![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1002426.1 : Battery Replacement Procedure for Sun StorEdge 3310SCSI/3510FC/3511FC Arrays
PreviouslyPublishedAs 203394 Applies to:Sun Storage 3310 Array - Version Not Applicable and laterSun Storage 3510 FC Array - Version Not Applicable and later Sun Storage 3511 SATA Array - Version Not Applicable and later Sun Storage 3320 SCSI Array - Version Not Applicable and later All Platforms GoalThis document explains how to replace a failed (or expired) battery on a Sun StorEdge 3310 SCSI Array, 3320 SCSI Array, 3510 FC Array, or 3511 SATA Array. Refer to Chapter 4, Battery Fru, of the Sun StorEdge 3000 Family FRU Installation Guide. SolutionSteps to Follow1. Look at the battery LED before proceeding with replacement. The battery LED, is located on the controller module. There are 3 possible LED patterns.
2. Review the battery status in the telnet/tip interface as described in the Battery Status on Initial Firmware Screen of the Sun StorEdge 3000 Family FRU Installation Guide. 3. For the 3510 FC or 3511 SATA array, check the status using the show battery-status command from the sccli interface. sccli> show battery-status
Upper Battery Type: 1 Upper Battery Manufacturing Date: Tue Aug 12 12:41:24 2008 Upper Battery Placed In Service: Mon Sep 10 04:00:00 2008 Upper Battery Expiration Date: Sat Aug 12 06:41:24 2010 Upper Battery Expiration Status: Expired Lower Battery Type: 1 Lower Battery Manufacturing Date: Mon Mar 31 00:00:00 2008 Lower Battery Placed In Service: Wed Apr 8 04:00:00 2008 Lower Battery Expiration Date: Thu Mar 31 18:00:00 2010 Lower Battery Expiration Status: Expired
Status values include:
4. To replace the battery in a 3310 and 3320 SCSI Arrays, follow the FRU Replacement procedure for Replacing a SCSI Battery. 5. To replace the battery in a 3510-FC or 3511-SATA Array, follow the FRU Replacement procedure for Replacing an FC Battery. 6. For the 3510-FC or 3511-SATA array, set the in-service date via the sccli command, show battery -u. See FC Battery Status and In-Service Date. Example below. sccli> show battery-status -u
Upper Battery Type: 1 Upper Battery Manufacturing Date: Mon Feb 2 08:00:00 2004 Upper Battery Placed In Service: Wed Aug 11 20:18:02 2004 Upper Battery Expiration Date: Fri Aug 11 20:18:02 2006 Upper Battery Status: good The date 2004/9/29 will be stored as the In-Service Date of Lower Battery. Are you sure that this date is correct? y Lower Battery Type: 1 Lower Battery Manufacturing Date: Tue Mar 30 14:32:26 2004 Lower Battery Placed In Service: Wed Sep 29 21:04:39 2004 Lower Battery Expiration Date: Fri Sep 29 21:04:39 2006 Lower Battery Status: good
Do you still have questions? You can use My Oracle Support Communities. Communities put you in touch with industry professionals like yourself. They are monitored by Oracle support engineers, so you can expect reliable and correct answers. Ask questions and see what others are asking about in the Disk Storage 2000, 3000, 6000 RAID Arrays & JBODs Community.