[F] = Field Replaceable Unit (FRU) [C] = Customer Replaceable Unit (CRU) [A] = Alternate, can be used in system; wasn't used during production [S] = Supported, but can no longer be ordered with this system [N] = No longer supported for this system Price = Price this Part
System Notes:
This product is based on the Sun Fire X4270 M2 and Sun Fire X4800 or Sun Server X2-8/Sun Fire X4800 M2 servers, but uses specialized components. Only use parts listed in the Oracle Exadata X2-8 Full Components List to service this product.
2 Midplane Assembly PN#540-7640 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 3 Midplane Assembly PN#540-7640 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 4 Midplane Assembly PN#7049504 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
5 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12 6 3V Lithium battery PN#150-1204 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 7 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267.
8 CPU Heatsink PN#310-0225 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 9 2.4GHz Intel 10-core Xeon E7-8870 PN#371-5057 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8. 10 2.26GHz Intel 10-core Xeon E7-8860 PN#371-5058 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8. 11 2.13GHz Intel 8-core Xeon E7-8830 PN#371-5059 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8. 12 Xeon Heatsink w/Grease PN#541-3310 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
13 8-Slot Disk Backplane PN#511-1062 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 14 12-Slot Disk Backplane PN#541-4363 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 15 12-Slot Disk Backplane PN#541-4363 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 16 12-Slot Disk Backplane PN#7049238 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 17 12-Slot Disk Backplane PN#7049238 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 18 8-Slot Disk Backplane PN#511-1062 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 19 8-Slot Disk Backplane PN#7050690 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
20 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks PN#542-0166 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 21 2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks PN#542-0247 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 22 300GB - 10000 RPM, Disk Assembly with 1 bracket and 1 disks PN#542-0300 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 23 The 8TB Disk is not supported in 12-Slot 3.5" Disk Cage Assembly 7077819. The 8TB Disk requires Disk Cage Assembly 7310384. NOTE: 2TB Disk Assembly PN#F542-0247 is required if using Exadata image 11.2.2.4.0 or earlier. Refer to Note 1416303.1 for more details. NOTE: 3TB Disk Assembly PN#7010036 requires a minimum Exadata image of 11.2.2.4.2 or later. Refer to Note 1416303.1 for more details. NOTE: Using 2TB Disk Assembly PN#7040582 requires minimum Exadata image of 11.2.2.4.1 or later. Refer to Note 1416303.1 for more details. NOTE: 600GB Disk Assembly PN#542-0166 is required if using Exadata image 11.2.2.4.0 or earlier.
Refer to Note 1416303.1 for more details. NOTE: Using 600GB Disk Assembly PN#542-0428 requires minimum Exadata image of 11.2.2.4.1 or later.
Refer to Note 1416303.1 for more details.
26 Fan Assembly PN#371-4579 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 27 Fan Interconnect Module PN#540-7672 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 28 Fan Board Assembly PN#541-4124 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 29 Fan Assembly PN#541-4222 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
30 x8/x8 PCI Express Riser Assembly PN#541-2884 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 31 x8/x8 Switched PCI Express Riser Assembly PN#541-3356 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 32 x8/x8 PCI Express Riser Assembly PN#541-2884 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 33 x8/x8 PCI Express Riser Assembly PN#7049269 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 34 x8/x8 Switched PCI Express Riser Assembly PN#541-3356 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 35 x8/x8 Switched PCI Express Riser Assembly PN#7049272 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
36 2 × 8GB DIMMs PN#542-0246 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 37 16GB Memory Assembly PN#7011550 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8. NOTE: 4GB Registered DDR3-1333 DIMM, 1.35V PN#371-4965 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. NOTE: 32GB Memory Assembly (2 × 16GB DDR3-1066 DIMMs) is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
PN#7059236 32GB(2-Rank) Memory Assembly or PN#542-0434 32GB(4-Rank) Memory Assembly". NOTE: 4GB Registered DDR3-1333 DIMM, 1.5V PN#371-4898 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.
38 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267. 39 1030W/2060W AC Input Power Supply, Type A239 PN#300-2159 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 40 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267. 41 1200 Watt Power Supply, Type A249 PN#300-2235 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 42 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267. 43 1200 Watt Power Supply, Type A249 PN#300-2235 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 44 Power Distribution Assembly PN#541-4223 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 45 A239B 2000 Watt AC Input Power Supply PN#7048276 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8. 46 1030W/2060W AC Input Power Supply, Type A239 PN#7048276 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 47 A239B 2000 Watt AC Input Power Supply PN#7048276 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8. 48 1030W/2060W AC Input Power Supply, Type A239 PN#7048276 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8.
49 The minimum OS image required to support F20 M2 is Exadata image patch update 11.2.2.3.2 or later. NOTE: Energy Storage Module (ESM) Kits Quantity 4, 12, or 28, PN#7018497, PN#7018498 and PN#7018499 are used as a preventive maintenance kit only. NOTE: For any Aura 1.0 cards failures PN#511-1275 or PN#511-1500 only replace with the Aura 1.1 card PN#541-4416 until further notice. NOTE: Use the following Reference Doc to identify which Flash card is Installed in an Exadata
Storage cell and order the correct FRU.
See REFERENCE article 1416397.1.
50 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267. 51 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267. 52 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267. 53 Fan 350-1566 is not a FRU (use 350-1312 or 7061031). 54 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267. 55 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267. 56 Fan 350-1566 is not a FRU (use 350-1312 or 7061031). 57 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267. 58 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267.
59 System Board Assembly PN#541-3426 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 60 System Board Assembly/FRU PN#541-4081 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 61 System Board Assembly PN#541-4586 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8. 62 System Board Assembly/FRU PN#541-4081 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 63 System Board Assembly/FRU PN#7049265 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 64 System Board Assembly PN#541-4586 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8. 65 System Board Assembly PN#7049498 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
66 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12 67 3V Lithium battery PN#150-1204 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 68 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12 69 3V Lithium battery PN#150-1204 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 70 Service Processor Module PN#541-4709 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8. 71 Service Processor Module PN#541-4709 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8. 72 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12 73 3V Lithium battery PN#150-1204 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. 74 Service Processor Module PN#541-4709 is used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8. 75 Field Engineers should stock this part and not have them shipped from Oracle stocking locations. See Global Systems TSC communication dated 10/12/12 76 3V Lithium battery PN#150-1204 is used in the Sun Fire X4800 as part of the Oracle Exadata X2-8. NOTE: Service Processor Module PNs#540-7645, 7045511, and 7060610 are used in the Sun Server X2-8/Sun Fire X4800 M2 as part of the Oracle Exadata X2-8.
Table Legend
[F] = Field Replaceable Unit (FRU) [C] = Customer Replaceable Unit (CRU) [A] = Alternate, can be used in system; wasn't used during production [S] = Supported, but can no longer be ordered with this system [N] = No longer supported for this system Price = Price this Part
[F] = Field Replaceable Unit (FRU) [C] = Customer Replaceable Unit (CRU) [A] = Alternate, can be used in system; wasn't used during production [S] = Supported, but can no longer be ordered with this system [N] = No longer supported for this system Price = Price this Part
NS = Not Shown
Code
Manufacturing Part#
Description
NS
341-6222
Mounting Bracket
NS
371-2484
PDB Signal Cable
NS
530-3510
Interlock Switch Cable
NS
530-3892 77 [F]
4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 670mm
77 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 670mm PN#530-3892 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 78 Right Indicator Panel PN#541-4304 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 79 SAS Expander Assembly PN#541-4305 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 80 Left Indicator Panel PN#541-4371 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 81 SAS Expander Assembly PN#541-4305 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8. 82 SAS Expander Assembly PN#7055798 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata X2-8.