In this Document
Applies to:
Sun Storage 3511 SATA Array - Version Not Applicable and later
Sun Storage 3510 FC Array - Version Not Applicable and later
Sun Storage 3310 Array - Version Not Applicable and later
Sun Storage 3320 SCSI Array - Version Not Applicable and later
Information in this document applies to any platform.
Goal
This document identifies the procedures and documents required to update firmware on the Sun Storedge Series 3XX0 arrays. The includes models 3310, 3510, 3511 and 3320. Prior to any upgrade, the administrator (or technician) should completely familiarize themselves with the specific procedure detailed in the appropriate document.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
All procedures for firmware upgrades are provided within the Read Mefile of the patch. Use the latest version of the patch for your array type.
Other important references:
- Here is an internal matrix of the complete patch revision history. (In the event you are not upgrading to the latest firmware)
- This document does not cover the very specific firmware upgrade from 3.x to 4.x. You need to follow the special Firmware Migration Guide.
- This document does not cover the separate update of disk drive firmware.
- These patches explain how to update Raid code, SES code and PLD code for the 3510 and 3511.
- These patches explain how to update Raid code, and Safete code for the 3310 and 3320.
Prior to any scheduled upgrade, the Administrator (or technician) should have completed the following.
- Review of the appropriate Patch Read Me file for their specific array.
- The latest sscs software must be installed on the in-band data host that the array is servicing. See Document 1004352.1
- You need to be able to connect to the array with the sccli utility.
- The serial port (tip) cable should be installed and tested to verify you can connect to the console interface of the array.
Here is an overview of some of the critically important sccli command and outputs for the respective arrays being updated. Once again, the Readme file for each patch contains all the verbose details and instructions you will need.
For the 3510 and 3511
# sccli
sccli: selected device /dev/rdsk/c3t600C0FF0000000000013462AE47FC100d0s2 [SUN StorEdge 3510 SN#001346]
sccli> show redundancy
Primary controller serial number: 8014068
Primary controller location: Upper
Redundancy mode: Active-Active
Redundancy status: Enabled
Secondary controller serial number: 8012814
sccli> show inquiry
Vendor: SUN
Product: StorEdge 3510
Revision: 415F
Peripheral Device Type: 0x0
NVRAM Defaults: 415F 3510 S470F
Current NVRAM Version: 4.x
Bootrecord version: 1.31H
Serial Number: 001346
Page 80 Serial Number: 0013462AE47FC100
Page 83 Logical Unit Device ID: 600C0FF0000000000013462AE47FC100
Page 83 Target Device ID: 206000C0FF001346
IP Address: 10.152.224.101
Page D0 Fibre Channel Address: D3 (id 12)
Page D0 Node Name: 206000C0FF001346
Page D0 Port Name: 226000C0FFC01346
Ethernet Address: 00:C0:FF:00:13:46
Device Type: Primary
sccli> show ses
Ch Id Chassis Vendor/Product ID Rev PLD WWNN WWPN
-------------------------------------------------------------------------------
2 12 001346 SUN StorEdge 3510F A 1080 1000 204000C0FF001346 214000C0FF001346
Topology: loop(a)
3 12 001346 SUN StorEdge 3510F A 1080 1000 204000C0FF001346 224000C0FF001346
Topology: loop(b)
sccli>download controller-firmware SUN423A-3510.bin
sccli: Downloading controller firmware...programming flash memory...done
sccli: Engaging firmware...done
sccli>
sccli>download ses-firmware sesfw_3510_1106.s3r
For the 3310 and 3320
# sccli
sccli: selected device /dev/rdsk/c3t2d0s2 [SUN StorEdge 3310 SN#008482]
sccli> show redundancy-mode
Primary controller serial number: 8009328
Primary controller location: Lower
Redundancy mode: Active-Active
Redundancy status: Enabled
Secondary controller serial number: 8009200
sccli> show inquiry-data
Vendor: SUN
Product: StorEdge 3310
Revision: 411G
Peripheral Device Type: 0x0
NVRAM Defaults: 411G 3310 S415S
Bootrecord version: 1.31G
Serial Number: 000001
Page 80 Serial Number: 000001250FF1DC00
Page 83 Logical Unit Device ID: 600C0FF000000000000001250FF1DC00
IP Address: 206.1.111.111
Page D0 Target ID: 0
Ethernet Address: 00:C0:FF:80:00:01
Device Type: Primary
sccli> show safte
Ch Id Chassis Vendor Product ID Rev Package
---------------------------------------------------------
0 14 000187 SUN StorEdge 3310A 1159 1159
2 15 005632 SUN StorEdge 3310D 1159 1159
sccli> download controller-firmware SUN423C-3310.bin
WARNING: This is a potentially dangerous operation. The controller
will go offline for several minutes. Data loss may occur if the
controller is currently in use.
Are you sure? y
sccli: Downloading boot record...done
sccli: Downloading controller firmware...programming flash
memory...done
sccli: Engaging controller...done
sccli: /dev/rdsk/c0t5d0s2: device reset
sccli: /dev/rdsk/c0t5d0s2: waiting for device to be ready
sccli: /dev/rdsk/c0t5d0s2: device is ready
sccli> download safte-firmware saftefw_3310_1180.bin