Problem Document
|
Synopsis
|
Last Modified Date
|
2368354.1 |
"Could not chdir to home directory : No such file or directory" in System firmware revision 7.4.10.a and 7.4.11 |
2018-03-02
|
2294504.1 |
Disk Serial Numbers Not Shown in "iostat -En" |
2017-08-07
|
2170826.1 |
T5xx0 + T6320/T6340 servers: The Service Processor's (SP) root user must keep the ILOM shell otherwise the SP snapshot tool fails to collect data. |
2017-06-06
|
2112377.1 |
SunFire T5x0 : ILOM serial redirection fails: Certificates does not conform to algoritm |
2018-02-06
|
2108027.1 |
Solaris 11 systems showing a different Serial Number when activating ASR |
2016-02-23
|
2094200.1 |
T5120, T5220, T5140, T5240: Server powered itself off and refuses to power on due to "Chassis cover removed." |
2018-03-06
|
2070764.1 |
300GB, 600GB, 900GB, and 1.2 TB Disk Firmware Upgrade to Address Unrecoverable Read Errors in SPARC Platforms. |
2017-07-17
|
1988705.1 |
Does Solaris scadm ALOM control utility exist on T1000/T2000/T5120/T5220/T5140/T5240 Servers? |
2018-05-17
|
1987972.1 |
A Production T5120 Server Is Down Frequently Due To The Sensing Of Critical Voltage |
2017-04-07
|
1944663.1 |
T5xx0-T8 Servers: Service Processor Network connectivity lost without auto negotiation on Ethernet port |
2018-03-13
|
1938327.1 |
Installing Solaris Via Install Server or Jumpstart Server Over VLAN Fails With "Connection timed out" |
2018-03-06
|
1934733.1 |
"capi_get_sensors() failed, status = -1" error when running commands on the Service Processor |
2017-10-05
|
1924599.1 |
I/O error : failed to load external entity "/var/runtime/conf/frud_config.xml" |
2017-12-15
|
1909686.1 |
LDAP/SSL Groups Not Recognized Properly By ILOM |
2017-04-20
|
1671764.1 |
Replacement disk managed by LSI not recognised by OS |
2018-02-26
|
1669799.1 |
T5xx0: DIMM service LED remains lit after DIMM replacement |
2017-10-05
|
1637953.1 |
T5x20/T5x40 Server: poweron and resetsc fails: Flash in progress |
2018-05-17
|
1637803.1 |
Solaris 10 T2 series servers without FW 7.4.4.f or later can hang in shutdown due to a stuck fmd thread |
2014-03-24
|
1632323.1 |
"Hot removal of HDDx" or "/HDDx/PRSNT :Device Absent" appears upon poweron or resetting SP with System Firmware 7.3.0 or later |
2017-07-12
|
1627528.1 |
T-Series servers with LSI106x(e) (mpt driver) / LSI2x08 (mpt_sas driver) controllers reports "Command Timeout" for all internal disks (HDD/SSD) Caused by mpt/mpt_sas driver bug |
2018-03-06
|
1620275.1 |
Servicetag service not working |
2017-10-05
|
1616612.1 |
Firmware update fails with sysfwdownload: download failure - status = 2 |
2017-05-18
|
1609319.1 |
T5120/T5140/T5220/T5240/T5440, Service Processor network management port looks failed due to link speed negotiation failure with connected Gigabit Ethernet switch |
2018-05-17
|
1603789.1 |
Disk under LSI Hardware Raid (HWRaid) shows as N/A instead of a target number |
2018-01-31
|
1598815.1 |
Service Processor (ILOM ) reboots continuously reporting IO errors on T5x20 |
2017-06-06
|
1598134.1 |
Recognizing and Troubleshooting Missing or Erroneous Environmental Sensor Status output after a recent System Firmware Upgrade on Sun SPARC Enterprise T5120 Server |
2017-06-07
|
1580033.1 |
SP Resets on T5xx0, T3, T4, T5 and M5 Systems May Overwrite a User-Land Solaris Memory Page Causing In-Memory Corruption |
2018-01-22
|
1573754.1 |
Sun SPARC T5120/T5220 reports faulty DIMMs on non existent or DIMM wrong slot |
2017-09-29
|
1573070.1 |
T1000/T2000/T5xx0 - System shows ASR DB messages, slow to boot and shut down |
2017-05-01
|
1570590.1 |
SC hangs due to sccd daemon shutdown on T5x20/T5x40 Systems |
2017-10-05
|
1566088.1 |
MB/CMP0/MCUx disabled after upgrading with 8GB DIMMs |
2018-03-06
|
1561282.1 |
Troubleshooting Power Supply Issues on the T5xx0 (Netra included) platform |
2017-04-26
|
1534963.1 |
How to verify a bad disk in a cougar controlled Raid 5 array |
2017-05-01
|
1531113.1 |
T-Series Servers: Solaris messages files filled with SC Alert: Audit events (Open, Close, Activate Session) |
2017-10-05
|
1525190.1 |
Unable To Exceed 2 TB Limit On, SAS RAID HBA (SGXPCIESAS-R-INT-Z, aka Cougar) Logicaldrive |
2017-10-06
|
1524340.1 |
73GB, 146GB, and 300GB Firmware Upgrade to Prevent Disk Drive Failures in SPARC platforms. |
2018-05-09
|
1503161.1 |
Overtemp conditions for the Internal 8-port SAS RAID HBA (Cougar) in T5x20 and T5x40 |
2017-10-05
|
1500217.1 |
Sun SPARC Enterprise T5120/T5440 Server: Led amber PS_FAULT |
2018-04-02
|
1494101.1 |
"Unable To Determine Platform Id" error in ALOM on T5120/T5220 & T5140/T5240 systems |
2018-01-08
|
1490986.1 |
Multiple Fans Reported as Failed on T5220 & T5240 |
2018-04-25
|
1013102.1 |
PSH: Diagnosis Issue for T5120 and T5220 (SUN4V-8000-E2) |
2018-01-04
|