Asset ID: |
1-72-2022566.1 |
Update Date: | 2015-06-19 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2022566.1
:
After creating a patched Alternate Boot Environment (ABE) via Live Upgrade, attempts to boot off ABE hang
Related Items |
- Sun SPARC Enterprise T5220 Server
- Solaris Operating System
|
Related Categories |
- PLA-Support>Sun Systems>DISK>HBA>SN-DK: FC HBA
|
In this Document
Created from <SR 3-10444017801>
Applies to:
Sun SPARC Enterprise T5220 Server - Version All Versions and later
Solaris SPARC Operating System - Version 8.0 to 11.2 [Release 8.0 to 11.0]
Information in this document applies to any platform.
Symptoms
Issue
- after creating a patched Alternate Boot Environment (ABE) via Live Upgrade
- attempts to boot off ABE hang
- no issue booting off original Boot Environment
Cause
Server firmware downrev.
HOST TYPE : SPARC Enterprise T5220
HOST OS : Solaris 10 10/08 s10s_u6wos_07b SPARC
Sun System Firmware 7.0.9.c 2008/01/14 22:51
OBP 4.27.10 2007/12/07 10:45
Solution
upgrade system firmware
Patch 147307-12 FIRMWARE: SPARC Enterprise T5120+T5220 - Sun System Firmware 7.4.8.a
References
<NOTE:2003819.1> - On Solaris 10 U11 or Later, the Boot Process Hangs at Recognizing the Emulex FC Cards Installed
Attachments