Asset ID: |
1-71-1001781.1 |
Update Date: | 2016-12-28 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1001781.1
:
Sun StorEdge[TM] A5x00, T3, 6120, 33xx, 351xFC, A3500FC Arrays: Disk Firmware/Patch Matrix Summary
Related Items |
- Sun Storage 3511 SATA Array
- Sun Storage 6120 Array
- Sun Storage 3310 Array
- Sun Storage 3510 FC Array
- Sun Storage T3 Array
- Sun Storage A3500 FC Array
- Sun Storage A5000 Array
- Sun Storage A5200 Array
- Sun Storage A3500 SCSI Array
- Sun Storage 3320 SCSI Array
|
Related Categories |
- PLA-Support>Sun Systems>DISK>Arrays>SN-DK: A1000_A3xxx
- _Old GCS Categories>Sun Microsystems>Storage - Disk>Modular Disk - Other
|
PreviouslyPublishedAs
202434
Applies to:
Sun Storage A3500 SCSI Array - Version Not Applicable and later Sun Storage 3310 Array - Version Not Applicable and later Sun Storage 3511 SATA Array - Version Not Applicable and later Sun Storage 6120 Array - Version Not Applicable and later Sun Storage A3500 FC Array - Version Not Applicable and later All Platforms
Goal
This document lists the disk firmware for the Sun StorEdge[TM] A5x00, T3, 6120, 33xx, 351xFC, A3500FC Arrays.
Solution
For letters in brackets e.g. "(c)", see Notes section below.
OS
|
Sun StorEdge[TM] A5x00 / A3500 / T3 / T3+ / SE6120
|
Sun StorEdge 33xx/SE351x
|
|
Patches Basic
Function(s)
|
SSA / A5x00 / E3500 / T3 Patches
|
A5x00
IB
F/W
|
FCode
|
FC- AL
Disc
F/W
|
6120
Firmware
|
T3 / T3+ Firmware
|
Patches
|
3310
F/W
|
351x
F/W
|
|
|
|
|
SOC+HA
FC100/s
|
I/O SysBd
|
QLC21xx FC100/p
|
QLC22xx
(n, p)
|
QLC23xx
(n, p)
|
|
Boot
|
UIC
F/W
|
Boot
T3/T3+
|
Loop
|
EProm
(q)
|
|
|
|
Solaris[TM]
2.6 Operating
System
(OS)
|
OBP & SOC+ FCode
Kernel
SSD
SES
IB, Socal, luxadm & sf
Luxadm man page
Format
ifp (PCI only)
T3 Disc & H/W F/W
T3+ Disc & H/W F/W
6120 Disc & H/W F/W
FC100/p FCode(PCI)
FC100/s FCode(Sbus)
Disc F/W (A5x00)
Disc F/W (A5x00, T3)
IBM Disc F/W(T3/T3+)
|
103346-xx (c)
105181-39 (g,f)
105356-23
105357-04 (h)
105375-29
106219-03
106226-03
107280-08
109115-17 (c, s)
116930-07
116931-22 (c)
109399-03 (c)
109400-03 (c)
109962-14 (c, f)
111535-03 (s)
113668-04
114704-02 (v)
|
1.09
|
1.13 (c)
|
1.8.30 (c)
|
1.9 (c)
|
N/A
|
N/A
|
N/A
|
See
Tables 1 - 4
(d)
|
N/A
|
N/A
|
1.18.04 / 3.2.6
|
5.02
|
2.10 (q)
|
113722-18
113723-21
113724-12
|
423C
N/A
N/A
|
N/A
423A (a)
423A (a)
|
Solaris 7 OS
|
OBP & SOC+ FCode
Kernel
ifp (PCI only)
SSD( incl. in kernel patch )
Socal & sf
SES
IB & luxadm
ifp macros (PCI only)
fsck
Dkio.h & commands.h
FC adb
T3 Disc & H/W F/W
T3+ Disc & H/W F/W
6120 Disc & H/W F/W
fctl & fp
fcp
usoc FC transport
FC100/p FCode(PCI)
FC100/s FCode(Sbus)
Qlc 22xx
Disc F/W (A5x00)
Disc F/W (A5x00, T3)
IBM Disc F/W(T3/T3+)
Qlc 2200 FCode
|
103346-xx (c)
106541-42 (f)
107292-09 (f)
106541-42 (f)
107469-09
107472-02 (h)
107473-07
107474-01 (f)
107544-03 (f)
107834-04 (f)
108203-05
109115-17 (c, s)
116930-07
116931-22 (c)
109116-04
109117-05
109118-02
109399-03 (c)
109400-03 (c)
109787-04 (f)
109962-14 (c, f)
111535-03 (s)
113668-04 (s)
114704-02 (v)
111853-04(c, f)
|
1.09
|
1.13 (c)
|
1.8.30 (c)
|
1.9 (c)
|
N/A
|
N/A
|
N/A
|
See
Tables 1 - 4
(d)
|
N/A
|
N/A
|
1.18.4 / 3.2.6
|
5.02
|
2.10 (q)
|
113722-18
113723-21
113724-12
|
423C
N/A
N/A
|
N/A
423A
423A
|
Solaris 8 OS
|
OBP & SOC+ FCode
Kernel
T3 Disc & H/W F/W
T3+ Disc & H/W F/W
6120 Disc & H/W F/W
FC100/p FCode(PCI)
FC100/s FCode(Sbus)
ifp (PCI only)
Socal & sf
SSD
SES
Luxadm
Disc F/W (A5x00)
Disc F/W (A5x00, T3)
IBM Disc F/W(T3/T3+)
SAN found. Kit
Common SNIA
Sun SNIA
fctl, fcp & fp
fcip
Qlc 22xx
Multi-Path(smts/mpxio)
Luxadm
fscm
fctl, fcp & fp
fcip
Qlc 22xx, 23xx
cfgadm fp-plugin
fopen
Qlc 22xx FCode
Qlc 23xx FCode
|
103346-xx (c)
108528-29(f)
109115-17 (c, s)
116930-07
116931-22 (c)
109399-03 (c)
109400-03 (c)
109189-05
109460-10
108974-45
110614-02
109529-06
109962-14 (c,f)
111535-03 (s)
113668-04 (s)
114704-02 (v)
111847-08
114475-05
113766-04
108982-10
108983-08
108984-08
111412-18
111413-18 (f)
114475-05 (f)
111095-25 (f)
111096-13 (f)
111097-20 (f)
111846-08
111588-05
111853-04 (f)
112244-04 (f)
114873-03 (f)
114874-03 (f)
|
1.09
|
1.13 (c)
|
1.8.30 (c)
|
1.9 (c)
|
1.14.10
|
1.14.05
|
1.14.11
|
See
Tables 1 & 2
(d)
|
3.2.2
|
7.23
|
1.18.4 / 3.2.6
|
5.02
|
2.10 (q)
|
113722-18
113723-21
113724-12
|
423C
N/A
N/A
|
N/A
423A
423A
|
Solaris 9 OS
|
SAN found. Kit
Common SNIA
Sun SNIA
fcp
luxadm &liba5k
Multi-Path(smts/mpxio)
fctl, fcp & fp
fcip
Qlc 22xx, 23xx
Luxadm
fscm
cfgadm fp-plugin
sd & ssd
T3 Disc & H/W F/W
T3+ Disc & H/W F/W
6120 Disc & H/W F/W
Disc F/W (A5x00)
Disc F/W (A5x00, T3)
IBM Disc F/W(T3/T3+)
FC100/p FCode(PCI)
FC100/s FCode(Sbus)
Qlc 22xx FCode
Qlc 23xx FCode
SVM
|
111847-08
114477-03
114478-07
113046-01
113049-01
113039-11
113040-17
113041-10
113042-12
113043-12
114476-06
113044-05
113277-37
109115-17 (c,s)
116930-07
116931-22 (c)
109962-14 (t)
111535-03 (s)
113668-04 (s)
114704-02 (v)
109399-03 (c)
109400-03 (c)
111853-04 (f)
112244-04 (f)
114873-03 (f)
114874-03 (f)
113026-19
113276-04
|
1.09
|
1.13 (c)
|
1.8.30 (c)
|
1.9 (c)
|
1.14.10
|
1.14.05
|
1.14.11
|
See
Tables 1 & 2
(d)
|
3.2.2
|
7.23
|
1.18.4 / 3.2.6
|
5.02
|
2.10 (q)
|
113722-18
113723-21
113724-12
|
423C
N/A
N/A
|
N/A
423A
423A
|
Solaris 10 OS
|
OBP & SOC+ FCode
Kernel
Common SNIA
luxadm &liba5k
Multi-Path(scsi_vhci)
Fibrechannel drivers
cfgadm fp-plugin
sd & ssd
T3 Disc & H/W F/W
T3+ Disc & H/W F/W
6120 Disc & H/W F/W
Disc F/W (A5x00)
Disc F/W (A5x00, T3)
IBM Disc F/W(T3/T3+)
FC100/p FCode(PCI)
FC100/s FCode(Sbus)
Qlc 22xx FCode
Qlc 23xx FCode
|
103346-xx (c)
118822-20
120346-01
119470-06
119715-05
119130-13
119974-02
119374-08
109115-17 (c,s)
116930-07
116931-22(c)
109962-14 (t)
111535-03 (s)
113668-04 (s)
114704-02 (v)
109399-03 (c)
109400-03 (c)
111853-04 (f)
112244-04 (f)
114873-03 (f)
114874-03 (f)
|
1.09
|
1.13 (c)
|
1.8.30 (c)
|
1.9 (c)
|
1.14.10
|
1.14.05
|
1.14.11
|
See
Tables 1 & 2
(d)
|
3.2.2
|
7.23
|
1.18.4 / 3.2.6
|
5.02
|
2.10 (q)
|
113722-18
113723-21
113724-12
|
423C
N/A
N/A
|
N/A
423A
423A
|
|
SUNW/VRTS
Vm(e,r)
SVM
|
STORtools
|
Component Manager (j)
|
NWS/RAS Agent
|
|
|
|
|
|
|
|
|
|
|
|
Vm (e)
|
Patches (e)
|
SVM
|
Patches
|
STORtools
|
Patches
|
CM
|
Patches
|
NWS/RAS
|
Patches
|
Solaris 2.6 OS
|
2.5
2.6
3.0.4
3.1
3.1.1
3.2
|
105463-10
106606-04
110261-05
110253-04
110451-09
111122-07
113201-05
111904-07
|
4.1
4.2
|
104172-24
104275-01
107195-01
104173-24
107196-01
106627-19
106628-19
|
3.3
|
109090-xx
106219-03
|
1.0
2.0
2.1
2.2
|
108368-01 (k)
108390-01 (k)
108882-01
108888-01
108944-01 (l)
None
None
|
2.0
2.1
|
None
111893-04
|
Solaris 7 OS
|
3.0.4
3.1
3.1.1
3.2
3.5
4.0
|
110262-05
110254-04
110452-09
111122-07
113201-05
111904-07
112392-06
113203-03
113595-04
113596-03
115217-05
120585-01
115209-20
117081-01
115210-20
117094-03
117276-02
117093-02
119744-11
|
4.2
|
106627-19
106628-19
|
3.3
|
109090-xx
107473-07
|
1.0
2.0
2.1
2.2
|
108368-01 (k)
108391-01 (k)
108882-01
108888-01
108944-01 (l)
None
None
|
2.0
2.1
|
None
111893-04
|
Solaris 8 OS
|
3.0.4
3.1
3.1.1
3.2
3.5
4.0
4.1
|
110263-05
110255-04
111118-10
111122-07
113201-05
111904-07
same as S7
same as S7
117080-02
|
4.2.1
|
108693-26
111755-02
108694-21
|
3.3
4.0.1
4.1
4.2
|
109090-xx
109529-06
111413-14 (f)
None (r)
111774-01 (r)
None
|
2.0
2.1
2.2
|
108882-01
108888-01
108944-01 (l)
None
None
|
2.0
2.1
|
None
111893-04
|
Solaris 9
(x)
|
3.2s9
3.5
4.0
4.1
|
112385-06
113695-02
same as S7
same as S7
same as S8
|
|
113073-14
|
3.3
4.0.1
4.1
4.2
|
None
None (r)
None (r)
None
|
N/A
|
N/A
|
N/A
N/A
|
N/A
N/A
|
Solaris 10
|
4.1
|
same as S8
|
|
118822-25
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
Table 1 (Seagate)
Storage Cap
|
9Gbyte
|
18 Gbyte
|
36 Gbyte
|
Vendor Nbr
|
ST19171FC
|
ST39102FC
|
ST39103FC
|
ST118273F
|
ST118202F
|
ST318203F
|
ST318304F
|
ST136403F
|
ST336704F
|
ST336605F
|
ST336607F
|
ST336752F
|
ST336753F
|
F/W, size,
A5K patch
|
7F7x, 1.6" 109962-14
(y)
|
1129, 1"
109962-14
(y)
|
144B, 1"
111535-03
(y)
|
8854, 1.6"
109962-14
(y)
|
N/A
|
114A, 1"
111535-03
(y)
|
1526, 1"
113668-04
(y)
|
144A, 1.6"
111535-03
(y)
|
1526, 1"
113668-04
(y)
|
0638 (s), 1"
109962-14
(y)
|
0407, 1"
113671-03
|
0608, 1"
109962-14
|
0449, 1"
116748-07
|
F/W, size,
T3/T3+
|
N/A
|
N/A
|
N/A
|
N/A
|
9329, 1.6"
109115-17
|
DF4A, 1"
109115-17
|
AF26, 1"
109115-17
|
DF4A, 1.6"
109115-17
|
AE26 1"
109115-17
|
A638 (s), 1"
109115-17
|
A507, 1"
112276-13 or 116930-07
|
A608, 1"
112276-13
|
A449, 1"
112276-13
|
F/W, size,
6120
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
0407, 1"
113671-03
|
0708, 1"
113672-01
|
0449, 1"
116748-07
|
F/W, size,
SE35xx
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
0407, 1"
113671-03
|
0508, 1"
N/A
|
0449, 1"
116748-07
|
Table1 (Seagate) Continued..
Storage Cap
|
73 Gbyte
|
146Gbyte
|
180Gbyte
|
Vendor Nbr
|
ST173404F
|
ST373405F
|
ST373307F
|
ST373453F
|
ST3146807F
|
ST1181677F
|
F/W, size,
A5K patch
|
N/A
|
0638 (s), 1"
109962-14
(y)
|
0407, 1"
114708-06
|
0449, 1"
113673-04
|
0407, 1"
114709-07
|
N/A
|
F/W, size,
T3/T3+
|
AE27, 1.6"
109115-17
|
A638 (s), 1"
109115-17
|
A407, 1"
109115-17
|
N/A
|
N/A
|
A30A, 1.6"
112276-13
|
F/W, size,
6120
|
N/A
|
N/A
|
0407, 1"
114708-06
|
0449, 1"
113673-04
|
0407, 1"
114709-07
|
N/A
|
F/W, size,
SE35xx
|
N/A
|
0638, 1"
N/A
|
0407, 1"
114708-06
|
0449, 1"
113673-04
|
0407, 1"
114709-07
|
N/A
|
Table 2 (Fujitsu)
Storage Cap
|
36GBGbyte
|
73Gbyte
|
146Gbyte
|
Vendor Nbr
|
MAP3364FC
|
MAN3367FC
|
MAS3367FC
|
MAP3735FC
|
MAN3735FC
|
MAS3735FC
|
MAP3147FC
|
F/W, size,
A5K patch
|
N/A
|
1504, 1
115180-08
|
0901, 1"
116816-04
|
1701, 1"
116514-09
|
1004, 1"
116513-01
|
0901, 1"
116817-04
|
1701, 1"
116815-07
|
F/W, size,
T3/T3+ patch
|
1201, 1"
109115-17
|
1504, 1"
115180-08
|
0501, 1"
115180-08
|
1201, 1"
112276-13
|
1504, 1"
112276-13
|
N/A
|
NA
|
F/W, size,
T4/6120 patch
|
N/A
|
1504, 1"
115180-08
|
0901, 1"
116816-04
|
1701, 1"
116514-09
|
1004, 1"
116513-01
|
0901, 1"
116817-04
|
1701, 1"
116815-07
|
F/W, size,
SE35xx patch
|
N/A
|
1501, 1"
N/A
|
0701, 1"
N/A
|
1701, 1"
116514-09
|
1004, 1"
N/A
|
0701, 1"
N/A
|
1701, 1"
116815-07
|
Table 3 (Hitachi)
Storage Cap
|
36 Gbyte
|
72 Gbyte
|
146 Gbyte
|
Vendor Nbr
|
DK32EJ36F
|
DK32EJ72F
|
DK32EJ146
|
F/W, size,
T3/T3+
|
|
FQ0C, 1"
None
|
|
F/W, size,
6120 patch
|
2Q0J, 1"
116463-02
|
2Q0J, 1"
116464-02
|
2Q0J, 1"
116465-02
|
F/W, size,
SE35xx patch
|
|
|
|
Table 5 (IBM)
Storage Cap
|
18 Gbyte
|
36 Gbyte
|
Vendor Nbr
|
DDYF-T18350
|
DDYF-T36950
|
F/W, size,
T3 /T3+
|
F65Y, 1"
114704-02
|
F65Y, 1"
114704-02
|
Table 4 (Seagate SCSI)
Storage Cap
|
36 GBGbyte
|
73 Gbyte
|
147 Gbyte
|
Vendor Nbr
|
ST336605LC
|
ST336607LC
|
ST336753LC
|
ST373307LC
|
ST373453LC
|
ST3146807FC
|
F/W, size,
SE3310+ patch
|
0638 (s), 1"
N/A
|
0507, 1"
N/A
|
0349
N/A
|
0507, 1"
N/A
|
0349, 1"
N/A
|
0507, 1"
N/A
|
Table 4 (Fujitsu SCSI)
Storage Cap
|
36 Gbyte
|
36 Gbyte
|
73 Gbyte
|
73 Gbyte
|
147 Gbyte
|
Vendor Nbr
|
MAP3367NC
|
MAS3367NC
|
MAP3735NC
|
MAS3735NC
|
MAP3147NC
|
F/W, size,
SE3310+ patch
|
0401, 1"
N/A
|
0101, 1"
N/A
|
0401, 1"
N/A
|
0101, 1"
N/A
|
0501, 1"
N/A
|
Table 4 (Hitachi SCSI)
Storage Cap
|
36 GBGbyte
|
73 Gbyte
|
147 Gbyte
|
Vendor Nbr
|
DK32EJ-36NC
|
DK32EJ-72NC
|
DK32EJ-14NC
|
F/W, size,
SE3310+ patch
|
PQ0B, 1"
N/A
|
PQ0B, 1"
N/A
|
PQ0B, 1"
N/A
|
NOTES
(a) Solaris 2.6 Operating system is supported on specific Sun servers using QLogic's native driver. Refer to the release notes for Sun StorEdge
3510 FC Array.
(c) The patches 103346, 109115, 109399, 109400, 109962 and 111853 do not appear in showrev -p. To see disc firmware revision levels you may use "luxadm inquiry /dev/rdsk/c[#-#]t*s2 | grep Rev"...
The FCode revision level for the SOC+ I/O System Board and the SOC+HA Sbus cards can be checked by "prtconf -vp | grep FCode".... or
you can look at the output of explorer script 2.2.3 or later, for both.....
(d) See table(s) 1 & 2...
(e) Prior to VxVM 3.0.2, all patches are for SEVM only, the Sun branded version of VxVM. The T3 is not supported prior to 3.0.2.
(f) Check the README file for dependencies on other patches... MPxIO/STMS requires Solaris 8, 04/01 or above.....and no its not planned to be
integrated into a future Solaris 8 update.... The product MPxIO has been
renamed STMS, StorEdge Traffic Management System.. Also, patch 111293 (latest) may be required for Solaris 8 and 9.
(g) 106429 (MM) is obsoleted by 105181. Also some SSA patches have now been moved into the kernel patch...
(h) Not required for the T3..
(j) Does not support the SSA...
(k) A5x00 support only...
(l) NT patch.
(m) This patch is necessary for those who use the LUXADM commands on the SSA...
(n) At this time we have six (6) FC controllers:
(1) Amber, 2200 PCI single channel output, 1.14.10, x6799A
(2) Crystal+, 2202 PCI dual channel output, 1.14.10, x6727A
(3) Crystal2A 2302 2Gb PCI dual channel output, 1.14.11, x6768A
(4) Diamond, 2202 Compact PCI dual channel output, 1.14.10, x6748A
(5) Ivory, 2200 2Gb Sbus dual channel output, 6757A, 1.14.05
(6) Amber2, 2300 2Gb PCI single channel output, 6767A, 1.14.11
(p) Minimum requirements are: 2.7 11/99 and Leadville patches or 2.8 6/00 and Leadville patches...
(q) T3+ has no Eprom code...
(r) Obsolete - Use StorTools 4.2.
(s) Firmware rev 0538/A538 is functionally equivalent to rev 0638/A638 respectively. Also, the most current disk FW must be installed after the
current T3 firmware patch. Refer to FCO A0199 for more details.
(v) Patch 114704 applies to IBM Fibre Channel drives for the T3/T3+ storage Array
(x) Starting with Solaris 9 and later, VxVM does not provide support for SSA.
(y) The most current disk firmware must be installed after the current T3 Patch is applied. May want to reference FCO A0199.
Date: Dec 13th, 2004 (Formerly Early Notifier 14838)
Internal Comments Further resources (e) Also see http://pts-storage.us.oracle.com/products/VM/patches.html for more VxVM patch details
matrix, storage, patch, firmware, photon Previously Published As 43212 Notes for Normalizaton: This document is referenced by:89031, 86544, 86541 Subset Root path: 43212-->89031-->89034-->89031-->89050/86520 Project: Minnow Normalization
Do you still have questions? You can use My Oracle Support Communities. Communities put you in touch with industry professionals like yourself. They are monitored by Oracle support engineers, so you can expect reliable and correct answers. Ask questions and see what others are asking about in the Disk Storage 2000, 3000, 6000 RAID Arrays & JBODs Community.
Attachments
This solution has no attachment
|