Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Oracle Exadata X3-8 - Full Components List

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
System Notes:
This product is based on the Sun Server X3-2L / Sun Fire X4270 M3, Sun Server X4-2L and Sun Server X2-8 / Sun Fire X4800 M2 servers, but uses specialized components. Only use parts listed in the Exadata Database Machine X3-8 Full Components List to service this product.

Backplane/Centerplane
Option # Manufacturing
Part #
Description Previous
Part #
n/a 540-7640 [F] Midplane Assembly n/a
  • Signal Link Board
n/a
  • Busbar Assembly
n/a
  • Power Distribution Board
n/a
  • Centerplane
n/a
n/a 7049504 2 [F] Midplane Assembly 540-7640 [F]
  • Signal Link Board
n/a
  • Busbar Assembly
n/a
  • Midplane
n/a
  • Power Distribution Board
n/a
2 PN#7049504 (Midplane Assembly is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
NOTE: PN#540-7640 (Midplane Assembly is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
Batteries
Option # Manufacturing
Part #
Description Previous
Part #
n/a 150-1204 3 [F] 3V Lithium Coin Cell Battery n/a
n/a 150-3993 [F] Buy 3V Lithium Coin Cell Battery n/a
n/a 371-2210 [F] Buy 3V Lithium Coin Cell Battery n/a
3 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12
CPU Module
Option # Manufacturing
Part #
Description Previous
Part #
n/a 310-0225 [F] CPU Heatsink n/a
n/a 371-5057 [F] 2.4GHz Intel 10-core Xeon E7-8870, 130W n/a
n/a 7020776 [F] CPU Heatsink n/a
n/a 7026168 CPU Installation/Removal Tool n/a
n/a 7043559 [F] 2.0GHz Intel 6-core Xeon E5-2630L, 60W n/a
n/a 7069242 [F] 2.6GHz 6-Core Intel Xeon E5-2630 v2, 80W n/a
NOTE: PN#7043559 (2.0GHz Intel 6-core Xeon E5-2630L, 60W is used in the Sun Server X3-2L/Sun Fire X4270 M3 as part of the Oracle Exadata X3-8.)
NOTE: PN#310-0225 (CPU Heatsink is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
NOTE: PN#371-5057(2.4GHz Intel 10-core Xeon E7-8870, 130W is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
NOTE: PN#7020776 (CPU Heatsink is used in the Sun Server X3-2L/Sun Fire X4270 M3 as part of the Oracle Exadata X3-8.)
NOTE: PN#7069242 2.6GHz 6-Core Intel Xeon E5-2630 v2 is used in the Sun Server X4-2L as part of the Oracle Exadata X3-8.
Cables
Option # Manufacturing
Part #
Description Previous
Part #
n/a 250-2020 [F] Velcro Tape, 25 Yard Roll n/a
n/a 350-1519 [F] Buy Serial Cable Kit n/a
  • 530-4424
  • USB to DB9M Serial Cable
n/a
  • 530-4425
  • DB9F to DB9F Null Modem Cable
n/a
n/a 530-3100 RJ45F to DB9F Adapter n/a
n/a 530-3936 USB/VGA/RJ45 Dongle Cable Adapter n/a
n/a 530-4037 2-Slot 10-Pin Disk Backplane Power Cable n/a
n/a 530-4432 [F] Ethernet Cable, cat 5/5E, RJ45 to RJ45, 7' Blue n/a
n/a 530-4433 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10' Red n/a
n/a 530-4434 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7' Red n/a
n/a 530-4435 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10' Black n/a
n/a 530-4436 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7' Black n/a
n/a 530-4444 [F] Buy 10Gbps QSFP to QSFP Cable, 1m n/a
n/a 530-4445 [F] Buy 10Gbps QSFP to QSFP Cable, 3m n/a
n/a 530-4446 [F] Buy 10Gbps QSFP to QSFP Cable, 5m n/a
n/a 530-4502 [F] Buy Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10-Foot, Blue n/a
n/a 7014226 [F] Interlock Cable, 125mm n/a
n/a 7014930 Rear Disk Data Cable, SATA to 90° SATA, 400mm n/a
n/a 7014931 Rear Disk Data Cable, SATA to 90° SATA, 320mm n/a
n/a 7015654 4 Disk Data Cable, SFF-8087 to iPass+ HD, 203mm n/a
n/a 7046680 USB/VGA/RJ45 Dongle Cable Adapter 530-3936
n/a 7047257 [F] 12-Slot Backplane Cable Kit n/a
  • 530-4536
  • Disk Drive Flex Cable
n/a
  • 7014921
  • 4-Slot Disk Backplane Power Cable
n/a
  • 7015651
  • Disk Data Cable, iPass+ HD to iPass+ HD, 600mm
n/a
  • 7068329
  • Dual Backplane Power Cable
7014920
  • 7309765
  • Disk Drive Flex Cable
n/a
n/a 7061953 RJ45 to RJ45 Console Cable For Cisco Switch, 6' n/a
n/a 7071084 5 [F] Cable Clamp Kit n/a
4 FRU|CRU part 7014391 "SAS Expander Assembly" includes quantity 1 7015654 "Disk Data Cable".
5 Kit includes 28 cable clips and 14 alcohol wipes.
Chassis
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7310026 Left Ear Assembly n/a
Communication
Option # Manufacturing
Part #
Description Previous
Part #
n/a 375-3696 [F] Dual 40Gbps InfiniBand 4x QDR PCI Express Low Profile Host Channel Adapter n/a
n/a 375-3697 [F] Dual 40Gbps InfiniBand 4x QDR PCI Express ExpressModule Host Channel Adapter n/a
n/a 7046442 [F] Dual 40Gb/Sec (4x) QDR InfiniBand Host Channel Adapter Module M3 n/a
n/a 7092757 [F] Dual 40Gb/Sec (4x) QDR InfiniBand Host Channel Adapter Module M3 7046442 [F]
n/a 7092767 [F] Dual 40Gbps InfiniBand 4x QDR PCI Express Low Profile Host Channel Adapter 375-3696 [F]
NOTE: PN#7046442 Dual Port QDR CX3 Infiniband HCA is used in the Sun Server X4-2L as part of the Oracle Exadata X3-8.
Disk Backplane
Option # Manufacturing
Part #
Description Previous
Part #
7113575 12 x 8TB HDDs w/Disk Cage Upgrade Kit X-option
7317354 12 x 8TB 3.5" SAS3 HDDs w/Disk Cage Upgrade Kit n/a
  • 7301588 10 [F]
  • 8TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks:
n/a
    • Hitachi HUH728080AL5200 [H7280A520SUN8.0T] (8TB - 7200 RPM - SAS-3 Disk
n/a
    • Coral 3.5" Disk Drive Bracket
n/a
    • 3.5" Coral Disk Drive Bracket
n/a
  • 7310864
  • 12-Slot 3.5" Disk Cage Assembly
n/a
    • 341-7139
    • Right Ear Cover
n/a
    • 341-7140
    • Left Ear Cover
n/a
    • 7014929
    • LED Cable
n/a
    • Disk Backplane Right LED Indicator Module
n/a
      • 7023333
      • Right Indicator
n/a
    • 7027303
    • Front LED Indicator Module Cable
n/a
    • Disk Backplane Left LED Indicator Module
n/a
      • 7023335
      • Left Indicator
n/a
    • 7310503
    • 12-Slot 3.5" Disk Cage
n/a
      • 7310026
      • Left Ear Assembly
n/a
      • 7310027
      • Right Ear Assembly
n/a
      • 350-1812
      • Fan Door
n/a
    • 7313311 [F]
    • 4-Slot 3.5" Disk Backplane Assembly
n/a
      • 7084448
      • 3.5" Lightpipe Assembly
n/a
      • 7313312
      • 4-Slot Disk Backplane
n/a
n/a 511-1062 [F] 8-Slot Disk Backplane n/a
n/a 530-4214 [F] SAS0 HDD 2 Cable n/a
n/a 530-4215 [F] SAS1 HDD 0 Cable n/a
n/a 530-4216 [F] Backplane Power Cable n/a
n/a 7014920 Dual Backplane Power Cable n/a
n/a 7038979 12-Slot 3.5" Disk Cage Assembly n/a
  • 530-4037
  • 2-Slot 10-Pin Disk Backplane Power Cable
n/a
  • 541-4674
  • 2-Slot Rear Disk Cage Assembly
n/a
    • 7012767
    • Rear Disk Cage
n/a
    • 2-Slot Backplane
n/a
  • 7014930
  • Rear Disk Data Cable, SATA to 90° SATA, 400mm
n/a
  • 7014931
  • Rear Disk Data Cable, SATA to 90° SATA, 320mm
n/a
  • 7015651
  • Disk Data Cable, iPass+ HD to iPass+ HD, 600mm
n/a
  • 7015654 7
  • Disk Data Cable, SFF-8087 to iPass+ HD, 203mm
n/a
  • 12-Slot 3.5" Disk Cage Assembly
n/a
    • 341-7139
    • Right Ear Cover
n/a
    • 341-7140
    • Left Ear Cover
n/a
    • 530-4536
    • Disk Drive Flex Cable
n/a
    • SAS Expander Assembly
n/a
      • 7010672
      • SAS Expander Subassembly
n/a
        • 7023751
        • SAS Expander w/o Heatsink
n/a
      • 7015388
      • Plunger
n/a
      • 7015394
      • Grommet
n/a
    • 7014921
    • 4-Slot Disk Backplane Power Cable
n/a
    • 7014929
    • LED Cable
n/a
    • Disk Backplane Right LED Indicator Module
n/a
      • 7023333
      • Right Indicator
n/a
    • 4-Slot 3.5" Disk Backplane Assembly
n/a
      • 7014384
      • 3.5" Lightpipe Assembly
n/a
      • 4-Slot 3.5" Disk Backplane
n/a
      • 7049434
      • 3.5" Lightpipe Assembly
7014384
    • Disk Backplane Left LED Indicator Module
n/a
      • 7023335
      • Left Indicator
n/a
    • 7051157
    • 12-Slot 3.5" Disk Cage
n/a
      • 541-4671
      • Left Ear Assembly
n/a
      • 7051565
      • Right Ear Assembly
n/a
      • 7310026
      • Left Ear Assembly
n/a
      • 350-1812
      • Fan Door
n/a
    • 7068329
    • Dual Backplane Power Cable
7014920
    • 7309765
    • Disk Drive Flex Cable
n/a
n/a 7050690 9 [F] 8-Slot Disk Backplane 511-1062 [F]
n/a 7052898 [F] Left Ear Kit n/a
  • 7014929
  • LED Cable
n/a
  • Disk Backplane Left LED Indicator Module
n/a
    • 7023335
    • Left Indicator
n/a
n/a 7052899 [F] Right Ear Kit n/a
  • Disk Backplane Right LED Indicator Module
n/a
    • 7023333
    • Right Indicator
n/a
  • 7027303
  • Front LED Indicator Module Cable
n/a
6 Packaged FRU 7019623 includes 7023515 plus cables 7014930, 7014931, and 530-4037.
7 FRU|CRU part 7014391 "SAS Expander Assembly" includes quantity 1 7015654 "Disk Data Cable".
8 FRU|CRU part 7014391 includes a quantity of 1 7015654 "Disk Data Cable".
9 PN#7050690 (8-Slot Disk Backplane is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
10 The 8TB Disk is not supported in 12-Slot 3.5" Disk Cage Assembly 7077819. The 8TB Disk requires Disk Cage Assembly 7310384.
NOTE: PN#7038979 12-Slot 3.5" Disk Cage is used in the Sun Server X4-2L as part of the Oracle Exadata X3-8.
NOTE: PN#7023515 (2-Slot Backplane is used in the Sun Server X3-2L/Sun Fire X4270 M3 as part of the Oracle Exadata X3-8.)
NOTE: PN#511-1062 (8-Slot Disk Backplane is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
NOTE: PN#7027479 (4-Slot 3.5" Disk Backplane Assembly is used in the Sun Server X3-2L/Sun Fire X4270 M3 as part of the Oracle Exadata X3-8.)
Disks
Option # Manufacturing
Part #
Description Previous
Part #
n/a 542-0387 [F] 300GB - 10000 RPM, Disk Assembly with 1 bracket and 1 disk: n/a
  • Hitachi HUC106030CSS600 [H106030SDSUN300G] (300GB - 10000 RPM - SAS Disk)
n/a
  • Seagate ST9300605SS [ST930005SSUN300G](300GB 10000 RPM SAS Disk)
n/a
  • Hitachi HUC109030CSS600 [H109030SESUN300G] (300GB - 10000 RPM - SAS Disk)
n/a
  • Manta Ray 2.5" Bracket
n/a
n/a 542-0428 [F] 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST3600057SS [ST360057SSUN600G]
    (600GB - 15000 RPM - SAS Disk)
n/a
  • Hitachi HUS156060VLS600 [HUS1560SCSUN600G]
    (600GB - 15000 RPM - SAS Disk)
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
n/a 7010036 [F] 3TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST33000650SS [ST33000SSSUN3.0T] (3TB - 7200 RPM - SAS Disk)
n/a
  • Hitachi HUS723030ALS640 [H7230AS60SUN3.0T] (3TB - 7200 RPM - SAS Disk)
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
n/a 7066824 [F] 4TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Hitachi HUS724040ALS640 [H7240AS60SUN4.0T] (4TB - 7200 RPM - SAS Disk)
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
n/a 7070656 [F] 1.2TB - 10000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Hitachi HUC101212CSS600 [H101212SESUN1.2T] (1.2TB - 10000 RPM - SAS Disk)
n/a
  • Hitachi HUC101212CSS600 [H101212SESUN1.2T] (1.2TB - 10000 RPM - SAS Disk)
n/a
  • 2.5" Adapter
n/a
  • Left Bracket
n/a
  • 3.5" Drive Bracket
n/a
  • 3.5" Coral Disk Drive Bracket
n/a
n/a 7301588 11 [F] 8TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Hitachi HUH728080AL5200 [H7280A520SUN8.0T] (8TB - 7200 RPM - SAS-3 Disk
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
  • 3.5" Coral Disk Drive Bracket
n/a
n/a 7350770 [F] [A] 1.2TB 10000 RPM SAS-3 Disk Assembly without Encryption (EAEU part - see note below) n/a
  • HGST HUC101812CSS204 [H1018124FSUN1.2T] (1.2TB - 10000 RPM SAS Disk without Encryption) (EAEU part - see note below)
n/a
  • 2.5" Adapter
n/a
  • Left Bracket
n/a
  • 3.5" Drive Bracket
n/a
  • 3.5" Coral Disk Drive Bracket
n/a
n/a 7351735 [F] [A] 8.0TB - 7200 RPM SAS3 Disk Drive Assembly without Encryption (EAEU part - see note below) n/a
  • HGST HUH721008AL5204 [H7280B524SUN8.0T] (8.0TB - 7200 RPM SAS3 Disk without Encryption) (EAEU part - see note below)
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
  • 3.5" Coral Disk Drive Bracket
n/a
11 The 8TB Disk is not supported in 12-Slot 3.5" Disk Cage Assembly 7077819. The 8TB Disk requires Disk Cage Assembly 7310384.
NOTE: PN#7010036 (3TB - 7200 RPM SAS Disk Assembly is used in the Sun Server X3-2L/Sun Fire X4270 M3 as part of the Oracle Exadata X3-8.)
NOTE: PN#542-0428 (600GB - 15000 RPM SAS Disk Assembly is used in the Sun Server X3-2L/Sun Fire X4270 M3 as part of the Oracle Exadata X3-8.)
NOTE: PN#7070656 1.2TB 15000 RPM SAS Disk assembly is used in the Sun Server X4-2L as part of the Oracle Exadata X3-8.
NOTE: PN#7066824 4TB 7200 RPM SAS Disk Assembly is used in the Sun Server X4-2L as part of the Oracle Exadata X3-8.
NOTE: PN#542-0387 (300GB - 10000 RPM SAS Disk Assembly is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
Ethernet
Option # Manufacturing
Part #
Description Previous
Part #
n/a 375-3648 [F] Dual 10-Gigabit Ethernet Fabric Expansion Module (FEM) n/a
n/a 530-4449 [F] Buy 10Gb/Sec Short Wave SFP+ Transceiver n/a
n/a 540-7637 12 [F] Network Express Module (NEM) n/a
  • NEM Board
n/a
n/a 7049608 13 [F] Network Express Module (NEM) Assembly n/a
  • NEM Board
n/a
n/a 7051229 14 [F] Dual 10Gbps Ethernet Fabric Expansion Module (FEM) 375-3648 [F]
12 PN#540-7637 (NEM Assembly is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
13 PN#7049608 (NEM Assembly is used in the Sun Server X2-8/Sun Fire x4800 M2 as part of the Oracle Exadata X3-8.)
14 Dual 10Gbps Ethernet Fabric Expansion PN#7051229 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.
Fan
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4579 [F] Fan Assembly n/a
n/a 540-7672 [F] Fan Interconnect Module n/a
  • Fan Board
n/a
n/a 7045042 [F] Dual Counter Rotating Fan Module n/a
  • 7045041
  • 80×80mm Counter Rotating Fan
n/a
n/a 7061031 [F] Rear-to-Front Airflow Fan Module 350-1312 [F] [S]
n/a 350-1312 [F] [S] Rear-to-Front Airflow Fan Module n/a
NOTE: PN#7045042 (Dual Counter Rotating Fan Moduleis used in the Sun Server X3-2L/Sun Fire X4270 M3 as part of the Oracle Exadata X3-8.)
NOTE: PN#540-7672 (Fan Interconnect Module is used in the Sun Server X3-2L/Sun Fire X4270 M3 as part of the Oracle Exadata X3-8.)
NOTE: PN#371-4579 (Fan Assembly is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
Memory
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-5002 [F] 4GB USB 2.0 Flash Drive n/a
n/a 542-0434 [F] Qty 2 - 16GB 1.35V DDR3-1066 DIMMs (32GB Memory Assembly) n/a
  • 16GB 1.35V DDR3L-1066 DIMM (4-rank)
n/a
n/a 7018701 [F] 16GB DDR3-1600 DIMM, 1.35V n/a
n/a 7020486 [F] 8GB DDR3-1600 DIMM, 1.35V n/a
n/a 7059236 [F] 32GB Memory Assembly (2 × 16GB DDR3L-1600 DIMMs) n/a
  • 16GB 1.35V DDR3L-1600 DIMM (2-rank)
n/a
NOTE: PN#7018701 16GB DDR3-1600 1.35V Registered DIMM is used in the Sun Server X4-2L as part of the Oracle Exadata X3-8.
NOTE: PN#371-5002 (4GB USB 2.0 Flash Drive is used in the Sun Server X3-2L/Sun Fire X4270 M3 as part of the Oracle Exadata X3-8.)
NOTE: PN#7059236 32GB(2-Rank) Memory Assembly & PN#542-0434 32GB(4-Rank) Memory Assembly 32GB are used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.

NOTE: PN#7020486 (8GB DDR3-1600 DIMM, 1.35V is used in the Sun Server X3-2L/Sun Fire X4270 M3 as part of the Oracle Exadata X3-8.)
Power
Option # Manufacturing
Part #
Description Previous
Part #
n/a 300-2159 [F] Type A239 1030/2060 Watt AC Input Power Supply n/a
n/a 300-2299 [F] Type A247A 760 Watt AC Input Power Supply n/a
n/a 300-2321 [F] Type A239B 1030/2060 Watt AC Input Power Supply n/a
n/a 7044130 [F] Type A258 1000 Watt AC Input Power Supply n/a
n/a 7048276 15 [F] Type A239 2000 Watt AC Input Power Supply n/a
n/a 7060587 [F] Type A239D 1030/2060 Watt AC Input Power Supply 7048276 16 [F]
n/a 7065505 [F] Type A247B 760 Watt AC Input Power Supply n/a
15 PN#7048276 (Type A239 1030/2060 Watt AC Input Power Supply is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
16 PN#7048276 (Type A239 1030/2060 Watt AC Input Power Supply is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
NOTE: PN#300-2299 Type A247A 760 Watt AC Input Power Supply is also used in the Data Center InfiniBand Switch 36 as part of the Oracle Exadata X3-8.)
NOTE: PN#7044130 (A258 1000 Watt AC Input Power Supply is used in the Sun Server X3-2L/Sun Fire X4270 M3 as part of the Oracle Exadata X3-8.)
NOTE: PN#300-2321 (Type A239B 1030/2060 Watt AC Input Power Supply is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
NOTE: PN#300-2159 (Type A239 1030/2060 Watt AC Input Power Supply is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
Rack
Option # Manufacturing
Part #
Description Previous
Part #
n/a 180-2380 [F] 13A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 2M n/a
n/a 350-1287 [F] 1U/2U Cable Management Arm n/a
n/a 350-1580 1U Vented Filler Panel n/a
n/a 350-1626 Switch Mounting Rail n/a
n/a 350-1637 [F] 2 Way Service Upgrade Label (64x 267-4850) n/a
n/a 350-1638 [F] 3 Way Service Upgrade Label (96x 267-4850) n/a
n/a 350-1639 [F] 4 Way Service Upgrade Label (128x 267-4850) n/a
n/a 350-1640 [F] 5 Way Service Upgrade Label (160x 267-4850) n/a
n/a 350-1641 [F] 6 Way Service Upgrade Label (192x 267-4850) n/a
n/a 350-1642 [F] 7 Way Service Upgrade Label (224x 267-4850) n/a
n/a 350-1643 [F] 8 Way Service Upgrade Label (256x 267-4850) n/a
n/a 350-1662 [F] Rack Mount Kit n/a
  • 341-6410
  • Universal Rack Mount Bracket, M6 Holes
n/a
  • 341-6433
  • Rack Mount Bracket, Tapped Holes
n/a
  • 350-1644
  • Right Rack Mount Rail
n/a
  • 350-1645
  • Left Rack Mount Rail
n/a
n/a 350-1719 [F] 1U/2U Snap-In Slide Rail Rackmount Kit n/a
n/a 371-4510 [F] 24KVA Three-Phase PDU, North America n/a
n/a 371-4977 [F] 24KVA Three-Phase PDU, International n/a
n/a 371-5039 [F] 22KVA Single-Phase PDU, North America n/a
n/a 371-5040 [F] 22KVA Single-Phase PDU, International n/a
n/a 7015399 [F] 10A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 1M n/a
n/a 7015400 [F] 10A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 2M 180-2380 [F]
n/a 7042273 [F] 1U/2U Cable Management Arm (Snap-in) 350-1287 [F]
n/a 7046514 Single Snap-In Slide Rail n/a
n/a 7051902 [F] 22KVA Single-Phase PDU, North America 371-5039 [F]
n/a 7051905 [F] 22KVA Single-Phase PDU, International 371-5040 [F]
n/a 7051917 [F] 24KVA Three-Phase PDU, International 371-4977 [F]
n/a 7052216 [F] 24KVA Three-Phase PDU, North America 371-4510 [F]
n/a 7078665 [F] 22KVA Single-Phase PDU, International 7051905 [F] 
SCSI
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4982 [F] 6Gbps SAS-2 RAID PCI Battery Module, BBU08 n/a
n/a 375-3647 [F] 6Gbps SAS-2 RAID Expansion Module (REM), B2/B4 ASIC n/a
n/a 375-3701 [F] 8-Port 6Gbps SAS-2 RAID PCI Express HBA, B4 ASIC n/a
n/a 7014391 17 [F] SAS Expander Assembly n/a
  • 7010672
  • SAS Expander Subassembly
n/a
    • 7023751
    • SAS Expander w/o Heatsink
n/a
  • 7015388
  • Plunger
n/a
  • 7015394
  • Grommet
n/a
n/a 7026993 [F] Flash Accelerator F40 400GB Solid State Memory n/a
n/a 7047503 [F] 8-Port 6Gbps SAS-2 RAID PCI Express HBA, B4 ASIC 375-3701 [F]
n/a 7047851 [F] 6Gbps SAS-2 RAID Expansion Module (REM), B4 ASIC 375-3647 [F]
n/a 7060550 Universal Remote Battery Unit Upgrade n/a
  • 7056955
  • 1U Remote Battery Kit
n/a
    • 7059473
    • 1U Battery Backup Unit with Battery
n/a
      • 7055240
      • Remote Battery Adapter Board
n/a
      • 7056969
      • 1U Remote Battery Guide Tray
n/a
        • Remote Battery Backplane
n/a
        • 7056970
        • Remote Battery Guide Tray
n/a
        • 7056972
        • Remote Battery Cable, 930mm
n/a
      • 7057184 [F]
      • 1U/2U Remote Battery Assembly
n/a
        • 6Gbps SAS-2 RAID PCI Battery Module, BBU08
371-4982 [F]
        • Remote Battery Board
n/a
        • 7056966
        • Bezel and Rail Assembly
n/a
  • 7056956
  • 2U Remote Battery Kit
n/a
    • 7055240
    • Remote Battery Adapter Board
n/a
    • 7057184 [F]
    • 1U/2U Remote Battery Assembly
n/a
      • 6Gbps SAS-2 RAID PCI Battery Module, BBU08
371-4982 [F]
      • Remote Battery Board
n/a
      • 7056966
      • Bezel and Rail Assembly
n/a
    • 7060020 18 [F]
    • 2U Remote Battery Guide Assembly Kit
n/a
      • Remote Battery Backplane
n/a
      • 7056970
      • Remote Battery Guide Tray
n/a
      • 7056973
      • Remote Battery Cable, 600mm
n/a
n/a 7069200 [F] 800GB PCI Express Flash Accelerator F80 SAS HBA n/a
n/a 7070787 [F] Flash Accelerator F40 400GB Solid State Memory 7026993 [F]
17 FRU|CRU part 7014391 includes a quantity of 1 7015654 "Disk Data Cable".
18 When ordering the 2U Remote Battery Guide Assembly Kit PN#7060020, you actually receive Universal Remote Battery Unit Upgrade PN#7060550.
NOTE: PN#7069200 Flash Accelerator F80 800GB Solid State Memory is used in the Sun Server X4-2L as part of the Oracle Exadata X3-8.
NOTE: PN#7014391 (SAS Expander Assembly is used in the Sun Server X3-2L/Sun Fire X4270 M3 as part of the Oracle Exadata X3-8.)
Switch/Hub
Option # Manufacturing
Part #
Description Previous
Part #
n/a 310-0307 [F] Cooling Fan for Cisco Catalyst 4948 Switch n/a
n/a 371-4784 [F] Cisco Catalyst 4948 Switch n/a
n/a 371-4785 [F] Power Supply for Cisco Catalyst 4948 n/a
n/a 541-3495 Sun Datacenter InfiniBand Switch 36 Subassembly n/a
  • 350-1345
  • Fan Module Filler Panel, FT0 and FT4
n/a
  • 3V Lithium Coin Cell Battery
n/a
  • 511-1232
  • 36-Port QSFP Switch
n/a
    • 371-4596
    • Kontron nanoEXTexpress-SP Module
n/a
  • 511-1312
  • Fan Board
n/a
  • 530-4319
  • Internal Power Cable
n/a
  • 530-4320
  • Internal Signal Cable
n/a
n/a 7023685 [F] Cisco Catalyst C4948E-F-S Switch with Fan & PSU n/a
  • 7024423 [F]
  • Cisco Catalyst C4948E-F 300 Watt AC Input Power Supply
n/a
  • 7024424 [F]
  • Cisco Catalyst C4948E-F Fan
n/a
n/a 7052969 Data Center Infiniband Switch 36 n/a
  • Type A247A 760 Watt AC Input Power Supply
n/a
  • 350-1566 19
  • Rear-to-Front Airflow Fan Module
n/a
  • Datacenter Infiniband Switch 36 Subassembly
n/a
    • 350-1345
    • Fan Module Filler Panel, FT0 and FT4
n/a
    • 511-1312
    • Fan Board
n/a
    • 530-4319
    • Internal Power Cable
n/a
    • 530-4320
    • Internal Signal Cable
n/a
    • 7057247
    • 36-Port QSFP Switch
n/a
      • 3V Lithium Coin Cell Battery
n/a
      • 371-4596
      • Kontron nanoEXTexpress-SP Module
n/a
  • 7061031 [F]
  • Rear-to-Front Airflow Fan Module
350-1312 [F] [S]
  • Type A247B 760 Watt AC Input Power Supply
n/a
19 Fan 350-1566 is not a FRU (use 350-1312 or 7061031).
System Board
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-4586 [F] System Board Assembly (CMOD) n/a
  • 3V Lithium Coin Cell Battery
n/a
  • 0MB Board
n/a
n/a 7027349 Rear I/O Board n/a
n/a 7049382 [F] X3-2L System Board Assembly n/a
  • 350-1730
  • System Board Tray
n/a
  • 7023964
  • Pass Thru Mezzanine
n/a
  • 7046334
  • System Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
  • Rear I/O Board
7027349
n/a 7049498 20 [F] System Board Assembly (CMOD) 541-4586 [F]
  • 3V Lithium Coin Cell Battery
n/a
  • 0MB Board
n/a
n/a 7058152 [F] X4-2L System Board Assembly n/a
  • 350-1730
  • System Board Tray
n/a
  • 7023964
  • Pass Thru Mezzanine
n/a
  • 7046334
  • System Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
  • Rear I/O Board
7027349
20 PN#7049498 (System Board Assembly is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
NOTE: PN#7058152 System Board Assembly is used in the Sun Server X4-2L as part of the Oracle Exadata X3-8.
NOTE: PN#541-4586 (System Board Assembly is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)
NOTE: PN#7049382 (System Board Assembly is used in the Sun Server X3-2L/Sun Fire X4270 M3 as part of the Oracle Exadata X3-8.)
System Service Processor
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-4709 [F] Service Processor Module n/a
  • Service Processor Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
n/a 7045511 [F] Service Processor Module 541-4709 [F]
  • Service Processor Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
n/a 7060610 [F] Service Processor Module 7045511 [F] 
  • Service Processor Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
21 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12
22 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12
23 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12
NOTE: PNs#541-4709,7045511, and 7060610 (Service Processor Module is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X3-8.)

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Exploded View

No Artwork Currently Available

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown

Code Manufacturing Part# Description
NS 350-1288 DIMM Slot Filler
NS 350-1812 Fan Door
NS 371-4580 NEM Filler Panel
NS 541-0729 [F] PCI Express Express Module Filler Panel
NS
  • 341-1810
  • PCI Express Filler
NS 7057098 Exadata X4270 M3 Base Assembly
NS
  • 7051126
  • Sun Server X3-2L / X4270 M3 Base Assembly
NS
    • 7014540
    • Chassis Assembly
NS
      • 350-1677
      • Chassis Subassembly
NS
      • 350-1682
      • Rear Cover
NS
        • 150-4065
        • Interlock Switch Magnet
  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.