How To Canned Action Plan (CAP) Documents Last Modified Date
1340219.1 How to Remove and Replace a SE3310/3320 JBOD RAID Chassis-Midplane:ATR:1340219.1:3 2016-01-20
1312976.1 How to Remove and Replace a SE3310/3320 Power Supply:ATR:1401:3 2016-07-28
1312968.1 How to Remove and Replace a SE3310/3320 LED/Reset Switch Board:ATR:1402:1 2016-07-28
1312955.1 How to Remove and Replace a SE3310/3320 SCSI Cable:ATR:1399:1 2016-07-28
1312944.1 How to Remove and Replace a SE3310/3320 EMU Card:ATR:1398:1 2016-07-28
1312935.1 How to Remove and Replace a SE3310/3320 Battery:ATR:1397:3 2016-07-28
1311844.1 How to Remove and Replace a SE3310/3320 Internal Terminator LVD Module:ATR:1403:3 2016-07-28
1311827.1 How to Remove and Replace a SE3310/3320 JBOD SCSI I/O Module:ATR:1395:3 2016-07-28
1311816.1 How to Remove and Replace a SE3310/3320 RAID Controller:ATR:2889:3 2016-07-28
1305704.1 How to update Sun Storage 3510, 3511, 3310 or 3320 Controller Firmware ATR:1305704.1:0 2016-02-19
1010064.1 Sun Storage 3000 Arrays: How to Replace a Hard Drive 2017-03-23
1003692.1 Sun StorEdge 3310/3320/3510/3511: How To Replace A Failed Disk In A Logical Drive:ATR:1013:3 2018-01-08
How To Non CAP Knowledge Documents Last Modified Date
1985393.1 Sun StorEdge 3000 Arrays: How to Access the Firmware Menu Using the SSH Protocol 2016-06-30
1500079.1 Sun Storage 3000 Arrays: How to Proactively Fail and Remove a Failing Disk 2018-04-20
1020944.1 Sun Storage 3000 Arrays: Hints on Preventing Over-Temp Conditions 2014-05-23
1019030.1 Sun Storage 3120, 33x0 SCSI and 351x FC Arrays: Support for mixed Spindle Speeds (RPMs) in arrays and expansion units 2013-08-12
1018819.1 Sun StorEdge 3310 SCSI Array: Basic Configuration for Solaris Hosts 2013-06-06
1018772.1 Setting Passwords on the Sun StorEdge SE3310, 3320, 3510 and 3511 Arrays 2018-04-02
1018173.1 Drives may be marked BAD upon upgrade to 4.13 firmware which may be good drives. 2013-11-21
1018123.1 StorEdge[TM] PCI Dual Ultra3 SCSI Host Adapter Requirements 2016-11-01
1017949.1 Sun StorEdge[TM] 3310/3510/3511 Firmware: View and edit logical drive menu for firmware 4.xx 2016-02-09
1017748.1 Sun Storage 351x Arrays: Setting Battery Date After Replacement 2017-07-21
1017719.1 Sun StorEdge[TM] 351x/33x0: Telnet session problems with 3.2x Controller Firmware 2013-08-12
1012343.1 Sun Storage 3000 Arrays: How to Collect Support Information 2017-01-30
1012313.1 Sun Storage 3310 and 3320 Arrays: How to Identify Disk IDs and Correct Backend Cabling 2018-05-01
1012254.1 Sun Storage 3000 Arrays: Saving and Restoring NVRAM and Logical Drive Configuration 2018-01-08
1011735.1 How to Add New Storage Disk Devices to Solaris[TM] Without Performing a Reconfiguration Boot 2017-06-04
1011431.1 Troubleshooting Sun Storage 3000 Array Series Hardware 2017-03-20
1010987.1 Oracle Explorer Data Collector: How to Get se3kxtr in Out-of-Band Status 2018-03-20
1010810.1 Sun Storage 33x0/351x Arrays: How to resolve "DRAM parity error detected" 2018-05-17
1010657.1 The Proper Way to De-stage Cache in a Sun StorEdge[TM] 351x/33x0 Array is to Use the "shutdown" Command 2016-03-09
1010542.1 Sun StorEdge[TM] 3310: Seeing more than 8 LUNs when the array is attached to a host's on-board SCSI port 2013-08-12
1010511.1 Sun[TM] StorageTek 3000 Array: Resetting Factory Defaults 2013-08-12
1009716.1 Sun Storage 3000 Arrays: Steps to Verify Configuration Parameter Settings 2017-03-01
1009274.1 Sun StorEdge[TM] 3510 FC Array: Understanding The Internal Loop Architecture During Controller Failover 2018-03-04
1009219.1 Sun Storage 3000 RAID Arrays: RAID-0 Disk Failure Recovery Process 2017-06-12
1009168.1 Sun StorEdge[TM] 33x0/351x Host Channel Port IDs 2013-08-12
1008932.1 Deletion or modification of a partition on the Sun StorEdge[TM] 33x0 SCSI and Sun StorEdge 3510 FC & 3511SATA arrays with FW 4.x. 2013-08-12
1008840.1 Sun StorEdge[TM] 3310: How are disks mirrored in RAID 1+0? 2013-08-12
1008196.1 Recreate lun mapping from show configuration on a Sun StorEdge[TM]3000 array 2016-11-02
1007816.1 Sun Storage 3000 Arrays: Interpreting Disk Drive LEDs 2017-03-22
1006955.1 Sun Storage[TM] 3000 Arrays: Cheatsheet for Documentation References Before Replacing an I/O Controller 2013-08-12
1006374.1 Sun StorEdge[TM] 3310 Disk firmware patch number 2013-08-12
1005598.1 How to partition a logical drive on a Sun StorageTek[TM] 3310, 3320, 3510 or 3511 array [Video] 2014-02-28
1005597.1 How do I configure a local/global spare on a Sun Storage 3310, 3320, 3510 or 3511 Array? [Video] 2014-02-28
1005475.1 What is the meaning of the message: "drive not available: formatting" from the Solaris [TM] format(1m) utility? 2017-10-05
1005314.1 Sun Storage 3310 and 3320 Arrays: How to Verify SCSI HBA Connnectivity 2014-09-26
1005129.1 Sun Cluster[TM] 3.x software: scsi-initiator-id setup in clusters with Sun StorEdge[TM] 3xx0 SCSI arrays 2013-08-12
1005062.1 Sun Storage 3000 Arrays: How to Configure and Unconfigure Global Spares Using sccli 2018-04-02
1004831.1 How to Connect and Configure Sun Storage 3310/3320 Arrays in a Cluster 2013-08-12
1004789.1 Sun Storage 3310 Array: How to Discover the Array in Sun StorEdge Configuration Service 2014-08-05
1004774.1 Sun Storage 3000 Arrays: How to Reset the Array Password 2018-03-14
1004772.1 Sun StorEdge[TM] 3510 FC Array/Sun StorEdge[TM] 3310:Symptom:Firmware version shown in label on 'format' output is out of date 2013-08-12
1004759.1 Sun Storage 3000 Arrays: How to Access Arrays Out-of-band 2015-01-14
1004355.1 How do I create a logical drive on a Sun StorageTek[TM] 3310,3320,3510 or 3511 array? [Video] 2016-06-30
1004352.1 How to Download and Install Sun Storage Configuration Service Software (SUNWsscs) 2017-12-01
1003908.1 Sun Storage 3310/3320/3510/3511: SSE or FE steps to follow to assist with RCA. 2017-06-12
1003631.1 Implications of Predictable Failure Test on Sun StorEdge[TM] 3000 Family with Firmware 4.11 2013-08-12
1003605.1 StorEdge 3310, 3320, 3510, 3511: Failed Component Beep Codes 2017-06-12
1003591.1 Sun StorEdge[TM] 3310 SCSI Array: Can't Install Patch 112706-03 2013-08-12
1003584.1 Sun StorEdge[TM] 3000 Series Arrays: How to Reset the Minnow to Factory Default Settings or Saved Settings to the Disks. 2015-05-13
1003561.1 Sun StorEdge[TM] 33x0 and 351x: Host Channel LUN Assignments 2013-08-12
1003542.1 How To Setup SSCS Monitoring For Sun StorEdge[TM] 3000 Arrays 2018-03-27
1003527.1 Sun Storage 3000 Arrays: How to Create and Map Logical Drive Partitions 2016-04-01
1003147.1 Understanding single and dual bus configurations in the Sun StorEdge[TM] 33x0 2016-01-03
1002906.1 How to create or change primary and secondary IDs on a StorEdge(TM) 33x0 and 351x Array [Video] 2013-08-12
1002880.1 How do I set up /kernel/drv/sd.conf for Sun StorEdge[TM] 3120,3310 and 3320 arrays? [Video] 2013-08-12
1002442.1 Sun Storage 3000 Arrays: How to Set Date and Time 2014-08-05
1002426.1 Battery Replacement Procedure for Sun StorEdge 3310SCSI/3510FC/3511FC Arrays 2017-04-20
1002402.1 Sun StorEdge[TM] 33x0/3510/3511: What does the "M" mean in the show disks output 2013-08-12
1002298.1 Best Practices: configuring target id's on Sun StorEdge[TM] 3xx0 arrays 2013-08-12
1002266.1 How to convert a Sun StorEdge[TM] 33x0/351x single controller array to a dual controller array 2013-08-12
1002130.1 Sun StorEdge[TM] 33x0/351x: How to reset "disk Reserved space" on a disk drive 2013-10-23
1001992.1 Solaris Cluster 3.x How to Change SCSI JBOD Disk Under Veritas Volume Manager 3.x 2018-01-16
1001903.1 Sun Storage 3000 Arrays: How to Log Events to /var/adm/messages 2016-10-02
1001781.1 Sun StorEdge[TM] A5x00, T3, 6120, 33xx, 351xFC, A3500FC Arrays: Disk Firmware/Patch Matrix Summary 2016-12-28