In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Storage 3320 SCSI Array - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage 3310 Array - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Remove and Replace a SE3310/3320 EMU card

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)

Sun StorEdge 3000 Series Training or similar array experience

TASK COMPLEXITY: 1

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:

EMU card failed or defective.

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :


The EMU module is hot-swappable and can be replaced with the array powered on and without interrupting I/O.


WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Check for solid yellow (fault) LED on the EMU front panel.

2. Turn the thumbscrews on the top and bottom of the failed EMU module counterclockwise until the thumbscrews are disengaged from the chassis.

3. Hold the thumbscrews, and pullout the EMU module.

4. Slide the new EMU module into the chassis until it is firmly seated in the backplane and the module's front panel is flush with the chassis.

5. Turn the thumbscrews on the top and the bottom of the EMU module clockwise until they are finger-tight, to secure the module.

6. Check for a solid green LED on the new EMU front panel.

7. Using CLI (sccli), check EMU status:

sccli> show enclosure-status

EMU status example:

EMU 0 OK 370-5394 100149
EMU 1 OK 370-5394 100226

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

No further action needs to be taken.

PARTS NOTE:

REFERENCE INFORMATION:

Sun StorEdge Family 3000 Installation, Operation and Service Manual:
http://download.oracle.com/docs/cd/E19673-01/

Sun StorEdge Family 3000 FRU Installation Guides
3310: http://download.oracle.com/docs/cd/E19673-01/
3320: http://download.oracle.com/docs/cd/E19168-01/

TIME ESTIMATE: 20 minutes


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback