![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1598134.1 : Recognizing and Troubleshooting Missing or Erroneous Environmental Sensor Status output after a recent System Firmware Upgrade on Sun SPARC Enterprise T5120 Server
In this Document
Created from <SR 3-8048037721> Applies to:Sun SPARC Enterprise T5120 Server - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsEnvironmental sensor data missing or erroneous from Sun SPARC Enterprise T5120 Server's ALOM "showenvironment" output and Sensors showing Disabled in OS "prtdiag -v" output. Example sc> showenvironment
-------------------------------------------------------------------------------- System Temperatures (Temperatures in Celsius): -------------------------------------------------------------------------------- Sensor Status Temp LowHard LowSoft LowWarn HighWarn HighSoft HighHard -------------------------------------------------------------------------------- /SYS/MB/T_AMB OK 34 -10 -5 0 50 55 60 /SYS/MB/CMP0/T_TCORE UNKNOWN -- -- -- -- -- -- -- <--- Status "Unknown" /SYS/MB/CMP0/T_BCORE UNKNOWN -- -- -- -- -- -- -- <--- Status "Unknown" /SYS/MB/CMP0/BR0/CH0/D0/T_AMB OK 61 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR0/CH0/D1/T_AMB OK 51 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR0/CH1/D0/T_AMB OK 61 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR0/CH1/D1/T_AMB OK 57 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR1/CH0/D0/T_AMB OK 61 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR1/CH0/D1/T_AMB OK 59 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR1/CH1/D0/T_AMB OK 63 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR1/CH1/D1/T_AMB OK 57 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR2/CH0/D0/T_AMB OK 63 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR2/CH0/D1/T_AMB OK 61 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR2/CH1/D0/T_AMB OK 66 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR2/CH1/D1/T_AMB OK 56 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR3/CH0/D0/T_AMB OK 64 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR3/CH0/D1/T_AMB OK 57 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR3/CH1/D0/T_AMB OK 67 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR3/CH1/D1/T_AMB OK 53 -10 -8 -5 95 100 105 . . . -------------------------------------------------------------------------------- Voltage sensors (in Volts): -------------------------------------------------------------------------------- Sensor Status Voltage LowSoft LowWarn HighWarn HighSoft -------------------------------------------------------------------------------- /SYS/MB/V_+3V3_MAIN OK 3.34 3.06 3.10 3.49 3.53 /SYS/MB/V_+12V0_MAIN OK 12.22 10.90 11.15 12.85 13.10 /SYS/MB/V_VDDIO OK 1.12 1.00 1.02 1.18 1.20 <--- Short List, missing 5 other values -------------------------------------------------------------------------------- Power Supplies: -------------------------------------------------------------------------------- Supply Status Fan_Fault Temp_Fault Volt_Fault Cur_Fault -------------------------------------------------------------------------------- /SYS/PS0 OK OFF OFF OFF OFF /SYS/PS1 OK OFF OFF OFF OFF
$ prtdiag -v
System Configuration: Sun Microsystems sun4v SPARC Enterprise T5120 <snip> Temperature sensors: ------------------------------------------------------------ Location Sensor Status ------------------------------------------------------------ SYS/MB T_AMB ok SYS/MB/CMP0/BR0/CH0/D0 T_AMB ok SYS/MB/CMP0/BR0/CH0/D1 T_AMB ok SYS/MB/CMP0/BR0/CH1/D0 T_AMB ok SYS/MB/CMP0/BR0/CH1/D1 T_AMB ok SYS/MB/CMP0/BR1/CH0/D0 T_AMB ok SYS/MB/CMP0/BR1/CH0/D1 T_AMB ok SYS/MB/CMP0/BR1/CH1/D0 T_AMB ok SYS/MB/CMP0/BR1/CH1/D1 T_AMB ok SYS/MB/CMP0/BR2/CH0/D0 T_AMB ok SYS/MB/CMP0/BR2/CH0/D1 T_AMB ok SYS/MB/CMP0/BR2/CH1/D0 T_AMB ok SYS/MB/CMP0/BR2/CH1/D1 T_AMB ok SYS/MB/CMP0/BR3/CH0/D0 T_AMB ok SYS/MB/CMP0/BR3/CH0/D1 T_AMB ok SYS/MB/CMP0/BR3/CH1/D0 T_AMB ok SYS/MB/CMP0/BR3/CH1/D1 T_AMB ok SYS/MB/CMP0 T_TCORE disabled SYS/MB/CMP0 T_BCORE disabled . . . Voltage sensors: ------------------------------------------------------------ Location Sensor Status ------------------------------------------------------------ SYS/MB V_VMEML disabled SYS/MB V_VMEMR disabled SYS/MB V_+3V3_STBY disabled SYS/MB V_VCORE disabled SYS/MB V_+3V3_MAIN ok SYS/MB V_VDDIO ok SYS/MB V_+12V0_MAIN ok SYS/MB V_VBAT disabled SYS/PS0 V_IN_MAIN ok SYS/PS0 V_OUT_MAIN ok SYS/PS1 V_IN_MAIN ok SYS/PS1 V_OUT_MAIN ok Voltage indicators: ------------------------------------------------------------ Location Indicator Condition ------------------------------------------------------------ SYS/MB VCORE_POK disabled SYS/MB VMEML_POK disabled SYS/MB VMEMR_POK disabled SYS/PS0 AC_POK ok SYS/PS0 DC_POK ok SYS/PS0 VOLT_FAULT ok SYS/PS1 AC_POK ok SYS/PS1 DC_POK ok SYS/PS1 VOLT_FAULT ok
ChangesA recent recommended system firmware update was done by the user. CauseThe cause of this issue is an Incomplete Firmware Update. sc> showenvironment
-------------------------------------------------------------------------------- System Temperatures (Temperatures in Celsius): -------------------------------------------------------------------------------- Sensor Status Temp LowHard LowSoft LowWarn HighWarn HighSoft HighHard -------------------------------------------------------------------------------- /SYS/MB/T_AMB OK 36 -10 -5 0 50 55 60 /SYS/MB/CMP0/T_TCORE OK 73 -14 -9 -4 86 98 106 /SYS/MB/CMP0/T_BCORE OK 72 -14 -9 -4 86 98 106 /SYS/MB/CMP0/BR0/CH0/D0/T_AMB OK 62 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR0/CH0/D1/T_AMB OK 52 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR0/CH1/D0/T_AMB OK 62 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR0/CH1/D1/T_AMB OK 59 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR1/CH0/D0/T_AMB OK 62 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR1/CH0/D1/T_AMB OK 60 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR1/CH1/D0/T_AMB OK 64 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR1/CH1/D1/T_AMB OK 58 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR2/CH0/D0/T_AMB OK 65 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR2/CH0/D1/T_AMB OK 62 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR2/CH1/D0/T_AMB OK 67 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR2/CH1/D1/T_AMB OK 57 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR3/CH0/D0/T_AMB OK 65 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR3/CH0/D1/T_AMB OK 59 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR3/CH1/D0/T_AMB OK 68 -10 -8 -5 95 100 105 /SYS/MB/CMP0/BR3/CH1/D1/T_AMB OK 54 -10 -8 -5 95 100 105 . . . -------------------------------------------------------------------------------- Voltage sensors (in Volts): -------------------------------------------------------------------------------- Sensor Status Voltage LowSoft LowWarn HighWarn HighSoft -------------------------------------------------------------------------------- /SYS/MB/V_+3V3_STBY OK 3.34 3.13 3.17 3.53 3.60 /SYS/MB/V_+3V3_MAIN OK 3.34 3.06 3.10 3.49 3.53 /SYS/MB/V_+12V0_MAIN OK 12.22 10.90 11.15 12.85 13.10 /SYS/MB/V_VDDIO OK 1.12 1.00 1.02 1.18 1.20 /SYS/MB/V_VCORE OK 1.27 1.15 1.19 1.36 1.38 /SYS/MB/V_VMEML OK 1.84 1.64 1.68 1.93 1.98 /SYS/MB/V_VMEMR OK 1.85 1.64 1.68 1.93 1.98 /SYS/MB/V_VBAT OK 3.20 -- 2.69 -- -- -------------------------------------------------------------------------------- Power Supplies: -------------------------------------------------------------------------------- Supply Status Fan_Fault Temp_Fault Volt_Fault Cur_Fault -------------------------------------------------------------------------------- /SYS/PS0 OK OFF OFF OFF OFF /SYS/PS1 OK OFF OFF OFF OFF
$ prtdiag -v
System Configuration: Sun Microsystems sun4v SPARC Enterprise T5120 Temperature sensors: ------------------------------------------------------------ Location Sensor Status ------------------------------------------------------------ SYS/MB T_AMB ok SYS/MB/CMP0/BR0/CH0/D0 T_AMB ok SYS/MB/CMP0/BR0/CH0/D1 T_AMB ok SYS/MB/CMP0/BR0/CH1/D0 T_AMB ok SYS/MB/CMP0/BR0/CH1/D1 T_AMB ok SYS/MB/CMP0/BR1/CH0/D0 T_AMB ok SYS/MB/CMP0/BR1/CH0/D1 T_AMB ok SYS/MB/CMP0/BR1/CH1/D0 T_AMB ok SYS/MB/CMP0/BR1/CH1/D1 T_AMB ok SYS/MB/CMP0/BR2/CH0/D0 T_AMB ok SYS/MB/CMP0/BR2/CH0/D1 T_AMB ok SYS/MB/CMP0/BR2/CH1/D0 T_AMB ok SYS/MB/CMP0/BR2/CH1/D1 T_AMB ok SYS/MB/CMP0/BR3/CH0/D0 T_AMB ok SYS/MB/CMP0/BR3/CH0/D1 T_AMB ok SYS/MB/CMP0/BR3/CH1/D0 T_AMB ok SYS/MB/CMP0/BR3/CH1/D1 T_AMB ok SYS/MB/CMP0 T_TCORE ok SYS/MB/CMP0 T_BCORE ok . . . Voltage sensors: ------------------------------------------------------------ Location Sensor Status ------------------------------------------------------------ SYS/MB V_VMEML ok SYS/MB V_VMEMR ok SYS/MB V_+3V3_STBY ok SYS/MB V_VCORE ok SYS/MB V_+3V3_MAIN ok SYS/MB V_VDDIO ok SYS/MB V_+12V0_MAIN ok SYS/MB V_VBAT ok SYS/PS0 V_IN_MAIN ok SYS/PS0 V_OUT_MAIN ok SYS/PS1 V_IN_MAIN ok SYS/PS1 V_OUT_MAIN ok Voltage indicators: ------------------------------------------------------------ Location Indicator Condition ------------------------------------------------------------ SYS/MB VCORE_POK ok SYS/MB VMEML_POK ok SYS/MB VMEMR_POK ok SYS/PS0 AC_POK ok SYS/PS0 DC_POK ok SYS/PS0 VOLT_FAULT ok SYS/PS1 AC_POK ok SYS/PS1 DC_POK ok SYS/PS1 VOLT_FAULT ok
SolutionPlease acquire a fresh copy of the Firmware patch and follow the steps in the install.info file to install the Firmware anew.* *If after implementing the above suggested solution the issue remains, please open a new Oracle Service Request with the latest gathered Explorer for further analysis. Attachments This solution has no attachment |
||||||||||||||||||||
|