Oracle Exadata X2-8 - Full Components List

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
System Notes:
This product is based on the Sun Fire X4270 M2 and Sun Fire X4800 or Sun Server X2-8/Sun Fire X4800 M2 servers, but uses specialized components. Only use parts listed in the Oracle Exadata X2-8 Full Components List to service this product.

Backplane/Centerplane
Option # Manufacturing
Part #
Description Previous
Part #
n/a 540-7640 2 [F] Midplane Assembly n/a
  • Signal Link Board
n/a
  • Busbar Assembly
n/a
  • Power Distribution Board
n/a
  • Centerplane
n/a
n/a 7049504 4 [F] Midplane Assembly 540-7640 3 [F]
  • Signal Link Board
n/a
  • Busbar Assembly
n/a
  • Midplane
n/a
  • Power Distribution Board
n/a
2 Midplane Assembly PN#540-7640 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
3 Midplane Assembly PN#540-7640 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
4 Midplane Assembly PN#7049504 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
Batteries
Option # Manufacturing
Part #
Description Previous
Part #
n/a 150-1204 5 6 [F] 3V Lithium Coin Cell Battery n/a
n/a 150-3993 [F] Buy 3V Lithium Coin Cell Battery n/a
n/a 371-2210 7 [F] Buy 3V Lithium Coin Cell Battery n/a
5 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12
6 3V Lithium battery PN#150-1204 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
7 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267.
CPU Module
Option # Manufacturing
Part #
Description Previous
Part #
n/a 310-0225 8 [F] CPU Heatsink n/a
n/a 371-4860 [F] 2.26GHz 8-Core Xeon X7560 CPU Module n/a
n/a 371-4887 [F] 2.26GHz Intel 6-Core Xeon L5640, 12MB, 60W n/a
n/a 371-5057 9 [F] 2.4GHz Intel 10-core Xeon E7-8870, 130W n/a
n/a 371-5058 10 [F] 2.26GHz Intel 10-core Xeon E7-8860, 130W n/a
n/a 371-5059 11 [F] 2.13GHz Intel 8-core Xeon E7-8830, 105W n/a
n/a 541-3310 12 [F] Xeon Heatsink w/Grease n/a
  • 240-6751
  • Spring Screw
n/a
  • 310-0211
  • Pre-greased Heatsink
n/a
8 CPU Heatsink PN#310-0225 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
9 2.4GHz Intel 10-core Xeon E7-8870 PN#371-5057 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
10 2.26GHz Intel 10-core Xeon E7-8860 PN#371-5058 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
11 2.13GHz Intel 8-core Xeon E7-8830 PN#371-5059 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
12 Xeon Heatsink w/Grease PN#541-3310 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
Cables
Option # Manufacturing
Part #
Description Previous
Part #
n/a 350-1519 [F] Buy Serial Cable Kit n/a
  • 530-4424
  • USB to DB9M Serial Cable
n/a
  • 530-4425
  • DB9F to DB9F Null Modem Cable
n/a
n/a 530-3100 RJ45F to DB9F Adapter n/a
n/a 530-3936 USB/VGA/RJ45 Dongle Cable Adapter n/a
n/a 530-4403 [F] 4x QSFP 4x QSFP Copper QDR InfiniBand Cable, 2M n/a
n/a 530-4404 [F] 4x QSFP 4x QSFP Copper QDR InfiniBand Cable, 3M n/a
n/a 530-4415 [F] 4x QSFP 4x QSFP Copper QDR InfiniBand Cable, 5M n/a
n/a 530-4433 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10' Red n/a
n/a 530-4434 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7' Red n/a
n/a 530-4435 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10' Black n/a
n/a 530-4436 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7' Black n/a
n/a 530-4437 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10' Orange n/a
n/a 530-4438 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7' Orange n/a
n/a 530-4441 [F] Buy 10Gbps SFP+ TwinX Cable, 1m n/a
n/a 530-4442 [F] Buy 10Gbps SFP+ TwinX Cable, 3m n/a
n/a 530-4443 [F] Buy 10Gbps SFP+ TwinX Cable, 5m n/a
n/a 530-4444 [F] Buy 10Gbps QSFP to QSFP Cable, 1m n/a
n/a 530-4454 [F] 10Gbps SFP+ TwinX Cable, 10m n/a
n/a 560-2952 [F] Cable Kit n/a
  • 530-4245
  • 12-Slot Backplane Power Cable
n/a
  • 530-4458
  • 24-Slot Backplane Power Cable
n/a
  • 530-4459
  • 12/24-Slot Backplane Signal Cable
n/a
  • 530-4471
  • Fan Signal Cable
n/a
  • 530-4488
  • Fan Power Cable
n/a
n/a 7039990 [F] MPO to MPO High Bandwidth QSFP Optical Cable, 10M n/a
n/a 7039999 [F] MPO to MPO High Bandwidth QSFP Optical Cable, 20M n/a
n/a 7040001 [F] MPO to MPO High Bandwidth QSFP Optical Cable, 50M n/a
n/a 7046680 USB/VGA/RJ45 Dongle Cable Adapter 530-3936
Communication
Option # Manufacturing
Part #
Description Previous
Part #
n/a 375-3696 [F] Dual 40Gbps InfiniBand 4x QDR PCI Express Low Profile Host Channel Adapter n/a
n/a 375-3697 [F] Dual 40Gbps InfiniBand 4x QDR PCI Express ExpressModule Host Channel Adapter n/a
n/a 7092767 [F] Dual 40Gbps InfiniBand 4x QDR PCI Express Low Profile Host Channel Adapter 375-3696 [F]
Disk Backplane
Option # Manufacturing
Part #
Description Previous
Part #
n/a 511-1062 13 [F] 8-Slot Disk Backplane n/a
n/a 530-4214 [F] SAS0 HDD 2 Cable n/a
n/a 530-4215 [F] SAS1 HDD 0 Cable n/a
n/a 530-4216 [F] Backplane Power Cable n/a
n/a 541-4363 14 [F] 12-Slot 3.5" Disk Backplane Assembly n/a
  • 341-5083
  • Mounting Bracket
n/a
  • 12-Slot 3.5" Disk Backplane
n/a
n/a 7049238 16 17 [F] 12-Slot 3.5" Disk Backplane Assembly 541-4363 15 [F]
  • 341-5083
  • Mounting Bracket
n/a
  • 12-Slot 3.5" Disk Backplane
n/a
n/a 7050690 19 [F] 8-Slot Disk Backplane 511-1062 18 [F]
13 8-Slot Disk Backplane PN#511-1062 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
14 12-Slot Disk Backplane PN#541-4363 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
15 12-Slot Disk Backplane PN#541-4363 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
16 12-Slot Disk Backplane PN#7049238 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
17 12-Slot Disk Backplane PN#7049238 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
18 8-Slot Disk Backplane PN#511-1062 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
19 8-Slot Disk Backplane PN#7050690 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
Disks
Option # Manufacturing
Part #
Description Previous
Part #
7113576 12 x 8TB HDDs only Upgrade Kit X-option
7317324 12 x 8TB 3.5" SAS3 HDDs only Upgrade Kit n/a
n/a 542-0166 20 [F] 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST3600057SS [ST360057SSUN600G]
    (600GB - 15000 RPM - SAS Disk)
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
n/a 542-0247 21 [F] 2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST32000444SS [ST32000SSSUN2.0T] (2TB - 7200 RPM - SAS Disk)
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
n/a 542-0300 22 [F] 300GB - 10000 RPM, Disk Assembly with 1 bracket and 1 disk: n/a
  • Seagate ST9300603SS [ST930003SSUN300G]
    (300GB - 10000 RPM - SAS Disk)
n/a
  • Hitachi HUC103030CSS600 [H103030SCSUN300G]
    (300GB - 10000 RPM - SAS Disk)
n/a
  • Manta Ray 2.5" Bracket
n/a
n/a 542-0387 [F] 300GB - 10000 RPM, Disk Assembly with 1 bracket and 1 disk: n/a
  • Hitachi HUC106030CSS600 [H106030SDSUN300G] (300GB - 10000 RPM - SAS Disk)
n/a
  • Seagate ST9300605SS [ST930005SSUN300G](300GB 10000 RPM SAS Disk)
n/a
  • Hitachi HUC109030CSS600 [H109030SESUN300G] (300GB - 10000 RPM - SAS Disk)
n/a
  • Manta Ray 2.5" Bracket
n/a
n/a 542-0428 [F] 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST3600057SS [ST360057SSUN600G]
    (600GB - 15000 RPM - SAS Disk)
n/a
  • Hitachi HUS156060VLS600 [HUS1560SCSUN600G]
    (600GB - 15000 RPM - SAS Disk)
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
n/a 7010036 [F] 3TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST33000650SS [ST33000SSSUN3.0T] (3TB - 7200 RPM - SAS Disk)
n/a
  • Hitachi HUS723030ALS640 [H7230AS60SUN3.0T] (3TB - 7200 RPM - SAS Disk)
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
n/a 7040582 [F] 2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Hitachi HUS723020ALS640 [H7220AS60SUN2.0T] (2TB - 7200 RPM - SAS Disk)
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
n/a 7301588 23 [F] 8TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Hitachi HUH728080AL5200 [H7280A520SUN8.0T] (8TB - 7200 RPM - SAS-3 Disk
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
  • 3.5" Coral Disk Drive Bracket
n/a
n/a 7351735 [F] [A] 8.0TB - 7200 RPM SAS3 Disk Drive Assembly without Encryption (EAEU part - see note below) n/a
  • HGST HUH721008AL5204 [H7280B524SUN8.0T] (8.0TB - 7200 RPM SAS3 Disk without Encryption) (EAEU part - see note below)
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
  • 3.5" Coral Disk Drive Bracket
n/a
20 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks PN#542-0166 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
21 2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks PN#542-0247 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
22 300GB - 10000 RPM, Disk Assembly with 1 bracket and 1 disks PN#542-0300 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
23 The 8TB Disk is not supported in 12-Slot 3.5" Disk Cage Assembly 7077819. The 8TB Disk requires Disk Cage Assembly 7310384.
NOTE: 2TB Disk Assembly PN#F542-0247 is required if using Exadata image 11.2.2.4.0 or earlier. Refer to Note 1416303.1 for more details.
NOTE: 3TB Disk Assembly PN#7010036 requires a minimum Exadata image of 11.2.2.4.2 or later. Refer to Note 1416303.1 for more details.
NOTE: Using 2TB Disk Assembly PN#7040582 requires minimum Exadata image of 11.2.2.4.1 or later. Refer to Note 1416303.1 for more details.
NOTE: 600GB Disk Assembly PN#542-0166 is required if using Exadata image 11.2.2.4.0 or earlier. Refer to Note 1416303.1 for more details.
NOTE: Using 600GB Disk Assembly PN#542-0428 requires minimum Exadata image of 11.2.2.4.1 or later. Refer to Note 1416303.1 for more details.
Ethernet
Option # Manufacturing
Part #
Description Previous
Part #
n/a 135-1204 [F] 10Gb/Sec QDR InfiniBand / 40Gb/Sec Ethernet QSFP Transceiver n/a
n/a 375-3648 [F] Dual 10-Gigabit Ethernet Fabric Expansion Module (FEM) n/a
n/a 530-4449 [F] Buy 10Gb/Sec Short Wave SFP+ Transceiver n/a
n/a 540-7637 [F] Network Express Module (NEM) n/a
n/a 7049608 [F] Network Express Module (NEM) Assembly n/a
  • NEM Board
n/a
n/a 7051229 25 [F] Dual 10Gbps Ethernet Fabric Expansion Module (FEM) 375-3648 [F]
25 Dual 10Gbps Ethernet Fabric Expansion PN#7051229 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
Fan
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4579 26 [F] Fan Assembly n/a
n/a 540-7672 27 [F] Fan Interconnect Module n/a
  • Fan Board
n/a
n/a 541-4124 28 [F] Fan Board Assembly n/a
  • 330-5243
  • Fan Board Cover
n/a
  • Fan Board
n/a
n/a 541-4222 29 [F] Fan Assembly n/a
  • 371-4613
  • 60×28mm 10400/9500 RPM Dual Fan
n/a
n/a 7061031 [F] Rear-to-Front Airflow Fan Module 350-1312 [F] [S]
n/a 350-1312 [F] [S] Rear-to-Front Airflow Fan Module n/a
26 Fan Assembly PN#371-4579 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
27 Fan Interconnect Module PN#540-7672 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
28 Fan Board Assembly PN#541-4124 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
29 Fan Assembly PN#541-4222 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
I/O
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2884 30 [F] x8/x8 PCI Express Riser Assembly n/a
  • x8/x8 PCI Express Riser
n/a
  • 541-2531
  • Bracket
n/a
n/a 541-3356 31 [F] x8/x8 Switched PCI Express Riser Assembly n/a
  • x8/x8 Switched PCI Express Riser
n/a
  • 541-2531
  • Bracket
n/a
n/a 541-4306 [F] Connector Board Assembly n/a
  • Connector Board
n/a
  • 341-6222
  • Mounting Bracket
n/a
  • 530-3510
  • Interlock Switch Cable
n/a
n/a 7049269 33 [F] x8/x8 PCI Express Riser Assembly 541-2884 32 [F]
  • 541-2531
  • Bracket
n/a
  • 7049268
  • x8/x8 PCI Express Riser
501-7964
n/a 7049272 35 [F] x8/x8 Switched PCI Express Riser Assembly 541-3356 34 [F]
  • 541-2531
  • Bracket
n/a
  • 7049271
  • x8/x8 Switched PCI Express Riser
n/a
30 x8/x8 PCI Express Riser Assembly PN#541-2884 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
31 x8/x8 Switched PCI Express Riser Assembly PN#541-3356 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
32 x8/x8 PCI Express Riser Assembly PN#541-2884 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
33 x8/x8 PCI Express Riser Assembly PN#7049269 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
34 x8/x8 Switched PCI Express Riser Assembly PN#541-3356 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
35 x8/x8 Switched PCI Express Riser Assembly PN#7049272 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
Memory
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4743 [F] 4GB USB 2.0 Flash Drive n/a
n/a 371-4898 [F] 4GB Registered DDR3-1333 DIMM, 1.5V n/a
n/a 371-4965 [F] 4GB Registered DDR3-1333 DIMM, 1.35V n/a
n/a 542-0246 36 [F] Qty 2 - 8GB DIMMs (16GB Memory Assembly) n/a
  • 8GB DDR3/3L-1066/1333 DIMM
n/a
n/a 542-0434 [F] Qty 2 - 16GB 1.35V DDR3-1066 DIMMs (32GB Memory Assembly) n/a
  • 16GB 1.35V DDR3L-1066 DIMM (4-rank)
n/a
n/a 7011550 37 [F] 16GB Memory Assembly (2 × 8GB DDR3-1333 DIMMs) n/a
  • 8GB 1.35V DDR3L-1333 DIMM (2-rank)
n/a
n/a 7059236 [F] 32GB Memory Assembly (2 × 16GB DDR3L-1600 DIMMs) n/a
  • 16GB 1.35V DDR3L-1600 DIMM (2-rank)
n/a
36 2 × 8GB DIMMs PN#542-0246 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
37 16GB Memory Assembly PN#7011550 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
NOTE: 4GB Registered DDR3-1333 DIMM, 1.35V PN#371-4965 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
NOTE: 32GB Memory Assembly (2 × 16GB DDR3-1066 DIMMs) is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
PN#7059236 32GB(2-Rank) Memory Assembly or PN#542-0434 32GB(4-Rank) Memory Assembly".
NOTE: 4GB Registered DDR3-1333 DIMM, 1.5V PN#371-4898 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
Power
Option # Manufacturing
Part #
Description Previous
Part #
n/a 300-2143 38 [F] Type A237 760 Watt AC Input Power Supply n/a
n/a 300-2159 39 [F] Type A239 1030/2060 Watt AC Input Power Supply n/a
n/a 300-2233 [F] Type A247 760 Watt AC Input Power Supply 300-2143 40 [F]
n/a 300-2235 41 [F] Type A249 1100/1200 Watt AC Input Power Supply n/a
n/a 300-2299 [F] Type A247A 760 Watt AC Input Power Supply 300-2233 [F] 
n/a 300-2304 [F] Type A249A 1100/1200 Watt AC Input Power Supply 300-2235 43 [F]
n/a 541-4223 44 [F] Power Distribution Assembly n/a
  • 341-3166
  • Bus Bar Left
n/a
  • 341-3167
  • Bus Bar Right
n/a
  • Horizontal Power Distribution Board
n/a
  • Vertical Power Distribution Board
n/a
  • 371-2484
  • PDB Signal Cable
n/a
n/a 7048276 45 46 [F] Type A239 2000 Watt AC Input Power Supply n/a
n/a 7060587 [F] Type A239D 1030/2060 Watt AC Input Power Supply 7048276 47 48 [F]
n/a 7065505 [F] Type A247B 760 Watt AC Input Power Supply n/a
38 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
39 1030W/2060W AC Input Power Supply, Type A239 PN#300-2159 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
40 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
41 1200 Watt Power Supply, Type A249 PN#300-2235 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
42 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
43 1200 Watt Power Supply, Type A249 PN#300-2235 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
44 Power Distribution Assembly PN#541-4223 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
45 A239B 2000 Watt AC Input Power Supply PN#7048276 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
46 1030W/2060W AC Input Power Supply, Type A239 PN#7048276 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
47 A239B 2000 Watt AC Input Power Supply PN#7048276 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
48 1030W/2060W AC Input Power Supply, Type A239 PN#7048276 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
Rack
Option # Manufacturing
Part #
Description Previous
Part #
n/a 180-2379 [F] 13A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 1M n/a
n/a 180-2380 [F] 13A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 2M n/a
n/a 350-1287 [F] 1U/2U Cable Management Arm n/a
n/a 350-1502 [F] 1U/2U Bolt-In Slide Rail Kit n/a
n/a 350-1637 [F] 2 Way Service Upgrade Label (64x 267-4850) n/a
n/a 350-1638 [F] 3 Way Service Upgrade Label (96x 267-4850) n/a
n/a 350-1639 [F] 4 Way Service Upgrade Label (128x 267-4850) n/a
n/a 350-1640 [F] 5 Way Service Upgrade Label (160x 267-4850) n/a
n/a 350-1641 [F] 6 Way Service Upgrade Label (192x 267-4850) n/a
n/a 350-1642 [F] 7 Way Service Upgrade Label (224x 267-4850) n/a
n/a 350-1643 [F] 8 Way Service Upgrade Label (256x 267-4850) n/a
n/a 350-1662 [F] Rack Mount Kit n/a
  • 341-6410
  • Universal Rack Mount Bracket, M6 Holes
n/a
  • 341-6433
  • Rack Mount Bracket, Tapped Holes
n/a
  • 350-1644
  • Right Rack Mount Rail
n/a
  • 350-1645
  • Left Rack Mount Rail
n/a
n/a 371-4001 [F] 24KVA Three-Phase PDU, International n/a
n/a 371-4510 [F] 24KVA Three-Phase PDU, North America n/a
n/a 371-4742 [F] Universal Rack Mount Kit n/a
n/a 371-4977 [F] 24KVA Three-Phase PDU, International n/a
n/a 371-5039 [F] 22KVA Single-Phase PDU, North America n/a
n/a 371-5040 [F] 22KVA Single-Phase PDU, International n/a
n/a 7015399 [F] 10A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 1M 180-2379 [F]
n/a 7015400 [F] 10A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 2M 180-2380 [F]
n/a 7051905 [F] 22KVA Single-Phase PDU, International 371-5040 [F]
n/a 7051917 [F] 24KVA Three-Phase PDU, International 371-4977 [F]
n/a 7052216 [F] 24KVA Three-Phase PDU, North America 371-4510 [F]
SCSI
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4415 [F] 24GB Solid State Flash Memory Module n/a
n/a 371-4982 [F] 6Gbps SAS-2 RAID PCI Battery Module, BBU08 n/a
n/a 375-3647 [F] 6Gbps SAS-2 RAID Expansion Module (REM), B2/B4 ASIC n/a
n/a 375-3701 [F] 8-Port 6Gbps SAS-2 RAID PCI Express HBA, B4 ASIC n/a
n/a 541-3731 96GB PCI Express Flash Accelerator F20 SAS HBA n/a
  • Energy Storage Module (ESM)
n/a
  • PCI Express Flash Board
511-1275 [F] [S]
  • 24GB Solid State Flash Memory Module, FW D21Y
371-5014 [F] 
n/a 541-4417 49 96GB PCI Express Flash Accelerator F20 M2 1.1 SAS HBA n/a
  • Energy Storage Module (ESM) [SKU]
n/a
  • 24GB Solid State Flash Memory Module, FW D20Y
n/a
  • PCI Express Flash Board
n/a
n/a 7018497 [F] Energy Storage Module (ESM) (Qty #4) Kit [SKU] n/a
  • Energy Storage Module (ESM)
n/a
n/a 7018498 [F] Energy Storage Module (ESM) (Qty #12) Kit [SKU] n/a
  • Energy Storage Module (ESM)
n/a
n/a 7018499 [F] Energy Storage Module (ESM) (Qty #28) Kit [SKU] n/a
  • Energy Storage Module (ESM)
n/a
n/a 7047503 [F] 8-Port 6Gbps SAS-2 RAID PCI Express HBA, B4 ASIC 375-3701 [F]
n/a 7047851 [F] 6Gbps SAS-2 RAID Expansion Module (REM), B4 ASIC 375-3647 [F]
n/a 7050794 [F] 6Gbps SAS-2 RAID PCI Battery Module, BBU08 371-4982 [F]
n/a 7051731 [F] Energy Storage Module (ESM) (Qty #4) Kit [SKU] n/a
  • Energy Storage Module (ESM) [SKU]
n/a
n/a 7051732 [F] Energy Storage Module (ESM) (Qty #12) Kit [SKU] n/a
  • Energy Storage Module (ESM) [SKU]
n/a
n/a 7051733 [F] Energy Storage Module (ESM) (Qty #28) Kit [SKU] n/a
  • Energy Storage Module (ESM) [SKU]
n/a
49 The minimum OS image required to support F20 M2 is Exadata image patch update 11.2.2.3.2 or later.
NOTE: Energy Storage Module (ESM) Kits Quantity 4, 12, or 28, PN#7018497, PN#7018498 and PN#7018499 are used as a preventive maintenance kit only.
NOTE: For any Aura 1.0 cards failures PN#511-1275 or PN#511-1500 only replace with the Aura 1.1 card PN#541-4416 until further notice.
NOTE: Use the following Reference Doc to identify which Flash card is Installed in an Exadata Storage cell and order the correct FRU. See REFERENCE article 1416397.1.
Switch/Hub
Option # Manufacturing
Part #
Description Previous
Part #
n/a 310-0307 [F] Cooling Fan for Cisco Catalyst 4948 Switch n/a
n/a 371-4784 [F] Cisco Catalyst 4948 Switch n/a
n/a 371-4785 [F] Power Supply for Cisco Catalyst 4948 n/a
n/a 602-4758 Data Center InfiniBand Switch 36 n/a
  • Type A237 760 Watt AC Input Power Supply
n/a
  • Type A247 760 Watt AC Input Power Supply
300-2143 51 [F]
  • Type A247A 760 Watt AC Input Power Supply
300-2233 [F] 
  • 350-1312 [F] [S]
  • Rear-to-Front Airflow Fan Module
n/a
  • 350-1566 53
  • Rear-to-Front Airflow Fan Module
n/a
  • Sun Datacenter InfiniBand Switch 36 Subassembly
n/a
    • 350-1345
    • Fan Module Filler Panel, FT0 and FT4
n/a
    • 3V Lithium Coin Cell Battery
n/a
    • 511-1232
    • 36-Port QSFP Switch
n/a
      • 371-4596
      • Kontron nanoEXTexpress-SP Module
n/a
    • 511-1312
    • Fan Board
n/a
    • 530-4319
    • Internal Power Cable
n/a
    • 530-4320
    • Internal Signal Cable
n/a
n/a 7052969 Data Center Infiniband Switch 36 n/a
  • Type A247A 760 Watt AC Input Power Supply
300-2233 [F] 
  • 350-1566 56
  • Rear-to-Front Airflow Fan Module
n/a
  • Datacenter Infiniband Switch 36 Subassembly
n/a
    • 350-1345
    • Fan Module Filler Panel, FT0 and FT4
n/a
    • 511-1312
    • Fan Board
n/a
    • 530-4319
    • Internal Power Cable
n/a
    • 530-4320
    • Internal Signal Cable
n/a
    • 7057247
    • 36-Port QSFP Switch
n/a
      • 3V Lithium Coin Cell Battery
n/a
      • 371-4596
      • Kontron nanoEXTexpress-SP Module
n/a
  • 7061031 [F]
  • Rear-to-Front Airflow Fan Module
350-1312 [F] [S]
  • Type A247B 760 Watt AC Input Power Supply
n/a
n/a F541-3495 [F] Sun Datacenter InfiniBand Switch 36 [SKU] n/a
  • Sun Datacenter InfiniBand Switch 36 Subassembly
n/a
    • 350-1345
    • Fan Module Filler Panel, FT0 and FT4
n/a
    • 3V Lithium Coin Cell Battery
n/a
    • 511-1232
    • 36-Port QSFP Switch
n/a
      • 371-4596
      • Kontron nanoEXTexpress-SP Module
n/a
    • 511-1312
    • Fan Board
n/a
    • 530-4319
    • Internal Power Cable
n/a
    • 530-4320
    • Internal Signal Cable
n/a
50 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
51 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
52 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
53 Fan 350-1566 is not a FRU (use 350-1312 or 7061031).
54 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267.
55 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
56 Fan 350-1566 is not a FRU (use 350-1312 or 7061031).
57 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267.
58 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267.
System Board
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-3426 59 [F] System Board Assembly n/a
  • 511-1124
  • 0MB Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
n/a 541-4081 60 [F] System Board Assembly/FRU n/a
  • 511-1213
  • System Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
  • 541-2543
  • System Board Tray
n/a
n/a 541-4586 61 [F] System Board Assembly (CMOD) n/a
  • 3V Lithium Coin Cell Battery
n/a
  • 0MB Board
n/a
n/a 7049265 63 [F] System Board Assembly/FRU 541-4081 62 [F]
  • 7049264
  • System Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
n/a 7049498 65 [F] System Board Assembly (CMOD) 541-4586 64 [F]
  • 3V Lithium Coin Cell Battery
n/a
  • 0MB Board
n/a
59 System Board Assembly PN#541-3426 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
60 System Board Assembly/FRU PN#541-4081 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
61 System Board Assembly PN#541-4586 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
62 System Board Assembly/FRU PN#541-4081 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
63 System Board Assembly/FRU PN#7049265 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
64 System Board Assembly PN#541-4586 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
65 System Board Assembly PN#7049498 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
System Service Processor
Option # Manufacturing
Part #
Description Previous
Part #
n/a 540-7645 [F] Service Processor (SP) n/a
  • SP Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
n/a 541-4709 70 [F] Service Processor Module n/a
  • Service Processor Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
n/a 7045511 [F] Service Processor Module 541-4709 71 [F]
  • Service Processor Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
n/a 7060610 [F] Service Processor Module 7045511 [F] 
  • Service Processor Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
66 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12
67 3V Lithium battery PN#150-1204 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
68 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12
69 3V Lithium battery PN#150-1204 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
70 Service Processor Module PN#541-4709 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
71 Service Processor Module PN#541-4709 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
72 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12
73 3V Lithium battery PN#150-1204 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
74 Service Processor Module PN#541-4709 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
75 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12
76 3V Lithium battery PN#150-1204 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
NOTE: Service Processor Module PNs#540-7645, 7045511, and 7060610 are used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Exploded View

No Artwork Currently Available

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown

Code Manufacturing Part# Description
NS 341-6222 Mounting Bracket
NS 371-2484 PDB Signal Cable
NS 530-3510 Interlock Switch Cable
NS 530-3892 77 [F] 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 670mm
NS 530-3927 [F] PDB to System Board Ribbon Cable
NS 541-2075 [F] Bus Bar Set
NS
  • 341-3096
  • Long Red Bus Bar
NS
  • 341-3104
  • Short Blue Bus Bar
NS 541-4304 78 [F] Right Indicator Panel
NS
  • 530-4244
  • Indicator Cable
NS
  • 530-4463
  • LED/USB Flex Cable
NS 541-4305 79 [F] SAS Expander Assembly
NS
  • 330-5300
  • Mounting Bracket
NS
  • SAS Expander
NS 541-4371 80 [F] Left Indicator Panel
NS
  • 511-1594
  • LED Board
NS
  • 530-4478
  • Left Indicator Cable
NS 7055798 82 [F] SAS Expander Assembly
NS
  • 541-4305 81 [F]
  • SAS Expander Assembly
NS
  • 330-5300
  • Mounting Bracket
NS
  • SAS Expander
77 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 670mm PN#530-3892 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
78 Right Indicator Panel PN#541-4304 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
79 SAS Expander Assembly PN#541-4305 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
80 Left Indicator Panel PN#541-4371 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
81 SAS Expander Assembly PN#541-4305 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
82 SAS Expander Assembly PN#7055798 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.