Created from <SR 3-7408074841> Applies to:Sun SPARC Enterprise T5120 Server - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsAfter upgrading/replacing the existing RAM configuration by 8GB Memory Modules, the following error may occur during server Power On Self Test: 2013-06-20 03:10:40.002 0:0:0>INFO:
2013-06-20 03:10:40.055 0:0:0> POST Passed all devices. 2013-06-20 03:10:40.109 0:0:0>POST: Return to VBSC. 2013-06-20 03:10:40.162 0:0:0>Master set ACK for vbsc runpost command and spin... ERROR: The following devices are disabled: MB/CMP0/MCU2 - in ALOM compatibility shell, the following will be shown: sc> showfaults -v
Last POST Run: Thu Jun 20 03:10:40 2013 Post Status: Passed all devices ID Time FRU Class Fault 1 Jun 20 03:06:26 /SYS/MB SP detected fault: /SYS/MB/CMP0/MCU2 Forced fail (IBIST) 2 Jun 20 03:06:28 /SYS SP detected fault: Jun 20 03:06:28 ERROR: Operating with a degraded memory configuration. sc> - the same error, shown in ILOM shell: -> show faulty
Target | Property | Value --------------------+------------------------+--------------------------------- /SP/faultmgmt/0 | fru | /SYS/MB /SP/faultmgmt/0/ | timestamp | Jun 20 03:06:26 faults/0 | | /SP/faultmgmt/0/ | sp_detected_fault | /SYS/MB/CMP0/MCU2 Forced fail faults/0 | | (IBIST) /SP/faultmgmt/1 | fru | /SYS /SP/faultmgmt/1/ | timestamp | Jun 20 03:06:28 faults/0 | | /SP/faultmgmt/1/ | sp_detected_fault | Jun 20 03:06:28 ERROR: faults/0 | | Operating with a degraded | | memory configuration.
ChangesMemory Modules of the following type have been used: CauseIBIST fails channel initialization on a single Memory Control Unit (MCU) on first initialization only, Solution1) Re-enable the MCU (MCU2 in this case) by executing: 2) Clear the faults b) if in ALOM compatibility shell, you should still see faults in "sc> showfaults -v" 3) power down the server and remove power cables, Re-seat the memory modules. References<BUG:15778946> - SUNBT7153775 IBIST MCU CHANNEL INITIALISATION FAILURES AFTER INSTALLING 8GB DIMMAttachments This solution has no attachment |
||||||||||||||||||||
|