Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle Network Applications Platform - Full Components List

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
System Notes:
This product is based on the Sun Netra 6000 Modular System, the Netra X3-2B Server Module,
Sun ZFS Storage 7320 and the Sun Disk Shelf 24 x 3.5" SAS-2, but only uses specific components.
Only use parts listed in the Oracle Network Applications Platform Full Components List to service this product.

Array Controller
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7053644 [C] 6Gbps SAS-2 Interface Module (SIM FW 3529) n/a
NOTE: 6Gbps SAS-2 Interface Module PN#7053644 is used in the Sun Disk Shelf 24 × 3.5" SAS-2 as part of the Oracle Network Applications Platform.
Backplane/Centerplane
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7068388 [F] PCI Express 2.0 Midplane Assembly (Netra 6000 M2, AC) n/a
  • 7045529
  • PCI Express 2.0 Midplane Assembly
n/a
    • 330-4398
    • Busbar Bolt Cover
n/a
    • 330-4399
    • Busbar Cover
n/a
    • 341-2337
    • Busbar
n/a
    • 341-3592
    • Busbar Spacer
n/a
    • 7045532
    • PCI Express 2.0 Midplane
n/a
Batteries
Option # Manufacturing
Part #
Description Previous
Part #
n/a 150-3993 [C] Buy 3V Lithium Coin Cell Battery n/a
Blade
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7049431 [F] Blade Motherboard Assembly n/a
  • 3V Lithium Coin Cell Battery
n/a
  • 530-3888
  • Hard Disk Drive Power Cable
n/a
  • 530-3993
  • HDD Data Cable, 150mm
n/a
  • 530-4555
  • HDD Data Cable, 370mm
n/a
  • 7046538
  • Blade Motherboard
n/a
  • 2-Slot 2.5" Disk Backplane
n/a
NOTE: Blade Motherboard Assembly PN#7049431 is used in the Netra X3-2B Server Module as part of the Oracle Network Applications Platform.
CPU Module
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4885 [F] 2.4GHz Intel Quad-Core Xeon E5620, 12MB, 80W n/a
n/a 541-2545 [F] Xeon Heatsink n/a
  • 240-6751
  • Spring Screw
n/a
  • 310-0161
  • Pre-greased Heatsink
n/a
n/a 7015351 [F] 2.1GHz Intel 8-Core Xeon E5-2658, 95W n/a
n/a 7020774 [F] Pre-Greased CPU Heatsink n/a
NOTE: 2.4GHz Intel Quad-Core Xeon E5620 PN#371-4885 is used in the Sun ZFS Storage 7320 as part of the Oracle Network Applications Platform.
NOTE: 2.1GHz Intel 8-Core Xeon E5-2658 PN#7015351 is used in the Netra X3-2B Server Module as part of the Oracle Network Applications Platform.
Cables
Option # Manufacturing
Part #
Description Previous
Part #
n/a 350-1519 [F] Buy Serial Cable Kit n/a
  • 530-4424
  • USB to DB9M Serial Cable
n/a
  • 530-4425
  • DB9F to DB9F Null Modem Cable
n/a
n/a 530-3100 RJ45F to DB9F Adapter n/a
n/a 530-3771 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 1m, Grey n/a
n/a 530-3880 [F] RJ45 to RJ45 Shielded Ethernet Cable, CAT5, 6M n/a
n/a 530-3883 [C] Buy 4X Mini SAS Cable, SFF-8088 to SFF-8088, 2M n/a
n/a 530-3884 [C] Buy 4X Mini SAS Cable, SFF-8088 to SFF-8088, 3M n/a
n/a 530-3888 Hard Disk Drive Power Cable n/a
n/a 530-3936 [C] USB/VGA/RJ45 Dongle Cable Adapter n/a
n/a 530-3993 HDD Data Cable, 150mm n/a
n/a 530-4435 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10' Black n/a
n/a 530-4436 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7' Black n/a
n/a 530-4480 [C] MPO to 4x LC Duplex Splitter Cable, 10m n/a
n/a 530-4526 [F] Buy Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7-Foot, Green n/a
n/a 530-4527 [F] Buy Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7-Foot, Yellow n/a
n/a 530-4555 HDD Data Cable, 370mm n/a
n/a 7015419 [F] 16A/250V 90° IEC 320 Sheet I to IEC 320 C19 Cord, 2M n/a
n/a 7061953 RJ45 to RJ45 Console Cable For Cisco Switch, 6' n/a
Communication
Option # Manufacturing
Part #
Description Previous
Part #
n/a 511-1496 Cluster Heartbeat Card n/a
NOTE: Cluster Heartbeat Card PN#511-1496 is used in the Sun ZFS Storage 7320 as part of the Oracle Network Applications Platform.
Disk Backplane
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7051678 [F] 8-Slot Disk Backplane, SATA DVD n/a
NOTE: 8-Slot Disk Backplane, SATA DVD PN#7051678 is used in the Sun ZFS Storage 7320 as part of the Oracle Network Applications Platform.
Disks
Option # Manufacturing
Part #
Description Previous
Part #
n/a 350-1574 Disk Shelf SSD Filler Panel n/a
n/a 541-4242 Disk Shelf HDD Filler Panel n/a
n/a 542-0423 [C] 600GB - 10000 RPM SAS SFF Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Hitachi HUC106060CSS600 [H106060SDSUN600G] (600GB - 10000 RPM - SAS Disk)
n/a
  • Seagate ST9600205SS [ST960005SSUN600G](600GB 10000 RPM SAS Disk)
n/a
  • Hitachi HUC109060CSS600 [H109060SESUN600G] (600GB - 10000 RPM - SAS Disk)
n/a
  • Marlin 2.5" Bracket
n/a
n/a 7010845 [C] 512GB Solid State SATA-2 Drive Assembly n/a
  • Toshiba THNSNC512GBSJ [Inquiry Unknown] (512GB - 2.5" Solid State - SATA-2 Disk)
n/a
  • Marlin 2.5" Bracket
n/a
n/a 7042768 2 [C] 500GB - 10000 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Western Digital WD5000BLHX [WD500BLHXSUN500G] (500GB - 10000 RPM - SATA Disk)
n/a
  • Marlin 2.5" Bracket
n/a
n/a 7047035 [C] 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST3600057SS [ST360057SSUN600G]
    (600GB - 15000 RPM - SAS Disk)
n/a
  • Hitachi HUS156060VLS600 [HUS1560SCSUN600G]
    (600GB - 15000 RPM - SAS Disk)
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7048983 [C] 73GB SAS-2 Solid State Drive Assembly n/a
  • Stec Z16IZF2E-73UCU [Inquiry Unknown] (73GB - 2.5" Solid State - SAS-2 Disk)
n/a
  • 2.5" Adapter
n/a
  • Left Bracket
n/a
  • Stingray 3.5" Mounting Bracket
n/a
2 The Western Digital 500GB 10000 RPM drive replaced the Seagate 500GB 7200 RPM drive due to shortages caused by flooding in Thailand in 2011. The bezel is labeled SATA 500GB 7200 RPM 3Gbps.
NOTE: 600GB - 10000 RPM SAS SFF Disk Assembly PN#542-0423 is used in the Netra X3-2B Server Module as part of the Oracle Network Applications Platform.
NOTE: 600GB - 15000 RPM SAS Disk Assembly PN#7047035 is used in the Sun Disk Shelf 24 × 3.5" SAS-2 as part of the Oracle Network Applications Platform.
NOTE: 73GB SAS-2 Solid State Drive Assembly PN#7048983 is used in the Sun Disk Shelf 24 × 3.5" SAS-2 as part of the Oracle Network Applications Platform.
NOTE: 512GB Solid State Drive SATA-2 Assembly PN#7010845 is used in the Sun ZFS Storage 7320 as part of the Oracle Network Applications Platform.
NOTE: 500GB - 10000 RPM SATA Disk Assembly PN#7042768 is used in the Sun ZFS Storage 7320 as part of the Oracle Network Applications Platform.
Ethernet
Option # Manufacturing
Part #
Description Previous
Part #
n/a 135-1203 [C] 1.25Gb/Sec Copper SFP Transceiver n/a
n/a 135-1204 [C] 10Gb/Sec QDR InfiniBand / 40Gb/Sec Ethernet QSFP Transceiver n/a
n/a 530-4449 [C] Buy 10Gb/Sec Short Wave SFP+ Transceiver n/a
n/a 7051223 [C] Dual 10-Gigabit PCI Express Ethernet SFP+ LP n/a
n/a 7051229 [C] Dual 10Gbps Ethernet Fabric Expansion Module (FEM) n/a
n/a 7053929 [C] 24-Port 10-Gigabit Ethernet Switched Network Express Module (NEM) n/a
n/a 7078195 [C] 24-Port 10-Gigabit Ethernet Switched Network Express Module (NEM) 7053929 [C]
n/a 7092924 [C] 24-Port 10-Gigabit Ethernet Switched Network Express Module (NEM) 7078195 [C] 
Fan
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-1446 [C] Rear Fan Controller Assembly n/a
  • 501-7377
  • Rear Fan Controller Board
n/a
n/a 371-4753 [C] Rear Fan Module (RFM) n/a
n/a 541-4274 [C] Fan Board Assembly n/a
  • 330-5274
  • Fan Deck
n/a
  • 511-1490
  • Fan Board
n/a
n/a 541-4276 [C] Fan Module n/a
  • 371-4789
  • 40x56mm, 15300 RPM Fan
n/a
NOTE: Rear Fan Controller Assembly PN#371-1446 is used in the Sun Netra 6000 AC M2 Modular System as part of the Oracle Network Applications Platform.
NOTE: Rear Fan Module (RFM) PN#371-4753 is used in the Sun Netra 6000 AC M2 Modular System as part of the Oracle Network Applications Platform.
I/O
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7049275 [C] 1-Slot x8 PCI Express Riser Assembly n/a
  • 541-2924
  • Riser Mounting Bracket
n/a
  • 7049274
  • 1-Slot x8 PCI Express Riser
n/a
    • 541-2924
    • Riser Mounting Bracket
n/a
n/a 7051681 [C] Connector Board Assembly, SATA DVD n/a
n/a 7053384 [C] 1-Slot x16 PCI Express Riser Assembly n/a
  • 541-2924
  • Riser Mounting Bracket
n/a
  • 7053383
  • 1-Slot x16 PCI Express Riser
n/a
Memory
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4966 [C] 8GB Registered DDR3L-1333/DDR3L-1600 DIMM, 1.35V n/a
n/a 371-5002 [C] 4GB USB 2.0 Flash Drive n/a
n/a 7041588 [C] 16GB Registered DDR3-1600 DIMM, 1.35V n/a
NOTE: 16GB Registered DDR3-1600 DIMM, 1.35V PN#7041588 is used in the Netra X3-2B Server Module as part of the Oracle Network Applications Platform.
NOTE: 8GB Registered DDR3L-1333/DDR3L-1600 DIMM, 1.35V PN#371-4966 is used in the Sun ZFS Storage 7320 as part of the Oracle Network Applications Platform.
NOTE: 4GB USB 2.0 Flash Drive PN#371-5002 is used in the Sun ZFS Storage 7320 as part of the Oracle Network Applications Platform.
Power
Option # Manufacturing
Part #
Description Previous
Part #
n/a 300-2276 [C] 764 Watt AC Input Power/Cooling Module n/a
n/a 300-2299 [C] Type A247A 760 Watt AC Input Power Supply n/a
n/a 511-1489 [F] Power Distribution Board n/a
n/a 7060590 [C] Type A251 5740 Watt AC Input Power Supply n/a
  • Power Supply Fan Tray
n/a
n/a 7081582 [C] Type A251 5740 Watt AC Input Power Supply n/a
  • Power Supply Fan Tray
n/a
NOTE: Type A247A 760 Watt AC Input Power Supply PN#300-2299 is used in the Sun ZFS Storage 7320 as part of the Oracle Network Applications Platform.
NOTE: Type A251 5740 Watt AC Input Power Supply PN#7060590 is used in the Sun Netra 6000 AC M2 Modular System as part of the Oracle Network Applications Platform.
NOTE: 764 Watt AC Input Power/Cooling Module PN#300-2276 is used in the Sun Disk Shelf 24 × 3.5" SAS-2 as part of the Oracle Network Applications Platform.
Rack
Option # Manufacturing
Part #
Description Previous
Part #
n/a 350-1531 Rackmount Kit n/a
  • n/a
  • Right Mounting Rail
n/a
  • n/a
  • Left Mounting Rail
n/a
n/a 350-1546 [C] Cable Management Arm 1U n/a
n/a 371-2741 [C] 1U/2U Screw-Mount Slide Rail Rackmount Kit, 730mm n/a
n/a 371-4919 [C] 1U/2U Screw-Mount Slide Rail Kit n/a
n/a 7015399 [F] 10A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 1M n/a
n/a 7015400 [F] 10A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 2M n/a
n/a 7051805 [F] 15KVA Single-Phase PDU, North America n/a
n/a 7051902 [F] 22KVA Single-Phase PDU, North America n/a
n/a 7051905 [F] 22KVA Single-Phase PDU, International n/a
n/a 7078657 [F] 15KVA Single-Phase PDU, North America 7051805 [F]
n/a 7078665 [F] 22KVA Single-Phase PDU, International 7051905 [F]
Removable Media
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2732 [C] USB Assembly n/a
  • 330-4418
  • DVD Tray
n/a
  • 341-4072
  • DVD Filler Panel
n/a
  • 501-7698
  • USB Board
n/a
SCSI
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7047851 [C] 6Gbps SAS-2 RAID Expansion Module (REM), B4 ASIC n/a
n/a 7050794 [C] 6Gbps SAS-2 RAID PCI Battery Module, BBU08 n/a
n/a 7056272 [C] 8-Port 6Gbps SAS-2 External RAID HBA n/a
Switch/Hub
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7023685 [F] Cisco Catalyst C4948E-F-S Switch with Fan & PSU n/a
  • 7024423 [F]
  • Cisco Catalyst C4948E-F 300 Watt AC Input Power Supply
n/a
  • 7024424 [F]
  • Cisco Catalyst C4948E-F Fan
n/a
System Board
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7049265 [F] System Board Assembly/FRU n/a
  • 7049264
  • System Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
System Service Processor
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7045545 [F] Chassis Management Module (CMM) Assembly n/a
  • Chassis Management Module (CMM) Board
n/a
n/a 7068397 [F] Chassis Management Module Assembly (Netra 6000 M2 AC & Netra 6000 M2 DC) n/a
  • 7068170 [F]
  • Chassis Management Module (CMM) Assembly
n/a
    • Chassis Management Module (CMM) Board
n/a

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Exploded View

No Artwork Currently Available

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown

Code Manufacturing Part# Description
2 371-1449 AC1/PS0-AC0 Internal Power Cord, 802mm
NS 263-4228 Netra 6000 Nameplate
NS 330-4342 Midplane Air Baffle
NS 371-1448 [C] Front Indicator Module
NS
  • 501-7378
  • LED Board Assembly
NS 371-1610 AC2/PS0-AC1 Internal Power Cord, 665mm
NS 371-1611 AC3/PS1-AC0 Internal Power Cord, 584mm
NS 371-1612 AC4/PS1-AC1 Internal Power Cord, 498mm
NS 371-1737 Network Express Module (NEM) Filler Panel
NS 371-3244 Chassis Subassembly
NS 371-3245 Mounting Rail Kit
NS 371-3610 Shipping Bracket Kit
NS 530-3927 [C] PDB to System Board Ribbon Cable
NS 530-4228 [C] SFF8087 to SFF8087 Mini-SAS Cable, 690mm
NS 530-4417 [C] 6-Pin Fan Power Cable
NS 530-4431 [C] Fan Data Ribbon Cable
NS 541-0729 PCI Express Express Module Filler Panel
NS
  • 341-1810
  • PCI Express Filler
NS 541-2075 [C] Bus Bar Set
NS
  • 341-3096
  • Long Red Bus Bar
NS
  • 341-3104
  • Short Blue Bus Bar
NS 7041264 [C] Disk Shelf Chassis Assembly
NS
  • 330-5203
  • Front Left End Cap
NS
  • 330-5204
  • Front Right End Cap
NS
  • 7041262
  • Centerplane Assembly
NS 7068384 N6000-AC M2 System Assembly
NS
  • 7068398
  • Chassis Assembly
NS
    • 7068166 [C]
    • Front Indicator Module
NS
    • 371-1448 [C]
    • Front Indicator Module
NS
      • 501-7378
      • LED Board Assembly
NS n/a AC Input Line Filter, Schurter C20F
  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.