![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1637803.1 : Solaris 10 T2 series servers without FW 7.4.4.f or later can hang in shutdown due to a stuck fmd thread
In this Document
Created from <SR 3-8672683094> Applies to:Sun Netra T5220 Server - Version All Versions and laterSolaris SPARC Operating System - Version 10 3/05 and later Sun SPARC Enterprise T5220 Server - Version All Versions and later Sun SPARC Enterprise T5120 Server - Version All Versions and later Sun SPARC Enterprise T5140 Server - Version All Versions and later Oracle Solaris on SPARC (64-bit) SymptomsSolaris 10 T2 servers without FW 7.4.4.f or later can hang during shutdown due to a stuck fmd thread. > ::ptree
00000000018886c0 sched 0000060010aa6c28 fsflush 0000060010aa7848 pageout 0000060010aa8468 init 000006001ec0e470 automountd 000003005568a478 automountd 000003007404cc68 rpcbind 0000030055674c40 in.mpathd 0000030055675860 kcfd 0000060010aa6008 syseventd 00000300608f90a8 devfsadm 000006001ec0d850 svc.configd 000006001ec0f090 svc.startd 0000030075a88058 fmd 0000030075d78068 fmd <<<<< > 30075d78068::ps -t S PID PPID PGID SID UID FLAGS ADDR NAME R 624 595 624 624 0 0x42000000 0000030075d78068 fmd T 0x300605a8b60 <TS_SLEEP> <<<<<< T 0x30073af2740 <TS_SLEEP> > 0x300605a8b60::findstack stack pointer for thread 300605a8b60: 2a10205af51 [ 000002a10205af51 cv_wait_sig+0x114() ] 000002a10205b001 ds_pri_ioctl+0xa0() 000002a10205b0e1 fop_ioctl+0x20() 000002a10205b191 ioctl+0x184() 000002a10205b2e1 syscall_trap32+0xcc() This issue affects all T2 servers without FW 7.4.4.f or later. CauseBug 15705246 - SUNBT7031127 Cluster node hung during shutdown as fmd thread stuck in ds_pri_ope SolutionThis issue is fixed by System Firmware 7.4.4.f or later in the following patches 147307-07 or later for SPARC Enterprise T5120+T5220
147308-05 or later for Sun Blade T6320+T6320-G2 Server Module 147309-06 or later for Netra T5220 147310-07 or later for SPARC Enterprise T5140+T5240 147311-05 or later for SPARC Enterprise T5440 147312-06 or later for Sun Blade T6340 Server Module 147313-06 or later for Netra T5440 147314-06 or later for Netra T6340
References<BUG:15705246> - SUNBT7031127 CLUSTER NODE HUNG DURING SHUTDOWN AS FMD THREAD STUCK IN DS_PRI_OPEAttachments This solution has no attachment |
||||||||||||||||||
|