 : 12:40:33 : Voltage : /PS1/DC_POK : State Asserted
You may also encounter backplane errors:
50321 Wed Mar 19 13:08:33 2014 IPMI Log minor ID = 8f00 : 03/19/2014 : 13:08:32 : Entity Presence : /SASBP/PRSNT : Device Present
50320 Wed Mar 19 13:08:26 2014 IPMI Log minor ID = 8eff : 03/19/2014 : 13:08:26 : Entity Presence : /SASBP/PRSNT : Device Absent
50316 Wed Mar 19 13:04:26 2014 IPMI Log minor ID = 8efe : 03/19/2014 : 13:04:26 : Entity Presence : /SASBP/PRSNT : Device Present
50315 Wed Mar 19 13:04:15 2014 IPMI Log minor ID = 8efd : 03/19/2014 : 13:04:15 : Entity Presence : /SASBP/PRSNT : Device Absent
50314 Wed Mar 19 13:03:57 2014 IPMI Log minor ID = 8efc : 03/19/2014 : 13:03:57 : Entity Presence : /SASBP/PRSNT : Device Present
50313 Wed Mar 19 13:03:52 2014 IPMI Log minor ID = 8efb : 03/19/2014 : 13:03:52 : Entity Presence : /SASBP/PRSNT : Device Absent
50312 Wed Mar 19 13:03:22 2014 IPMI Log minor ID = 8efa : 03/19/2014 : 13:03:22 : Entity Presence : /SASBP/PRSNT : Device Present
50311 Wed Mar 19 13:03:04 2014 IPMI Log minor ID = 8ef9 : 03/19/2014 : 13:03:03 : Entity Presence : /SASBP/PRSNT : Device Absent
50310 Wed Mar 19 13:02:02 2014 IPMI Log minor ID = 8ef8 : 03/19/2014 : 13:02:02 : Entity Presence : /SASBP/PRSNT : Device Present
50302 Wed Mar 19 13:01:22 2014 IPMI Log minor ID = 8ef7 : 03/19/2014 : 13:01:22 : Entity Presence : /SASBP/PRSNT : Device Absent
50301 Wed Mar 19 12:58:55 2014 IPMI Log minor ID = 8ef6 : 03/19/2014 : 12:58:55 : Entity Presence : /SASBP/PRSNT : Device Present
50300 Wed Mar 19 12:58:39 2014 IPMI Log minor ID = 8ef5 : 03/19/2014 : 12:58:39 : Entity Presence : /SASBP/PRSNT : Device Absent
Cause
This is most likely a hardware issue. Could be a problem with the power distribution board.
Solution
Please perform the following:
1) Make sure your firmware is up to date to the latest. Firmware can fix many false positive problems and also sensor thresholds.
2) Make sure both power supplies are seated properly and that they are receiving ample power from the cords; make sure the power cables and outlet are working properly as intended
If the above doesn't resolve the issue, please open an SR with Oracle Support
The above issue was fixed by replacing the PDB. The customer also managed to open the box and verify that the Ribbon Cable is seated properly, but not all customers may be willing to check that themselves.