Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1632323.1
Update Date:2017-07-12
Keywords:

Solution Type  Problem Resolution Sure

Solution  1632323.1 :   "Hot removal of HDDx" or "/HDDx/PRSNT :Device Absent" appears upon poweron or resetting SP with System Firmware 7.3.0 or later  


Related Items
  • Sun SPARC Enterprise T5240 Server
  •  
  • Sun SPARC Enterprise T5220 Server
  •  
  • Sun Netra T5220 Server
  •  
  • Sun SPARC Enterprise T5120 Server
  •  
  • Sun Blade T6320 Server Module
  •  
  • Sun SPARC Enterprise T5140 Server
  •  
  • Sun SPARC Enterprise T5440 Server
  •  
  • Sun Blade T6340 Server Module
  •  
  • Sun Netra T5440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5xx0
  •  




Created from <SR 3-8402967351>

Applies to:

Sun SPARC Enterprise T5120 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5220 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5140 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5240 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T5440 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Affected systems are:
- Sun SPARC Enterprise T5120 Server
- Sun SPARC Enterprise T5220 Server
- Sun SPARC Enterprise T5140 Server
- Sun SPARC Enterprise T5240 Server
- Sun SPARC Enterprise T5440 Server
- Sun Blade T6320 Server Module
- Sun Blade T6340 Server Module
- Sun Netra T5220 Server
- Sun Netra T5440 Server
- Sun Netra T6340 Server Module


When this issue occur, you will see "Hot removal of HDDx" or "/HDDx/PRSNT :Device Absent" events in the output of the command "showlogs -v" on the system controller.

These messages occur:
- on any HDD, it doesn't matter if a HDD is installed or not in the HDD slot
- upon every poweron of the system
- during a reset of the system controller

and hereby an example:

<timestamp>: Chassis |major   : "Host has been powered on"
<timestamp>: Chassis |major   : "Hot removal of HDD2"
<timestamp>: Chassis |major   : "Hot removal of HDD3"
<timestamp>: Chassis |major   : "Host is running"
<timestamp>: Chassis |major   : "System shutdown has been requested via power button."
<timestamp>: Chassis |major   : "System power on has been requested via power button."
<timestamp>: Chassis |major   : "Host has been powered on"
<timestamp>: Chassis |major   : "Hot removal of HDD3"
<timestamp>: Chassis |major   : "Hot removal of HDD2"
<timestamp>: Chassis |major   : "Host is running"
<timestamp>: Chassis |critical: "Host has been powered off"
<timestamp>: Chassis |major   : "Host has been powered on"
<timestamp>: Chassis |major   : "Hot removal of HDD2"
<timestamp>: Chassis |major   : "Hot removal of HDD3"
<timestamp>: Chassis |major   : "Host is running"


The Disk Status in the output of the command "showenvironment" on the system controller doesn't show any faults:

System Disks:
-----------------------------------------------
Disk      Status           Service        OK2RM
-----------------------------------------------
/SYS/HDD0  OK               OFF           OFF    
/SYS/HDD1  OK               OFF           OFF    
/SYS/HDD2  NOT PRESENT      OFF           OFF    
/SYS/HDD3  NOT PRESENT      OFF           OFF     


This issue can occur with System Firmware 7.3.0 or later.

Cause

It has been sporadically observed, that versions of System Firmware below 7.4.7 might incorrectly handle the signals that they receive from the hardware components resulting in false "Removal" or "Absence" Events.

Bug 15691318 : SUNBT7011898 HOT REMOVAL OF HDDX APPEARS WHEN POWERON MESSAGES WITH 7.3.0 FW ON T5x20 SYSTEMS
Bug 17731184 : PORT FIX FOR 15691318 TO NETRA T5220

Solution

This issue has been resolved in System Firmware 7.4.7 or later, which can be downloaded via the following links:

- Sun SPARC Enterprise T5120 Server
- Sun SPARC Enterprise T5220 Server
- Sun SPARC Enterprise T5140 Server
- Sun SPARC Enterprise T5240 Server
- Sun SPARC Enterprise T5440 Server
- Sun Blade T6320 Server Module
- Sun Blade T6340 Server Module
- Sun Netra T5220 Server
- Sun Netra T5440 Server
- Sun Netra T6340 Server Module

If you should see these messages: "Hot removal of HDDx" or "/HDDx/PRSNT :Device Absent" with System Firmware 7.4.7 or later, please open a Service Request at Oracle Support.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback